• Title/Summary/Keyword: Hydraulic Stability Analysis

Search Result 267, Processing Time 0.026 seconds

Reliability-based Design Method of Concrete Armour Units with Structural Stability (구조적 안정성을 고려한 콘크리트 피복재의 신뢰성 설계)

  • Lee Cheol-Eung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.3
    • /
    • pp.142-151
    • /
    • 2004
  • A method for the determination of concrete armor unit weights with hydraulic stability and structural stability may be formulated in this paper. The hydraulic stability is analyzed by using Hudson's formula, the structural stability is also studied by evaluation of maximum flexural tensile stresses in armor unit induced by the impact loads and by comparison of those with the tensile resistance strength directly. The applicable criteria for concrete armor units can be represented as a function of design wave heights with return period, armor weights, and tensile strengths for the practical uses. In addition, reliability analyses for two failure modes are carried out to take into account some uncertainties. Finally, a series system for two-failure mode analysis can be made up straightforwardly, by which the optimal weights of armor units can be estimated with the various relative breakages, given the specific target probability of failure under the concepts of reliability-based design method.

The Analysis of the Slope Stability in Embankment(I) (제체의 사면안정 해석(I))

  • 최기봉
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.134-142
    • /
    • 1997
  • The stability of an embankment Impounding a water reservoir is highly depend upon the location of seepage line with the embankment. To evaluate the accurate safety factor of an embankment, it is important to illustrate the seepage phenomenon. Of particular interest is the stability following a rapid change (drawdown) of reservoir level Seepage forces in embankments are easily determined if frictional forces are expressed in relation to hydraulic gradient Ⅰ. If a piezometer is inserted into a body of embankment, the level to which free water rises is a measure of the energy at that point. From model test result, it is possible to calculate safety factors of earth embankment. To assure the validity of this research, tests were conducted with numerical experimental models. And the experiment models were constructed with slopes of 1:1.0, 1:1.5, 1:2.0, 1:2.5. Analysis of experimental results, seepage force was analyzed according to downstream time, internal friction angle and cohesion, respectively.

  • PDF

Stability Analysis of Slope Considering Infiltration of Behind Ground (배면침투를 고려한 사면안정해석)

  • Shin, Jong-Ho;Kim, Hak-Moon;Jang, Kyung-Jun;Chae, Sung-Eun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1060-1067
    • /
    • 2009
  • Previous research on the slope failure has mainly reported that most of the slope failures occur due to surface rainfall infiltration in the rainy season. A slope of which surface is protected by shotcrete or plants, can also fail due to increase in pore water pressure from the ground water flow beneath the surface, rather than from the surface. In this study such case of slope behavior is investigated using the model test and numerical method including strength reduction method. Hydraulic boundary conditions of the slopes is considered using coupled numerical scheme. The failure mechanism of the slope is investigated and the effect of pore water pressure on slope safety is identified. Increase in pore water pressure due to lateral infiltration has significantly reduced the stability of slope.

  • PDF

A Prediction of Saturated Hydraulic Conductivity for Compacted Bentonite Buffer in a High-level Radioactive Waste Disposal System (고준위방사성폐기물 처분시스템의 압축 벤토나이트 완충재의 포화 수리전도도 추정)

  • Park, Seunghun;Yoon, Seok;Kwon, Sangki;Kim, Geon-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.133-141
    • /
    • 2020
  • A geological repository comprises a natural barrier and an engineered barrier system. Its design components consist of canisters, buffers, backfill, and near-field rock. Among the engineered barrier system components, bentonite buffers minimize the groundwater flow from near-field rock and prevent the release of nuclide. Investigation of the hydraulic conductivity of the buffer to groundwater flow is an important factor in the performance evaluation of the stability and integrity of the engineered barrier of the repository. In this study, saturated hydraulic conductivity tests were performed using Gyeongju bentonite at various dry densities and temperatures, and a hydraulic conductivity prediction model was developed through multiple regression analysis using the 120 result sets of hydraulic conductivity. The test results showed that the hydraulic conductivity tends to decrease as the dry density increases. In addition, the hydraulic conductivity increased with increasing temperature. The multiple regression analysis results showed that the coefficient of determination (R2) of the hydraulic conductivity prediction equation was as high as 0.93. The hydraulic conductivity prediction equation presented in this study could be used for the design of engineered barrier systems.

Estimation of Fluid-elastic Instability Characteristics on Group Plugged KSNP Steam Generator Tube (집단 관막음된 한국표준원전 증기발생기 전열관의 유체탄성불안정성 특성 평가)

  • 조봉호;유기완;박치용;박수기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.670-676
    • /
    • 2003
  • To investigate the group plugging effect the fluid-elastic instability analysis has been performed on various column and row number of the KSNP steam generator lutes. This study compares the stability ratio of the plugged tube with that of the intact one. The information on the thermal-hydraulic data of the steam generator have been obtained by using the ATHOS3-MOD1 code with and without the thermal energy transfer at the plugged region. Both of the boundary conditions of hot-leg temperature and feedwater mass flow rate are fixed for this investigation. From the results of this study the stability ratios inside the group plugging zone are decreased slightly. At the outside of group plugging zone, however, most of the stability ratios tend to be increased.

  • PDF

An Experimental Study on the Stability of Rubble Mound Structures by Wave Directionality (사석방파제의 안정성에 미치는 방향성효과에 관한 실험적 연구)

  • 손병규;류청로
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.2
    • /
    • pp.139-148
    • /
    • 2001
  • Phenomena induced by waves, such as overtopping, sediment transport, vibration/fluctuation and destruction of structures are highly influenced by the directionality of wave propagation. These phenomena are often dominated by non-linearity, and so hydraulic model experiments are widely adopted for stability analysis rather than numerical modeling, Thus, stability ofrubblc mound breakwaters(RMB) due to wavc directionality was experimentally investigated in this study. The incident wave angle $30^{\circ}$ was found more risky on the damage rate of RMB under directional regular waves, and the incident wave angle $40^{\circ}$ was found relatively risky under directional irregular waves. These results clarified the wave directionality effect on the stability ofRMB, These facts were found correspondent to the occurrence of the peak between $20^{\circ}$-$40^{\circ}$ with the directional frequency distribution of lIlO maximum water particle velocity.

  • PDF

A Study on the Dynamic Stability of a Power Pack for Heavy Construction Equipments (토목공사용 파워팩의 동적 안정성에 관한 연구)

  • Kim, Dong-Il;Kim, Chae-Sil;Lee, Sang-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.134-138
    • /
    • 2014
  • Power packs can change energy to hydraulic energy generated by an engine as a tool for use with civil engineering construction equipment. This paper determines which type of power pack meets the standards of construction machinery. A power pack was formulated as a three-dimensional model by using the software CATIA. A modal analysis was conducted using ANSYS Workbench, and the resonance was checked. Next, a harmonic analysis was conducted. The analytical results show that the dynamic stability of the power pack is assured.

The Study of the Design of a Hydraulic Torque Load Simulator Equipped with a Direct Drive Servo Valve and a Feed forward Compensator (직접 구동형 서보밸브와 전진 보상기를 적용한 유압식 토크 부하 시뮬레이터의 설계에 관한 연구)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.15 no.1
    • /
    • pp.16-27
    • /
    • 2018
  • Hydraulic torque load simulator is essential to test and qualify the performance of various angle control systems. Typically a flapper-type second stage servovalve is applied to the load simulator, but here the direct drive servovalve, which is a kind of one-stage valve and affected by the large flow force, is applied. Since the torque load is applied not to the stationary shaft but to the rotating shaft of the angle control system, the controlled torque of load simulator is not accurate due to the rotating speed of the angle control system. A feedforward compensator is designed and applied to minimize the disturbance-like effect. A mathematical model is derived and linearized to analyze the stability, accuracy and responsiveness of the torque load simulator. The parameter effects of a controller, servovalve, hydraulic motor, rotating spring shaft are analyzed and summarized. The goodness of the linear analysis is verified by the digital computer simulations using both the linear and nonlinear mathematical models.

A Hydraulic Conductivity Model Considering the Infiltration Characteristics Near Saturation in Unsaturated Slopes (불포화 사면의 포화 부근 침투 특성을 고려한 수리전도도 모델)

  • Oh, Se-Boong;Park, Ki-Hun;Kim, Jun-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.1
    • /
    • pp.37-47
    • /
    • 2014
  • Unsaturated hydraulic conductivity (HC) is integrated theoretically from soil water retention curves (SWRC) by Mualem capillary model, but the prediction of HC is extremely sensitive to small variation of matric suction near saturation. Near saturation, the Mualem HC based on smooth SWRC decreases abruptly and has problems in the reliability of hydraulic behavior and the stability of numerical solutions. To improve van Genuchten-Mualem (VGM) HC, the van Genuchten SWRC model is modified within range of low matric suction (arbitrary air entry pressure). At an arbitrary air entry pressure, the VG SWRC is linearized in log scale until full saturation. The modified VG SWRC does not affect the fit of actual retention behavior and either the parameters of original VG SWRC fit. Using the modified VG SWRC, the VGM HC is modified to integrate for each interval decomposed by arbitrary air entry pressure. An analytical solution on modified VGM HC is proposed each interval, to protect the rapid change in HC near saturation. For silty soils, VGM models of HC function underestimate the unsaturated permeability characteristics and especially show rapid reduction near saturation. The modified VGM model predicts more accurate HC functions for Korean weathered soils. Furthermore, near saturation, the saturated HC is conserved by the modified VGM model. After 2-D infiltration analysis of an actual slope, the hydraulic behaviors are compared for VGM and the modified models. The prediction by the proposed model conserved the convergence of solutions on various rainfall conditions. However, the solution by VGM model did not converge since the conductivity near saturation reduced abruptly for heavy rainfall condition. Using VGM model, the factor of safety is overestimated in both initial and final stage during heavy rainfall. Stability analysis based on infiltration analysis could simulate the actual slope failure by the proposed model on HC.

Analysis of Fluid-elastic Instability In the CE-type Steam Generator Tube (CE형 증기발생기 전열관에 대한 유체탄성 불안정성 해석)

  • 박치용;유기완
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.4
    • /
    • pp.261-271
    • /
    • 2002
  • The fluid-elastic instability analysis of the U-tube bundle inside the steam generator is very important not only for detailed design stage of the SG but also for the change of operating condition of the nuclear powerplant. However the calculation procedure for the fluid-elastic instability was so complicated that the consolidated computer program has not been developed until now. In this study, the numerical calculation procedure and the computer program to obtain the stability ratio were developed. The thermal-hydraulic data in the region of secondary side of steam generator was obtained from executing the ATHOS3 code. The distribution of the fluid density can be calculated by using the void fraction, enthalpy, and operating pressure. The effective mass distribution along the U-tube was required to calculate natural frequency and dynamic mode shape using the ANSYS ver. 5.6 code. Finally, stability ratios for selected tubes of the CE type steam generator were computed. We considered the YGN 3.4 nuclear powerplant as the model plant, and stability ratios were investigated at the flow exit region of the U-tube. From our results, stability ratios at the central and the outside region of the tube bundle are much higher than those of other region.