• 제목/요약/키워드: Hydraulic Pressure Test

검색결과 485건 처리시간 0.032초

극저온 터보펌프 성능시험설비의 개발 (Development of Cryogenic Turbopump Test Facility)

  • 강정식;김진선;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.340-345
    • /
    • 2003
  • Cryogenic turbopump test facility(CTTF) is designed and developed. Hydraulic and cavitation performance of turbopump in cryogenic environment can be measured. Working fluid is liquid nitrogen and operating temperature is $-197^{\circ}C$. Liquid nitrogen run tank, catch tank and pressurizing tank has been built and remote tank pressure control system are installed. Maximum power of turbopump is 320kW and its maximum speed is 32000rpm. Cryogenic fluids and lubricating systems are effectively separated that long test times are acquired. Therefore hydraulic and cavitation performance can be measured accurately and effectively. This facility will contribute greatly to the development of turbopump for KSLV.

  • PDF

지하 LPG 저장공동에서의 Clogging 추정을 위한 역해석 수치모형 (A Numerical Model of Inverse Analysis for Estimating the Clogging in the Underground LPG Storage Cavern)

  • 강태섭;한일영
    • 대한지하수환경학회지
    • /
    • 제4권3호
    • /
    • pp.161-167
    • /
    • 1997
  • 지하 LPG 저장공동의 모니터링 자료를 이용하여 투수계수를 추정하기 위한 Galerkin 유한요소역해석 수치모형(SK-EST)이 개발되었다. 이 역해석 수치모형은 해석영역 전체구간에 대해 수두(압)분포를 근사하여 구성된 행렬방정식을 계산함으로서 투수계수를 산출한다. 실제 적용성을 검증하기 위해 현재 운영중인 지하 LPG 저장공동 간극수압계의 모니터링 자료를 이용한 역해석을 실시하였다. 또한 간극수압계의 작동상태를 확인하기 위해 측정된 심도별 수압측정 자료를 이용하여 심도별 투수계수 변화를 개발된 수치모형(SK-EST)을 이용하여 추정하고 수압시험 결과와 비교하였다.

  • PDF

메인 엔진 탑-브레이싱의 효과적 배치에 관한 연구 (Study on Effective Arrangement of Main Engine Top-Bracing)

  • 정준모;민덕기
    • 대한조선학회논문집
    • /
    • 제48권4호
    • /
    • pp.289-298
    • /
    • 2011
  • This paper provides procedures to effectively determine arrangement of hydraulic type top-bracings, which are popular for the main engine of the mid and large sized commercial vessels. Analyzing the operation mechanism of hydraulic top-bracing, ideal unified nonlinear stiffness curve is presented for linear frequency response analysis and nonlinear transient response analysis. Nonlinear stiffnesses of the curve are determined based on the regression analysis of test results. It is noted from linear frequency response analysis, initial setting pressure is most important among the setting values of the other stiffness intervals. From transient response analyses for two top-bracing arrangement scenarios, it is recognized that, as far as initial setting pressure is well controlled for the concerning vessels, only two top-bracings are enough to suppress H-mode excitation forces from main engine.

연직배수재의 통수능력 저감요인 분석을 위한 실험적 연구 (Experimental Study on the Reduction of the Discharge Capacity of Vertical Drains)

  • 김찬기;채영수;이강일
    • 한국지반신소재학회논문집
    • /
    • 제4권3호
    • /
    • pp.3-10
    • /
    • 2005
  • 본 연구는 연직 배수재의 통수능력 저감 요인인 측방토압, 동수경사, 배수재의 변형에 의한 통수능력의 저감을 밝히기 위하여 현장조건에 가장 부합되는 고무 멤부레인 안에 하모니카형, 성곽형, 파이버형 드레인을 설치한 후 드레인 주변에 슬러리 상태의 점토를 넣고 통수능 특성에 관한 실험을 실시하였다. 그 결과 배수재의 종류에 따른 통수능력은 하모니카형, 성곽형, 파이버형 순으로 통수능력이 컸으며, 또한 측압 보다 동수경사에 대한 통수능력 감소가 높게 나타났다.

  • PDF

환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험 (Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor)

  • 이강희;김대호;전태현;김형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

Application of hydraulic cylinder testing to determine the geotechnical properties of earth-filled dams

  • Rodriguez, Roman F.;Nicieza, Celestino G.;Gayarre, Fernando L.;Lopez, Francisco L. Ramos
    • Geomechanics and Engineering
    • /
    • 제9권4호
    • /
    • pp.483-498
    • /
    • 2015
  • This article describes a new in-situ load test called the Hydraulic Cylinder Test (HCT) and its application to determine the geotechnical properties of soil-rock mixtures. The main advantages of the test are its easy implementation, speed of execution and low-cost. This article provides a detailed description of the equipment and the test procedure, and examines a case study of its application to determine the geotechnical properties of an earth-filled dam for a tailings pond. The containment dams of the ponds are made from blocks of gypsum and marl, obtained from the excavation of the ponds, mixed in a matrix of sands and clays. The size of the rocks varies between 1 and 30 cm. The HCT is particularly useful for determining the geotechnical properties of this type of soil-rock mixture. Nine HCTs were carried out to determine its strength (c, ${\phi}$) and deformation (B, G) properties. The results obtained were validated using the Bim strength criterion, recently proposed, and some pressure meter tests carried out beforehand. The properties obtained are used to analyze the stability of the dam using computer simulations and a modification to its design is proposed.

CHEMICAL COMPATIBILITY OF SOIL-BENTONITE CUT-OFF WALL FOR IN-SITU GEOENVIRONMENTAL CONTAINMENT

  • Inui, Toru;Takai, Atsushi;Katsumi, Takeshi;Kamon, Masashi;Araki, Susumu
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 3차
    • /
    • pp.135-139
    • /
    • 2010
  • A construction technique to install the soil-bentonite (SB) cut-off wall for in-situ geoenvironmental containment by employing the trench cutting and re-mixing deep wall method is first presented in this paper. The laboratory test results on the hydraulic barrier performance of SB in relation to the chemical compatibility are then discussed. Hydraulic conductivity tests using flexible-wall permeameters as well as swell tests were conducted for SB specimens exposed to various types and concentrations of chemicals (calcium chloride, heavy fuel oil, ethanol, and/or seawater) in the permeant and/or in the pore water of original soil. For the SB specimens in which the pore water of original soil did not contain such chemicals and thus the sufficient bentonite hydration occurred, k values were not significantly increased even when permeated with the relatively aggressive chemical solutions such as 1.0 mol/L $CaCl_2$ or 50%-concentration ethanol solution. In contrast, the SB specimens containing $CaCl_2$ in the pore water had the higher k values. The excellent linear correlation between log k and swelling pressure implies that the swelling pressure can be a good indicator for the hydraulic barrier performance of the SB.

  • PDF

Impact performance for high frequency hydraulic rock drill drifter with sleeve valve

  • Guo, Yong;Yang, Shu Yi;Liu, De Shun;Zhang, Long Yan;Chen, Jian Wen
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.39-46
    • /
    • 2016
  • A high frequency hydraulic rock drill drifter with sleeve valve is developed to use on arm of excavator. In order to ensure optimal working parameters of impact system for the new hydraulic rock drill drifter controlled by sleeve valve, the performance test system is built using the arm and the hydraulic source of excavator. The evaluation indexes are gained through measurement of working pressure, supply oil flow and stress wave. The relations of working parameters to impact system performance are analyzed. The result demonstrates that the maximum impact energy of the drill drifter is 98.34J with impact frequency of 71HZ. Optimal pressure of YZ45 rock drill is 12.8 MPa-13.6MPa, in which the energy efficiency reaches above 58.6%, and feature moment of energy distribution is more than 0.650.

모바일 유압장치에서 부하의 유지와 내림 특성 비교 (Analysis of Characteristics of Load Movement in Mobile Hydraulic Equipment)

  • 조미현;허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.17-22
    • /
    • 2018
  • Mobile hydraulics require higher energy efficiency, and a simpler as well as robust design, than general industrial hydraulics. The 6/3-way directional control valve is widely used as a mobile hydraulic control valve. However, since the 6/3-way directional control valve is a spool type valve, it is difficult to maintain the load. A counterbalance valve is typically used, to maintain the load, and lift down. However, in an industrial field using a mobile hydraulics device, a pilot controlled check valve may be used to implement holding and lifting operation of the self-weight load, and a relief valve may be used simply to exert back pressure. But no comparative analysis of advantages and disadvantages of each method was revealed. In this study, various methods of holding and unloading load with self-weight in mobile hydraulics are investigated, and compared through simulation using AMESim software. This is experimentally verified by using Festo's mobile hydraulic test rig TP800.

압력보상형 유압펌프 신뢰성 시험평가 기술 (Reliability Test Assessment Technique for Pressure Compensation Type Hydraulic Pump)

  • 정동수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권4호
    • /
    • pp.371-385
    • /
    • 2011
  • Because consumer mostly utilizes company test standard, supplier spends burden of expenses on building test equipments and managing expert manpower to fulfill consumer's various tests. Therefore, it is urgent to standardize test assessment which has a bond of sympathy between consumer and supplier and evaluates reliability of their products. This study develops reliability assessment standard which is composed of 12 test items considering international and domestic test standards, company internal test standards of consumer companies and field conditions. Also this study introduces overall technical procedure on accelerated test with no failure which is used for the main technology of reliability assessment. To verify effectiveness of reliability assessment, the test results are herein analyzed through building the test equipments and performing the test items.