• 제목/요약/키워드: Hydrogel Ophthalmic Lens

검색결과 63건 처리시간 0.022초

Fabrication Technique of Nanoemulsion Using Silicone Oil and Application as Hydrophilic Ophthalmic Lens

  • Hye-In Park;A-Young Sung
    • 한국재료학회지
    • /
    • 제34권7호
    • /
    • pp.315-320
    • /
    • 2024
  • In order to maximize the function and increase the compatibility of silicone hydrogel lens, this study compared and analyzed the properties of Amino modified silicone oil using mini and microemulsion technique, respectively. Optical and physical properties were evaluated by spectral transmittance, refractive index, water content, oxygen transmittance and contact angle measurements to evaluate the performance of the manufactured hydrogel lens. The spectral transmittance results revealed the copolymerization method lens showed 31 % of the visible light area, which did not satisfy the basic optical properties. However, the lens using the mini and microemulsion materials showed more than 90 % of the visible light area, satisfying the optical characteristics. In addition, all physical properties were superior to a basic hydrogel lens. The mini and microemulsion techniques effectively improved the stability and function of the ophthalmic hydrogel lens and are considered a promising ways of manufacturing an ophthalmic hydrogel contact lens with increased compatibility and stability.

High Performance Materials for Ophthalmic Hydrogel Lens Containing Nanoparticles

  • Kim, Duck-Hyun;Sung, A-Young
    • 통합자연과학논문집
    • /
    • 제9권1호
    • /
    • pp.16-22
    • /
    • 2016
  • The optical and physical and characteristics of hydrogel ophthalmic lens polymerized with addition of 2,6-difluoropyridine, SiPc(silicon 2,9,16,23-tetra-tert-butyl-29H31H-phthalocyanine dihydroxide) and nanodiamond in the basic hydrogel material were evaluated. In particular, the utility of 2,6-difluoropyridine, SiPc and nanodiamond as a hydrogel ophthalmic lens material was investigated. 2,6-difluoropyridine, SiPc and nanodiamond were used as additives. And also, 2-hydroxyethyl methacrylate, acrylic acid, methyl methacrylate and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. The refractive index of 1.4348~1.4361, water content of 33.30~34.02%, UV-B transmittance of 4.77~67.50%, UV-A transmittance of 1.45~89.19% and visible transmittance of 32.12~92.21% were obtained. The results of hydrogel lens containing 2,6-difluoropyridine (add 5%) showed antibiosis for staphylococcus aureus. The produced copolymer is suitable for hydrogel soft ophthalmic lenses with antibiotic and anti-UV effect.

Preparation and Characterization of Ophthalmic Hydrophilic Silicone Lens Containing Zinc Oxide and Iron Oxide Nanoparticles

  • Shin, Su-Mi;Sung, A-Young
    • 한국재료학회지
    • /
    • 제31권8호
    • /
    • pp.427-432
    • /
    • 2021
  • This study uses silicone monomer, DMA, crosslinking agent EGDMA, and initiator AIBN as a basic combination to prepare hydrogel lenses using fluorine-based perfluoro polyether and iron oxide and zinc oxide nanoparticles as additives. After manufacturing the lens using iron oxide nanoparticles and zinc oxide nanoparticles, the optical, physical properties, and polymerization stability are evaluated to investigate the possibility of application as a functional hydrogel lens material. As a result of this experiment, it is found that the addition of the wetting material containing fluorine changes the surface energy of the produced hydrogel lens, thereby improving the wettability. Also, the addition of iron oxide and zinc oxide nanoparticles satisfies the basic hydrogel ophthalmic lens properties and slightly increases the UV blocking performance; it also increases the tensile strength by improving the durability of the hydrogel lens. The polymerization stability of the nanoparticles evaluated through the eluate test is found to be excellent. Therefore, it is judged that these materials can be used in various conditions as high functional hydrogel lens material.

Preparation and Performance Analysis of Ophthalmic Polymer Using SWCNT and SWCCNT

  • Shin, Su-Mi;Sung, A-Young
    • 한국재료학회지
    • /
    • 제29권12호
    • /
    • pp.735-740
    • /
    • 2019
  • The purpose of this study is to fabricate an ophthalmic lens by copolymerizing two types of carbon nanotubes and hydrophilic hydrogel lens materials, and to investigate its application as an ophthalmic lens material by analyzing its physical properties and antimicrobial effect. For polymerization, HEMA (2-hydroxyethyl methacrylate), EGDMA (ethylene glycol dimethacrylate), a crosslinking agent, and AIBN (azobisisobutyronitrile), an initiator, are used as a basic combination, and a single-walled carbon nanotube and a single-walled, carboxylic-acid-functionalized carbon nanotube are used as additives. To analyze the physical properties, the water content, refractive index, breaking strength, and antimicrobial effect of the fabricated lenses are measured. The fabricated lenses satisfies all the basic properties of the basic hydrogel ophthalmic lens. The water content increases with increasing amount of additive and decreases with addition of 0.2 % ratio of nanoparticles. The refractive index is inversely proportional to the water content result. As a result of the antimicrobial test of the fabricated lens, the addition of carbon nanotubes shows an excellent antimicrobial effect. Therefore, it is considered that the fabricated lens can be applied as a functional material for basic ophthalmic hydrogel lenses.

Protein Absorption and Characterization of Hydrogel Polymer Containing 2-Methacryloyloxyethyl Phosphorylcholine as Additive

  • Kim, Duck-Hyun;Sung, A-Young
    • 통합자연과학논문집
    • /
    • 제9권4호
    • /
    • pp.249-254
    • /
    • 2016
  • This study evaluated the physical and optical characteristics of hydrophilic ophthalmic polymer with addition of 2-methacryloyloxyethyl phosphorylcholine in the basic hydrogel ophthalmic lens material, and in particular, the utility of 2-methacryloyloxyethyl phosphorylcholine as an ophthalmic contact lens material for ophthalmologic devices was investigated. In this study 2-methacryloyloxyethyl phosphorylcholine were used as additives. For the preparation of hydrogel lens 2-hydroxyethyl methacrylate, methyl methacrylate, acrylic acid and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. The physical properties of the produced polymers were measured as followings. The refractive index of 1.433~1.393, water content of 35.95~53.16%, contact angle of $70.6{\sim}51.24^{\circ}$, UVB transmittance of 81.2~82.4%, UV-B transmittance of 81.2~82.4% and visible transmittance of 91.4~92.2% were obtained. Also, in case of protein absorption, the measurement showed that absorbance of Reference and MPC-10 sample was 0.2598 and 0.2250 respectively. Based on the results of this study, ophthalmic lens material containing 2-methacryloyloxyethyl phosphorylcholine is expected to be used usefully as a material for high wettability and inhibitor of protein adsorption for ophthalmic hydrogel lens.

산소투과성이 뛰어난 Hydrogel 콘택트렌즈 합성 (Polymerization of Hydrogel Contact Lens with High Oxygen Transmissibility)

  • 성아영;김태훈;공정일
    • 한국안광학회지
    • /
    • 제11권1호
    • /
    • pp.49-53
    • /
    • 2006
  • Diisocynate를 HEMA(2-hydroxyethylmethacrylate)와 DBTDL(Dibutylitin dilaurate) 촉매 하에서 반응시킨 후 다시 고 산소 투과성 특성을 가지는 bis(hydroxyalkyl)terminated poly(dimethylsiloxane)를 반응시켜 Acrylate-PDMS(Polydimethylsiloxane)-Urethane Prepolymer를 합성하였다. HEMA(2-hydroxyethyl-methacrylate)는 중합 가능한 prepolymer를 만들기 위해서 사용하였으며, Urethane의 도입은 탄성이 좋고 산소투과성을 높이기 위해 사용하였다. 이들의 반응은 FT-IR로 확인하였으며, 이 고분자 재료는 고 산소투과성 하이드로 젤 렌즈의 원료로 사용될 것이다.

  • PDF

Polymerization and Preparation of Functional Ophthalmic Material Containing Carbon Nanoparticles

  • Lee, Min-Jae;Sung, A-Young
    • 한국재료학회지
    • /
    • 제28권8호
    • /
    • pp.452-458
    • /
    • 2018
  • This research is conducted to create a functional hydrogel ophthalmic lens containing nanoparticles. Carbon nanoparticles and PEGMEMA are used as additives for the basic combination of HEMA, MA, and MMA, and the materials are copolymerized with EGDMA as the cross-linking agent and AIBN as the thermal initiator. The hydrogel lens is produced using a cast-mold method, and the materials are thermally polymerized at $100^{\circ}C$ for an hour. The polymerized lens sample is hydrated in a 0.9 % saline solution for 24 hours before the optical and physical characteristics of the lens are measured. The refractive index, water content, contact angle, light transmittance, and tensile strength are measured to evaluate the physical and optical characteristics of the hydrogel lens. The refractive index, water content, contact angle, UV-B light transmittance, UV-A light transmittance, visible light transmittance, tensile strength and breaking strength of the hydrogel lens polymer are 1.4019~1.4281, 43.05~51.18 %, $31.95{\sim}68.61^{\circ}$, 21.69~58.11 %, 35.59~84.26 %, 45.85~88.06 %, 0.1075~0.1649 kgf and 0.1520~0.2250 kgf, respectively. The results demonstrate an increase in refractive index, tensile strength and breaking strength and a decrease in contact angle and light transmittance. Furthermore, the visible light transmissibility is significantly increased at PEG 10 %. It is clear that this material can be used for high-performance ophthalmic lenses with wettability, ultraviolet ray blocking effect, and tensile strength.

Preparation and Physical Properties of Silicone Hydrogel Ophthalmic Lens Containing Hydrophilic Monomer

  • Lee, Min-Jae;Sung, A-Young
    • 대한화학회지
    • /
    • 제60권4호
    • /
    • pp.261-266
    • /
    • 2016
  • The major physical characteristics of macromolecules used in silicone hydrogel ophthalmic lenses include optical transmittance, oxygen permeability, water content, and refractive index. For the preparation of highly functional silicone hydrogel lens materials, two silicone monomers were used in the presence of 2-hydroxyethyl methacrylate (HEMA) and hydroxypropyl methacrylate (HPMA). The samples containing HEMA and HPMA had oxygen transmissibility (Dk) values in the range of 73.38–50.98 × 10-11 (cm2/s) (mLO2/mL×mmHg) and 71.94–42.80 × 10-11 (cm2/s) (mLO2/mL×mmHg), respectively. Furthermore, the water contents of samples containing HEMA and HPMA were in the range of 32.73–34.67% and 31.94–33.74%, respectively, and the refractive indices were in the range of 1.4348–1.4364 and 1.4385–1.4407, respectively. Thus, silicone monomers containing HEMA and HPMA are expected to be useful for fabricating high-oxygen-permeability silicon hydrogel ophthalmic lenses.

Physical Properties of Ophthalmic Hydrogel Polymer Containing Zinc Oxide Nanoparticles

  • Sung, A-Young;Kim, Tae-Hun
    • 통합자연과학논문집
    • /
    • 제6권2호
    • /
    • pp.76-81
    • /
    • 2013
  • ZnO nanoparticles and vinyl pyridine were added to the mixture of MMA (methyl methacrylate), HEMA (2-hydroxy ethyl methacrylate) and NVP (N-vinylpyrrolidone) in a mould at various concentrations. Cross-linker EGDMA (ethyleneglycoldimethacrylate) and AIBN (azobisisobutyronitrile) initiator were finally added to the mixture and then heated at $80^{\circ}C$ for 60 min to prepare high-performance hydrogel ophthalmic lens. The physical properties of the hydrogel ophthalmic material were investigated by measuring the average value of refractive index, water content and optical transmittance. The refractive index of 1.429~1.450, water content of 34~41%, and visible transmittance of 78~90% were obtained. The material is possibly used to manufacture UV-block hydrogel contact lens.

하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향 (Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness)

  • 서정익
    • 한국임상보건과학회지
    • /
    • 제5권4호
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.