• 제목/요약/키워드: Hydrogen exchange

검색결과 408건 처리시간 0.031초

뱀장어(Anguilla japonica) 추출 Carnosine이 과산화수소로 유도된 인체 백혈구의 DNA 손상과 Repair에 미치는 효과 (The Effect of Carnosine Extracted from Eels Anguilla japonica on Oxidative DNA Damage Induced by Hydrogen Peroxide and the DNA Repair Capacity of Human Leukocytes)

  • 송호수
    • 한국수산과학회지
    • /
    • 제50권5호
    • /
    • pp.520-526
    • /
    • 2017
  • Carnosine was recently reported to protect against the DNA damage induced by oxidative stress. In this study, we investigated the protective effect of eel Anguilla japonica carnosine extracts prepared using different methods (heat treatment extracts, HTEs; ion exchange chromatography, IEC; ultrafiltration permeation, UFP) on leukocyte DNA damage using the comet assay. Human leukocytes were incubated with extracts of eel carnosine at concentrations (of 10, 50, $100{\mu}g/mL$), and then subjected to an oxidative stimulus [$200{\mu}M$ hydrogen peroxide ($H_2O_2$)]. Pretreatment of the cells for 30 min with carnosine significantly reduced the genotoxicity of $H_2O_2$ measured as DNA strand breaks. The protective effects of the three types of extract (HTE, IEC, and UFP) increased with concentration. At the highest concentration (100 g/mL). there were no statistical differences in oxidative damage between each extract treatment and PBS-treated negative controls. When leukocytes were incubated with carnosine for 30 min after exposure to $H_2O_2$. the protective ability of each extract changed. Therefore, eel carnosine inhibits the $H_2O_2$ induced damage to cellular DNA in human leukocytes, supporting the protective effect of this compound against oxidative damage.

새우 양식장에 적용을 위한 저질개선 평가 (Evaluation of Improvement on Sediment for Practical Application in Prawn Farm)

  • 김우항;김도희
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 춘계학술발표회
    • /
    • pp.81-84
    • /
    • 2004
  • Control of Sediment is very important in prawn farm due to the eruption of toxic material such as W1ionized H2S, NH3 and NO2-. In this study, column test study, column with filter media such as activated carbon, zeolite, oyster shell and iron chloride to evaluate the reduction of toxicity from sediment ammonia-N(NH3) was effectively removed by Zeolite and oyster shell. It was indicated that ammonium ion(NH4+) was removed by ion exchange of zeolite. And the ammonia in the column of oyster shell was existed as the form of NH4+, which is not toxic for prawn because oyster shell was stably kept around pH 8. Therefore, some of ammonia(NH3) was reduced by oyster shell. Hydrogen sulfide and COD were effectively removed by adsorption of activated carbon and a partial removal of hydrogen sulfide was accomplished by Oyster shell. Phosphorous was removed by activated carbon, oyster shell and iron chloride. In prawn farm, the concentration of ammonia was increased with increase of pH by algae photosynthesis in the column of activated carbon, zeolite and iron chloride, but it was revealed that pH was stably kept in the column of oyster shell.

  • PDF

전바나듐계 레독스플로우전지용 집전체에 대한 연구 (Study on Current Collector for All Vanadium Redox Flow Battery)

  • 최호상;황갑진;김재철;유철휘
    • 한국수소및신에너지학회논문집
    • /
    • 제22권2호
    • /
    • pp.240-248
    • /
    • 2011
  • All-vanadium redox flow battery (VRFB) has been studied actively as one of the most promising electrochemical energy storage systems for a wide range of applications such as electric vehicles, photovoltaic arrays, and excess power generated by electric power plants at night time. Among consisting elements of the VRFB, the ion exchange membrane and the electrode play important roles. In this study, carbon PVC coposite sheets for the VRFB have been developed and electrochemical characteristics investigated. Current collector for VRFB, carbon PVC composite sheets (CPCS), were prepared with G-1028 as a conducting particle, PVC as a polymer, Dibutyl phthalate (DBP) as a plasticizer and fumed Silica (FS) as a dispersion agent. CPCS has been shown to have the characteristics as an excellent current collector for VRFB and electrochemical properties of specific resistivity 0.31 ${\Omega}cm$, which were composed of G-1028 80 wt%, PVC 10 wt%, DBP 5 wt% and FS 5 wt%.

혼합 다채널 사형 유로의 혼합영역이 PEMFC 성능에 미치는 영향 (The Effect of Mixing Region in Mixed Multiple Serpentine Flow-field to PEMFC Performance)

  • 이지홍;이명용;김헌주;이상석;이도형
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.265-273
    • /
    • 2009
  • Proton Exchange Membrane Fuel Cell (PEMFC) has low operating temperature and high efficiency. And PEMFC consists of many components as bipolar plate, gas diffusion layer, membrane etc.. Flow-field in bipolar plate roles path for transporting reactants to membrane. Therefore a design of flow-field has an effect on PEMFC's performance. In this study, Computational Fluid Dynamics (CFD) simulations were performed for comparing mixed multiple serpentine (MMS) flow-field and multiple serpentine (MS) flow-field. And we studied an effect according to change mixing region design in MMS flow-field. Finally the applicability of results is verified by performing CFD simulation about fixed MMS flow-field which is combined good designs.

고분자전해질 연료전지 Dead-end 운전 최적화에 대한 실험적인 연구 (Experimental Analysis for Optimization of PEM Fuel Cell Dead-end Operation)

  • 이봉구;손영준
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.136-147
    • /
    • 2015
  • Dead-ended operation of Proton Exchange Membrane Fuel Cell(PEMFC) provides the simplification of fuel cell systems to reduce fuel consumption and weight of fuel cell. However, the water accumulation within the channel prohibits a uniform supply of fuel. Optimization of the purge strategy is required to increase the fuel cell efficiency since fuel and water are removed during the purge process. In this study, we investigated the average voltage output which depends on two interrelated conditions, namely, the supply gas pressure, purging valve open time. In addition, flow visualization was performed to better understand the water build-up on the anode side and cathode side of PEMFC in terms of a variety of the current density. We analyzed the correlation between the purge condition and water flooding.

이온 교환막 연료전지용 막 가습기의 물질전달 성능 실험 (Experimental Analysis of Mass Transfer Capability of Membrane Humidifier for PEMFC)

  • 탁현우;김경택;임석연;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.19-25
    • /
    • 2012
  • The efficiency and life time of the Proton Exchange Membrane fuel cell (PEMFC) system is critically affected by incoming gas with humidity which should be maintained properly at normal operating conditions. Typically, incoming gas of automotive fuel cell is humidified by external humidifier but the characteristics of device is rarely reported. In this study, characteristics of water transfer in the membrane humidifiers have been experimentally investigated for flow rates of gas and for different flow arrangement under steady state condition. At first, capability of mass transfer through the membrane is examined at constant temperature. Then, the temperature distribution effect on the capability of mass transfer is tested over various inlet conditions. In summary, this research presents the mass transfer capability of hydrophilic membrane over various operating conditions.

부타디엔 고무로 결합된 탄소반죽 바이오센서를 이용한 과산화수소의 전기화학적 정량 (Electrochemical determination of hydrogen peroxide using carbon paste biosensor bound with butadiene rubber)

  • 윤길중
    • 분석과학
    • /
    • 제23권5호
    • /
    • pp.505-510
    • /
    • 2010
  • 톨루엔에 녹인 폴리부타디엔을 탄소가루의 결합재로 사용하였을 때, 탄소반죽은 전극 제작 후 용매 증발에 의하여 기계적 물성을 보였으며, 이 성질은 탄소반죽전극 실용화의 선행조건을 충족시키는 것이었다. 부타디엔 고무를 결합재로 사용하여 새로운 효소전극을 제작하고, 그것이 정량적인 전기화학적 행동을 보이는지 확인하기 위하여 여러 가지 전기화학 속도론적 파라메터 즉 대칭인자, 교환전류밀도, 이중층의 축전용량, 시간상수, 최대전류, Michaelis 상수 등을 구하였다. 이 결과들은 부타디엔 고무가 탄소반죽전극 실용화에 추천할 만한 위한 결합재임을 보여 주는 것이었다.

Cathode에 따른 소형 PEM 연료전지의 성능 변화 (Performance of the Small PEMFC according to Cathode)

  • 이세원;이강인;박민수;주종남
    • 한국수소및신에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.283-290
    • /
    • 2008
  • In this paper, experiments with an air-breathing proton exchange membrane fuel cell (PEMFC) for mobile devices were carried out according to cathode conditions. These conditions are defined by the cathode flow field plate type (the channel type, the open type) and the cathode surface direction. Single-cell and 6-cell stack were used in the experiments. The experimental results showed that the open-type cathode flow field plate gave a better performance than the small channel type. In the experiments related to the direction of the slits on the cathode flow field plate, the horizontal slit cell was better than the vertical one. With respect to the cathode surface direction, when the cathode surface is placed in the direction normal to the ground, the PEMFC generated more stable power in the mass transport loss region. Since stable power in the mass transport region is closely related to the air supply, computational fluid dynamics (CFD) analysis for air-breathing PEMFC of different cathode surface directions was performed.

전류밀도에 따른 바나듐 레독스 흐름 전지의 효율 변화 (Change of the Efficiency in All-Vanadium Redox Flow Battery with Current Density)

  • 최호상;인대민;송영준;유철휘;황갑진
    • 한국수소및신에너지학회논문집
    • /
    • 제28권5호
    • /
    • pp.531-535
    • /
    • 2017
  • The performance of all-vanadium redox flow battery (VRFB) was tested with an increase of the current density. APS membrane (anion exchange membrane) and GF050CH (cabon felt) were used as a separator and electrode, respectively. An average energy efficiency of the VRFB was 79.5%, 68.1%, and 62.8% for the current density of $60mA/cm^2$, $120mA/cm^2$, and $160mA/cm^2$, respectively. It was confirmed that VRFB can be used as a energy storage system at the higher current density even if the energy efficiency was deceased about 21%.

On/Off 제어에 의한 습도와 결로의 제어에 관한 연구 (A Study on The Control of Humidification and Dew Condensation by On/Off Control)

  • 박대흠;김두희;김경훈;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.835-841
    • /
    • 2011
  • The humidification is essential for performance enhancement of the electrolysis of PEMFC because proton conductivity depends on hydration of the proton exchange membrane. In this study, the humidification experiment did about On/Off control the humidification and dew condensation for PEMFC by using of the membrane humidifiers. As the results, it was possible to approximation control of the humidity by using of the solenoid valve On/Off control on the membrane humidifier. Also the problem on the dew condensation was resolved by approximation humidity control through solenoid valve On/Off control and the removal of the dew condensation in the flow channel was verified through visualization experiment.