• 제목/요약/키워드: Hydraulic Pressure Test

검색결과 483건 처리시간 0.025초

A Numerical Model of Inverse Analysis for Estimating the Clogging in the Underground LPG Storage Cavern (지하 LPG 저장공동에서의 Clogging 추정을 위한 역해석 수치모형)

  • 강태섭;한일영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • 제4권3호
    • /
    • pp.161-167
    • /
    • 1997
  • A numerical model (SK-EST) for estimating hydraulic conductivity using monitoring data of underground LPG storage cavern was developed. The model calculates hydraulic conductivity from matrix equation which is established from the distribution of hydraulic potential. To verify the applicability of this model, an inverse analysis was performed using the monitoring data of pressure cell of an operating underground LPG storage cavern. And also using the water pressure parker test data which were obtained to look over the operation capability of pressure cell, conductivity variation with depth was estimated using the developed numerical model (SK-EST) and was compared with in situ results.

  • PDF

Study on Effective Arrangement of Main Engine Top-Bracing (메인 엔진 탑-브레이싱의 효과적 배치에 관한 연구)

  • Choung, Joon-Mo;Min, Dug-Ki
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제48권4호
    • /
    • pp.289-298
    • /
    • 2011
  • This paper provides procedures to effectively determine arrangement of hydraulic type top-bracings, which are popular for the main engine of the mid and large sized commercial vessels. Analyzing the operation mechanism of hydraulic top-bracing, ideal unified nonlinear stiffness curve is presented for linear frequency response analysis and nonlinear transient response analysis. Nonlinear stiffnesses of the curve are determined based on the regression analysis of test results. It is noted from linear frequency response analysis, initial setting pressure is most important among the setting values of the other stiffness intervals. From transient response analyses for two top-bracing arrangement scenarios, it is recognized that, as far as initial setting pressure is well controlled for the concerning vessels, only two top-bracings are enough to suppress H-mode excitation forces from main engine.

Experimental Study on the Reduction of the Discharge Capacity of Vertical Drains (연직배수재의 통수능력 저감요인 분석을 위한 실험적 연구)

  • Kim, Chan-Kee;Chae, Young-Su;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • 제4권3호
    • /
    • pp.3-10
    • /
    • 2005
  • This paper aims at investigating the characteristics of discharge capacity according to lateral pressure, hydraulic gradient and deformation of drain materials. A series of experiments were conducted to achieve this objective. In experiments, fiver drain boards as well as harmonica and castle types of drain boards were installed in a rubber membrane, and clay in sully was filled around them. The test results showed that the harmonica type of drain boards have the greatest discharge capacity comparing to castle and fiber drain boards. The results also indicated that the hydraulic gradient has more effect on reduction of discharge capacity than the lateral pressure.

  • PDF

Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor (환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Chun, Tae-Hyun;Kim, Hyung-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

Application of hydraulic cylinder testing to determine the geotechnical properties of earth-filled dams

  • Rodriguez, Roman F.;Nicieza, Celestino G.;Gayarre, Fernando L.;Lopez, Francisco L. Ramos
    • Geomechanics and Engineering
    • /
    • 제9권4호
    • /
    • pp.483-498
    • /
    • 2015
  • This article describes a new in-situ load test called the Hydraulic Cylinder Test (HCT) and its application to determine the geotechnical properties of soil-rock mixtures. The main advantages of the test are its easy implementation, speed of execution and low-cost. This article provides a detailed description of the equipment and the test procedure, and examines a case study of its application to determine the geotechnical properties of an earth-filled dam for a tailings pond. The containment dams of the ponds are made from blocks of gypsum and marl, obtained from the excavation of the ponds, mixed in a matrix of sands and clays. The size of the rocks varies between 1 and 30 cm. The HCT is particularly useful for determining the geotechnical properties of this type of soil-rock mixture. Nine HCTs were carried out to determine its strength (c, ${\phi}$) and deformation (B, G) properties. The results obtained were validated using the Bim strength criterion, recently proposed, and some pressure meter tests carried out beforehand. The properties obtained are used to analyze the stability of the dam using computer simulations and a modification to its design is proposed.

CHEMICAL COMPATIBILITY OF SOIL-BENTONITE CUT-OFF WALL FOR IN-SITU GEOENVIRONMENTAL CONTAINMENT

  • Inui, Toru;Takai, Atsushi;Katsumi, Takeshi;Kamon, Masashi;Araki, Susumu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 3차
    • /
    • pp.135-139
    • /
    • 2010
  • A construction technique to install the soil-bentonite (SB) cut-off wall for in-situ geoenvironmental containment by employing the trench cutting and re-mixing deep wall method is first presented in this paper. The laboratory test results on the hydraulic barrier performance of SB in relation to the chemical compatibility are then discussed. Hydraulic conductivity tests using flexible-wall permeameters as well as swell tests were conducted for SB specimens exposed to various types and concentrations of chemicals (calcium chloride, heavy fuel oil, ethanol, and/or seawater) in the permeant and/or in the pore water of original soil. For the SB specimens in which the pore water of original soil did not contain such chemicals and thus the sufficient bentonite hydration occurred, k values were not significantly increased even when permeated with the relatively aggressive chemical solutions such as 1.0 mol/L $CaCl_2$ or 50%-concentration ethanol solution. In contrast, the SB specimens containing $CaCl_2$ in the pore water had the higher k values. The excellent linear correlation between log k and swelling pressure implies that the swelling pressure can be a good indicator for the hydraulic barrier performance of the SB.

  • PDF

Impact performance for high frequency hydraulic rock drill drifter with sleeve valve

  • Guo, Yong;Yang, Shu Yi;Liu, De Shun;Zhang, Long Yan;Chen, Jian Wen
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.39-46
    • /
    • 2016
  • A high frequency hydraulic rock drill drifter with sleeve valve is developed to use on arm of excavator. In order to ensure optimal working parameters of impact system for the new hydraulic rock drill drifter controlled by sleeve valve, the performance test system is built using the arm and the hydraulic source of excavator. The evaluation indexes are gained through measurement of working pressure, supply oil flow and stress wave. The relations of working parameters to impact system performance are analyzed. The result demonstrates that the maximum impact energy of the drill drifter is 98.34J with impact frequency of 71HZ. Optimal pressure of YZ45 rock drill is 12.8 MPa-13.6MPa, in which the energy efficiency reaches above 58.6%, and feature moment of energy distribution is more than 0.650.

Analysis of Characteristics of Load Movement in Mobile Hydraulic Equipment (모바일 유압장치에서 부하의 유지와 내림 특성 비교)

  • Jo, Mi Hyeon;Huh, Jun Young
    • Journal of Drive and Control
    • /
    • 제15권4호
    • /
    • pp.17-22
    • /
    • 2018
  • Mobile hydraulics require higher energy efficiency, and a simpler as well as robust design, than general industrial hydraulics. The 6/3-way directional control valve is widely used as a mobile hydraulic control valve. However, since the 6/3-way directional control valve is a spool type valve, it is difficult to maintain the load. A counterbalance valve is typically used, to maintain the load, and lift down. However, in an industrial field using a mobile hydraulics device, a pilot controlled check valve may be used to implement holding and lifting operation of the self-weight load, and a relief valve may be used simply to exert back pressure. But no comparative analysis of advantages and disadvantages of each method was revealed. In this study, various methods of holding and unloading load with self-weight in mobile hydraulics are investigated, and compared through simulation using AMESim software. This is experimentally verified by using Festo's mobile hydraulic test rig TP800.

Reliability Test Assessment Technique for Pressure Compensation Type Hydraulic Pump (압력보상형 유압펌프 신뢰성 시험평가 기술)

  • Jung, Dong-Soo
    • Journal of Applied Reliability
    • /
    • 제11권4호
    • /
    • pp.371-385
    • /
    • 2011
  • Because consumer mostly utilizes company test standard, supplier spends burden of expenses on building test equipments and managing expert manpower to fulfill consumer's various tests. Therefore, it is urgent to standardize test assessment which has a bond of sympathy between consumer and supplier and evaluates reliability of their products. This study develops reliability assessment standard which is composed of 12 test items considering international and domestic test standards, company internal test standards of consumer companies and field conditions. Also this study introduces overall technical procedure on accelerated test with no failure which is used for the main technology of reliability assessment. To verify effectiveness of reliability assessment, the test results are herein analyzed through building the test equipments and performing the test items.

The Hydraulic simulation and removal characteristics of Escherichia Coli for Ultraviolet rays.Ozone sterilization apparatus (자외선.오존 살균소독장치의 유체시뮬레이션 및 대장균 제거 특성)

  • Hwang, In-Ah;Lee, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.169-172
    • /
    • 2005
  • The simulation of Hydraulic pressure distribution of discharge tube with globular beads and the removal characteristic of Escherichia coli by the discharge tube with globular beads were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the passing amount of test water in discharge tube is increased, the removal ratio of Escherichia coli was increased because passing numbers of electric field section is increased.

  • PDF