• Title/Summary/Keyword: Hydrogen ambient

Search Result 165, Processing Time 0.036 seconds

Influence of the cathode catalyst layer thickness on the behaviour of an air breathing PEM fuel cell

  • Ferreira-Aparicio, Paloma;Chaparro, Antonio M.
    • Advances in Energy Research
    • /
    • v.2 no.2
    • /
    • pp.73-84
    • /
    • 2014
  • Fuel cells of proton exchange membrane type (PEMFC) working with hydrogen in the anode and ambient air in the cathode ('air breathing') have been prepared and characterized. The cells have been studied with variable thickness of the cathode catalyst layer ($L_{CL}$), maintaining constant the platinum and ionomer loads. Polarization curves and electrochemical active area measurements have been carried out. The polarization curves are analyzed in terms of a model for a flooded passive air breathing cathode. The analysis shows that $L_{CL}$ affects to electrochemical kinetics and mass transport processes inside the electrode, as reflected by two parameters of the polarization curves: the Tafel slope and the internal resistance. The observed decrease in Tafel slope with decreasing $L_{CL}$ shows improvements in the oxygen reduction kinetics which we attribute to changes in the catalyst layer structure. A decrease in the internal resistance with $L_{CL}$ is attributed to lower protonic resistance of thinner catalyst layers, although the observed decrease is lower than expected probably because the electronic conduction starts to be hindered by more hydrophilic character and thicker ionomer film.

Characteristics of Distribution and Concentrations of Hydrogen Peroxide in Seoul Metropolitan Area (서울 도심 $H_2O_2$농도와 분포특성)

  • 강충민;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.31-38
    • /
    • 2001
  • Ambient ge-phase $H_2O$$_2$(Hydrogen Peroxide) concentrations were measured at four sites in downtown Seoul Korea. These measurements were mad during winter and summer, February 14~19 and 12~17, 1997. $H_2O$$_2$concentrations were quantified by fluorescence using enzyms. $H_2O$$_2$ concentrations in winter were below the limit of detection and was much higher concentrations in summer. The mean of all observations was 264 ppt and the range measured was 23ppt~1856ppt. The results from the correlation analysis showed that the concentration of gasous $H_2O$$_2$is dependent on the other air pollutants(O$_3$, NO$_2$) and meteorological parameter(solar radiation).

  • PDF

Development of Air Supply System for Fuel Cell Electric Bus (연료전지 버스용 공기공급시스템 개발)

  • Kim, Woo-June;Park, Chang-Ho;Cho, Kyung-Seok;Oh, Chang-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.561-564
    • /
    • 2007
  • FCEV uses electric energy which generated from the reaction between Hydrogen and Oxygen in fuel cell stack as driving force. As fossil fuels are exhausted, fuel cell is regarded as a potent substitute for next generation energy source, and thus, most of car-makers make every efforts to develop fuel cell electric vehicle (FCEV). In addition, fuel cell is also beneficial in aspect of environment, because only clean water is produced during chemical reaction process instead of harmful exhausted gas. Generally, Hydrogen is supplied from high-pressured fuel tank, and air blower (or compressor) supply Oxygen by pressurizing ambient air. Air blower which is driven by high speed motor consumes about $7{\sim}8$ % of energy generated from fuel cell stack. Therefore, the efficiency of an air blower is directly linked with the performance of FCEV. This study will present the development process of an air blower and its consisting parts respectively.

  • PDF

Development of Air Supply System for FCEV Bus (연료전지 버스용 공기공급시스템 개발)

  • Park, Chang-Ho;Cho, Kyung-Seok;Kim, Woo-June;Oh, Chang-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.417-420
    • /
    • 2006
  • FCEV uses electric energy generated from the reaction between Hydrogen and Oxygen in fuel cell stack as driving force. As fossil fuels are exhausted, fuel cell is regarded as a potent substitute for next generation energy source, and thus, most of car-makers make every efforts to develop fuel cell electric vehicle (FCEV). In addition, fuel cell is also beneficial in aspect of environment, because only clean water is produced during chemical reaction process instead of harmful exhausted gas. Generally, Hydrogen is supplied from high-pressured fuel tank, and air blower (or compressor) supplies Oxygen by pressurizing ambient air. Air blower which is driven by high speed motor consumes about $7{\sim}8%$ of energy generated from fuel cell stack. Therefore, the efficiency of an air blower is directly linked with the overall performance of FCEV. This study will present developing process of an air blower and its consisting parts respectively.

  • PDF

Hydrogen Peroxide Concentrations in Air in Seoul (서울시 대기 중 $H_2O_2$의 농도)

  • 강충민;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF

Characterization of Aqueous Solution Pretreatment for Serpentine Used Carbondioxide Sequestration Material (이산화탄소 포획 원료용 사문석의 수용액 전처리 평가)

  • Choi, Weon-Kyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.340-347
    • /
    • 2008
  • Dissolution process of serpentine in distilled water was systematically investigated for study on pre-treatment of serpentine which was a candidate material for carbon dioxide sequestration. The metallic ions(Ca, Si, Mg etc.) were dissolved in distilled water at ambient condition and their concentrations were changed with dissolution time. The precise evaluation of dissolution process for serpentine dissolved solvent was performed by ion conductivity and pH measurement. Serpentine dissolution in distilled water was evaluated as a stable pre-treatment process without changes of crystallographic structure and chemical structure changes.

Thermal Performance Analysis of Reciprocating Compressors for Refrigerator-freezers (냉장고용 왕복동 압축기의 성능 해석)

  • KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.236-243
    • /
    • 2016
  • This paper presents a simple thermo-physical model of reciprocating compressors for household refrigerator-freezers. The compressor model has been developed based on thermodynamic principles and large data sets from the compressor calorimeter tests. The input data are compressor geometry (displacement and clearance volume), compressor speed, suction pressure and temperature, discharge pressure, and ambient temperature. The model can estimate mass flow rate and compressor power consumption within 3.0% accuracy, which is not much larger than measurement errors associated with calorimeter testing under ideal conditions.

Estimation of the Concentration of HF in the Atmosphere Using Plant Leaves Exposed to HF in the Site of the HF Spill (불산 누출 사고 시 불산에 노출된 식물잎을 이용한 대기 중 불화수소 농도 추정)

  • Yim, Bongbeen;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.248-255
    • /
    • 2016
  • The leaves of three plant species, such as soybean, raspberry, and kudzu, exposed to hydrogen fluoride was collected in an area surrounding an emission source where the release accident occurred. The ultrasonic-assisted extraction and analysis of fluoride by ion chromatography was carried out. The mean concentration of fluoride in the leaves of three plant species exposed to hydrogen fluoride was $5,409{\pm}1,198mg\;F/kg\;dry\;wt$ and $788{\pm}339mg\;F/kg\;dry\;wt$, respectively. The mean fluoride concentration in ambient air were estimated to be $2.36{\pm}0.65mg/m^3$ ($2.89{\pm}0.79ppm$) and $0.35{\pm}0.15mg/m^3$ ($0.43{\pm}0.19ppm$) in exposed and unexposed sites, respectively. It seems likely that the passive monitoring using plant leaves could identify with respect to plant risk by fluoride in atmosphere.

Prediction of Malodorous Landfill Substances Effect on Ambient Air Quality - A Case Study on Cheongju·Cheongwon Metropolitan Landfill - (매립지 악취가 주변 대기질에 미치는 영향 예측 - 청주청원 광역매립지 사례연구 -)

  • Lee, Sang-Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.695-705
    • /
    • 2012
  • The purpose of this study is to investigate concentration level and characteristics of malodour substances generated from landfill site in C city. Also, it is tried to predict distribution of concentration level using ISCST3 model around landfill site. From the results, it can be confirmed that twelfth-class malodour substances such as ammonia, methyl mercaptan, hydrogen sulfide, dimethyl sulfate, dimethyl disulfate, toluene, acetaldehyde, styrene, propionaldehyde, butylaldehyde, n-Valeraldehyde, xylene were generated from landfill site. The levels of the malodour substances were lower than that of permeable concentration regulated by odor control law in Korea. However, the concentration of malodour substances including methyl mercaptan, hydrogen sulfide, acetaldehyde, and propionaldehyde exceeded threshold limit value(TLV). It was seemed that these substances caused the problem of offensive odor around circumstance of landfill. The concentration of malodour substances was higher in slant than in upper part of landfill. The concentrations of malodour substances measured at night time were shown higher level than those at night time because atmospheric condition was stable at night time. It showed that the concentration of malodour substances were higher in spring. The results of atmospheric diffusion model predicted that tolerance limit level of hydrogen sulfide and methyl mercaptan was detected within nearly 5km from the boundary of landfill.

A Study on Hydrogen Detection Characteristics of the Pt-MIS Capacitor Device (Pt-MIS 커패시터 소자의 수소가스 검지특성 연구)

  • Sung, Yung-Kwon;Yi, Seung-Hwan;Koh, Jung-Hyuk;Rhie, Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.69-75
    • /
    • 1999
  • The characteristics of $H_2$ gas detection have been investigated using the Pt-MIS capacitor composed of the LPCVD nitride on the oxide. The flat band voltage shift is measured as 0.1 V in 1,000 ppm $H_2$ gas ambient and to be independent of Pt catalyst thickness. It is found that the flatband voltage shift is proportional to the hydrogen concentrations. The response and recovery time of Pt-MIS capacitor are 5 mins and 25 mins respectively. The samples of 30nm thick Pt revealed much higher sensitivity than that of 150nm samples. The samples of 150nm Pt showed that the flatband voltage shift of the device is due to the formation of the dipole layer of the adsorbed hydrogen atoms at the Pt-insulator interface.

  • PDF