• Title/Summary/Keyword: Hydrochloric acid

Search Result 632, Processing Time 0.025 seconds

Hydrochloric Acid Leaching of Arsenic from Arsenic-Bearing Copper Slime. (동전련 부산물인 함비소 동슬라임으로부터 염산에 의한 비소의 침출)

  • 유용주;황필규
    • Resources Recycling
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1992
  • The hydrochloric acid leaching has been studied as a fundamental experiment on the recovery of arsenic from arsenic-bearing copper slime in copper electrorefining. The slime is mainly composed of $\beta-Cu_3As$ Which is intermetallic compound of CU and As. And the minor components are $CU_2O$ and CusAs in the slime. The optimum conditions of leaching of the slime were found to be as follows : 6N hydrochloric acid, particle size passed through 140 mesh, leaching for 150 min at $60^{\circ}C$, ratio of HCI/slime of 3 to 1 ; where 98 percent of arsenic were leached out of the As-bearing slime.

  • PDF

Study on the Elution Behaviors of Molybdate and Tungstate in Both Hydrochloric and Perchloric Acid by Anion Exchange Chromatograpphy

  • Cha, Ki-Won;Choi, Jae-Sung;Park, Kee-Chae
    • Bulletin of the Korean Chemical Society
    • /
    • v.2 no.2
    • /
    • pp.37-41
    • /
    • 1981
  • The elution behaviors of molybdate and tungstate through anion exchange column have been investigated in the various concentration of hydrochloric and perchloric acid. A discussion is made to evaluate the existing these equilibrium and constant according to acidity. In both acids of 0.01-2.0 M concentration range, the existing equilibrium for molybdate and its constant calculated at $20^{\circ}C$ is $10^{18.9}$ for $Mo_8O_2^{4-} + 20H^+ {\rightleftharpoons} 8MoO_2^{2+} + 10H_2O$. In the 3-3.5 M hydrochloric acid it is 0.16 for $MoO_2Cl_2 + Cl^- {\rightleftharpoons} MoO_2Cl^{3-}$ and for the case of tungstate, in the both acids of 0.01-1.0 M concentration range $10^{6.6}$ for $W_{12}O_{39}^{6-} + 6H^+ {\rightleftharpoons} 12WO_3{\cdot}3H_2O$. In higher concentration than 1.0 M both acids the following equilibrium seems to be existed. $12WO_3{\cdot}3H_2O {\rightleftharpoons} 12WO_3 + 3H_2O$

The Synergistic Effect of 2-Chloromethylbenzimidazole and Potassium Iodide on the Corrosion behavior of Mild Steel in Hydrochloric Acid Solution

  • Zhou, Liben;Cheng, Weizhong;Wang, Deng;Li, Zhaolei;Zhou, Haijun;Guo, Weijie
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.138-147
    • /
    • 2022
  • The synergistic effect of 2-chloromethylbenzimidazole (2-CBI) and potassium iodide (KI) for mild steel in 1 M hydrochloric acid solution was investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The results showed that, with the addition of 100 ppm potassium iodide, the inhibition efficiecy (IE) of 100 ppm 2-CBI in 1 M hydrochloric acid had been improved from 91.14% to 96.15%. And synergistic parameter of 100 ppm 2-CBI with different amounts of potassium iodide is always greater than 1. The adsorption of potassium iodide combining with 100 ppm 2-CBI obeys to the Langmuir adsorption isotherm. Thermodynamic adsorption parameters, including ∆G0ads, ∆Ha and ∆Sa of the adsorption of the combinned inhibitor, as well as the Ea of the mild steel corrosion in 1 M HCl with the combinned inhibitor, were calculated.

Preparation and Properties of Polyaniline Co-doped with Dodecyl benzenesulfonic Acid/Hydrochloric Acid and Its Blend with Wateborne-Polyurethane (Dodecylbenzene Sulfonic Acid/Hydrochloric Acid Co-doping System을 이용한 Polyaniline 합성 및 Polyaniline/Waterborne-Polyurethane 블렌드에 관한 연구)

  • Kwon, Ji-Yun;Lee, Young-Hee;Kim, Han-Do
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.36-39
    • /
    • 2003
  • Conducting polymers are finding increasing number of applications in various electronic devices such as chemical sensors, electrochromic display, light emitting diodes, etc. Polyaniline(PANI) ranks among highly prospective conduction polymers. PANI was first synthesis in 1862[1] and has been extensively studied as a conducting polymer since the 1980s[2]. The side range of electrical, electrochemical and optical properties coupled with good environmental stability makes PANI potentially attractive for application as an electronic material. (omitted)

  • PDF

A Comparative Study of Acidemia-induced Hyperkalemia and Hyperkalemia-induced Acidemia (산혈증 유발 고칼륨혈증과 고칼륨혈증 유발 산혈증의 비교 연구)

  • Yoon, Jun-Oh;Park, Choon-Ok;Hwang, Sang-Ik;Kim, Chong-Whan;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.123-129
    • /
    • 1990
  • A comparative study of acid-base balance has been made between acidemia-induced hyperkalemia and hyperkalemia-induced acidemia. A group of rabbits was infused 0.1 N hydrochloric acid solution and metabolic acidosis was induced. Another group was administered 20 mM potassium chloride solution and hyperkalemia was induced. The third group was infused 0.1 N hydrochloric acid and 20 mM potassium chloride solution, simultaneously. Acid-base data and plasma potassium ion concentration were monitored every thirty minutes in these three groups of rabbits. Following results were obtained: 1 ) Along with the infusion of hydrochloric acid, acute metabolic acidosis was induced in the rabbits. Plasma bicarbonate ion concentration decreased primarily in this group. As a respiratory compensation, there was a tendency of reduction of arterial $Pco_{2}$. The alteration of data became larger along with the amount of administration and the time elapsed. However, hyperkalemia was not so severe compared with the second group. 2) In potassium chloride infused group, plasma potassium ion concentration increased along with the time elapsed and the amount of infusion. And the alteration of acid-base data was parrallel to the level of potassium ion concentration, above all depression of pH was prominent. 3) Above data suggest that when acute metabolic acidosis was induced, exchange of intracellular potassium ion with extracellular hydrogen ion seems significant for the regulation of extracellular acid-base balance. And when hyperkalemia was induced with the infusion of potassium chloride solution, the exchange of intracellular hydrogen ion with extracellular potassium ion also seems significant for the regulation of extracellular potassium balance. 4) In the group of rabbits infused hydrochloric acid and potassium simultaneously, disturbances of acid-base balance and potassium balance were much more severe than two other groups. In these mixed disturbances, the process of compensatory mechanism might be inhibited and one disturbance might aggregate each other. 5) Through above data it has been postulated that in acid-base disturbance potassium balance can be sacrificed as a compensatory mechanism, and vice versa in disturbance of potassium balance. And our data also suggest that hydrogen ion and potassium ion are compensatory pair, one another.

  • PDF

Removal of Impurities from Metallurigical Grade Silicon by Acid Washing (금속급(金屬級) 실리콘에서 산세척(酸洗滌)에 의한 불순물(不純物)의 제거(除去))

  • Lee, Man-Seung;Kim, Dong-Ho
    • Resources Recycling
    • /
    • v.20 no.1
    • /
    • pp.61-68
    • /
    • 2011
  • Impurity removal from metallurgical grade silicon by acid washing at $50^{\circ}C$ was investigated by employing sulfuric, nitric acid and the mixture of hydrochloric and hydrofluoric acid. Acid washing treatment had no effect on the removal of boron and the concentration of this clement after treatment was rather increased. In our experimental range, the removal percentage of phosphorus was 60%. In the acid washing with sulfuric and nitric acid, the removal percentage of major impurities was below 50%, which indicates that refining effect was not great with these acids. Acid washing with the mixture of hydrochloric and hydrofluoric acid led to removal percentage of higher than 90%. Data on the purity of silicon after acid washing at various conditions are reported.

Influence and Application of an External Variable Magnetic Field on the Aqueous HCl Solution Behavior: Experimental Study and Modelling Using the Taguchi Method (염산 수용액 거동에 대한 가변 외부 자기장의 적용과 영향: 실험 연구 및 Taguchi 법을 이용한 모델링)

  • Hashemizadeh, Abbas;Ameri, Mohammad Javad;Aminshahidy, Babak;Gholizadeh, Mostafa
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.215-224
    • /
    • 2018
  • Influences of the magnetic field on 5, 10 and 15 wt% (1.5, 3 and 4.5 M) HCl solution behaviour, which has widespread applications in petroleum well acidizing, were investigated in various conditions. Differences in the pH of magnetized hydrochloric acid compared to that of normal hydrochloric acid were measured. Taguchi design of experimental (DoE) method were used to model effects of the magnetic field intensity, concentration, velocity and temperature of acid in addition to the elapsed time. The experimental results showed that the magnetic field decreases [$H^+$] concentration of hydrochloric acid up to 42% after magnetization. Increasing the magnetic field intensity (with 28% contribution), concentration (with 42% contribution), and velocity of acid increases the effect of magnetic treatment. The results also demonstrated that the acid magnetization was-not influenced by the fluid velocity and heating. It was also displayed that the acid preserves its magnetic memory during time. The optimum combination of factors with respect to the highest change of [$H^+$] concentration was obtained as an acid concentration of 10% and an applied magnetic field of 4,300 Gauss. Due to the reduction of HCl reaction rate under the magnetization process, it can be proposed that the magnetized HCl is a cost effective and reliable alternative retarder in the matrix acidizing of hydrocarbon (crude oil and natural gas) wells.

Separation of Fission Products by Ion Exchange Method (이온 교환법(交換法)에 의한 핵분열생성물(核分裂生成物)의 분리(分離))

  • Lee, Byung-Hun;Bang, Je-Geon
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.1
    • /
    • pp.15-25
    • /
    • 1983
  • The sequential separation of Ru-103, Cs-137 and Ce-144 was carried out by organic cation exchanger, Amberite CG-120, and inorganic ion exchangers, silica gel and montmorillonite. The optimum conditions of Ru-103, Cs-137 and Ce-144 on Amberite CG-120 are 0.01M-, 0.01M- and 0.1IM- hydrochloric acid for the adsorption, and 3M-, 3M- and 5M-hydrochloric acid for the desorption, respectively. The optimum conditions of Ru-103, Cs-137 and Ce-144 on silica gel are pH 8, pH 8 and pH 8 for the adsorption. and 3M-, 1M- and 1M-hydrochloric acid for the desorption. respectively. The optimum conditions of Ru-103, Cs-137 and Ce-144 on montmorillonite are pH 8, 0.01M-hydrochloric acid and pH 4 for the adsorption, and 1M-, 5M- and 3M-hydrochloric acid for the desorption. respectively. The adsorption which occurs at lower ionic strength and the differences in desorption ionic strength are utilized for the separation of tracer mixture in continuous experiments. The individual separation of Ru-103, Cs-137 and Ce-144 can be carried out more efficiently with montmorillonite than with silica gel and Amberite CG-120.

  • PDF

Electrowinning of Tin from Acidic Chloride Effluents by Cyclone type Electrolytic Cell (염산용액에서 사이클론형 전해방식에 의한 주석의 전해채취)

  • Cho, Yeon-Chul;Kang, Myeong-Sik;So, Hong-Il;Lee, Joo-Eun;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2017
  • Cyclone electrowinning method was used to recover tin to metal in hydrochloric acid solution. The effects of flow rate, current density, tin concentration, and hydrochloric acid concentration on the electrowinning of tin were investigated. As the flow rate increased and the concentration of tin and hydrochloric acid decreased, the tin recovery and current efficiency increased. As the current density increased, the recovery rate increased but the current efficiency decreased. Tin can be effectively recovered at flow rates of 18 L/min., $3A/dm^2$, 2.5 g/L Sn, and 5 wt.% HCl.

A Study on th Quality Stabilization of Iron Oxide (산화철의 품질 안정화)

  • 변태봉;한기현;김형석;배우현
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.55-63
    • /
    • 1998
  • The main purpose of the present study is to reduce quality variation of iron oxide for soft ferrite produced at hydrochloric acid facility )HAF) in a cold rolled mill factory. We investigated the factor of iron oxide quality variation, the operating condition of hydrochloric acid facility and the iron oxide quality with the production lot. Based on this information, we liad developed proper working plan for the diminution of iron oxide quality variation. To reduce iron oxide quality variation, the first priority is to control the picking steels, which seriously affect iron oxide quality variation, and then to separate generated waste acid. theretore, it was possible to reduce iron oxide quality variation with the proper operation of various kinds of waste acid tanks. We could produce iron oxide below 20 ppm SiO$_{2}$ content variation by operation after separation waste acid generated at TCM line.

  • PDF