• Title/Summary/Keyword: Hybrid device

Search Result 613, Processing Time 0.037 seconds

Digital Satellite Broadcasting Hybrid Service Trend (디지털 위성방송 Hybrid 서비스 동향)

  • Lee, Han
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.4
    • /
    • pp.193-197
    • /
    • 2008
  • In today's Pay TV market, the importance of TPS for Pay TV operators is increasing rapidly. IP Hybrid services are essential for satellite broadcasters. This paper explains the various digital satellite broadcasting service trend, especially IP based hybrid service approach of satellite broadcasters(BskyB, CanalSat, DirecTV, etc.). Also this paper introduces SkyLife IP hybrid business approach to achieve a strong leadership in Pay TV market and related IP convergence market in Korea.

  • PDF

A Study on Characteristics of Hybrid Damping Device Combining Rubber Core Pad and Hysteretic Steel Slit (고무코어패드와 강재이력감쇠장치를 결합한 복합감쇠장치의 이력특성에 관한 연구)

  • Park, Byung-Tae;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • This study proposes an RCS composite damping device that can achieve seismic reinforcement of existing buildings by dissipating energy by inelastic deformation. A series of experiments assessing the performances of the rubber core pad, hysteretic steel slit damping device, and hybrid RCS damping device were conducted. The results showed that the ratios of the deviations to the mean values satisfied the domestic damping-device conformity condition for the load at maximum device displacement in each direction, at the maximum force and minimum force at zero displacement, as well as the hysteresis curve area. In addition, three analysis models based on load-displacement characteristics were proposed for application to seismic reinforcement design. In addition, the validity of the three proposed models was confirmed, as they simulated the experimental results well. Meanwhile, as the shear deformation of the rubber-core pad increased, the hysteretic behavior of super-elasticity greatly increased the horizontal force of the damping device. Therefore, limiting the allowable displacement during design is deemed to be necessary.

A Study on Hybrid Control Unit Using a Smart Control (스마트 제어를 이용한 하이브리드 형 제어장치 연구)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1093-1100
    • /
    • 2016
  • This study is to demonstrate the superiority and stability of the solar - wind power hybrid power generation system for street lamps using super capacitor EDLC(:Electric Double Layer Capacitor). It is aiming to apply the lighting device using LED light source as the load of solar-wind power hybrid power generation system for independent power source and to develop the street light system device with high output power generation system. Unlike conventional controllers, EDLC, which is used as an auxiliary device for storing the developed power in the battery, can guarantee the high output and long life of the battery.

Electro-optic Characteristics of Hybrid Aligned Nematic Liquid Crystal Display Driven by Fringe Field (프린지 필드에 의해 구동되는 하이브리드형 네마틱 액정 디스플레이의 전기광학 특성)

  • 정연학;김향율;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.524-528
    • /
    • 2002
  • Conventional hybrid aligned nematic liquid crystal display (HAN-LCD) has several advantages on low operating voltage, fast response time and rubbing free on one substrate. We have fabricated a new hybrid aligned nematic display driven by fringe field. The new device exhibits much wider viewing: angle than that of the conventional HAN mode, owing to almost in-plane rotation of the LC director. Furthermore, we have developed the device that reveals more efficient electro-optic characteristics by placing common electrode on top and bottom substrates. In this paper, the electro-optic characteristics of the novel cell are investigated.

Seismic Performance Evaluation of Structures Retrofitted with Viscoelastic-Slit Hybrid Dampers (점탄성-슬릿 복합댐퍼로 보강된 건물의 내진성능평가)

  • Kim, Minsung;Xu, Zhaodong;Kim, Jinkoo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.361-367
    • /
    • 2018
  • This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.

A Study on the Development of the Dynamic Photoelastic Hybrid Method for Isotropic Material (등방성체용 동적 광탄성 하이브리드 법 개발에 관한 연구)

  • Sin, Dong-Cheol;Hwang, Jae-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2220-2227
    • /
    • 2000
  • In this paper, dynamic photoelastic hybrid method is developed and its validity is certified. The dynamic photoelastic hybrid method can be used on the obtaining of dynamic stress intensity factors and dynamic stress components. The effect of crack length on the dynamic stress intensity factors is less than those on the static stress intensity factors. When structures are under the dynamic mixed mode load, dynamic stress intensity factor of mode I is almost produced. Dynamic loading device manufactured in this research can be used on the research of dynamic behavior when mechanical resonance is produced and when crack is propagated with the constant velocity.

Narrow Viewing Angle Characteristics of a Fringe-Field Driven Hybrid Aligned Nematic Liquid Cystal Display (Fringe-Field 구동형 Hybrid Aligned Nematic 액정 디스플레이의 좁은 시야각 특성 연구)

  • Lee, Ji-Youn;Ryu, Jae-Woo;Lim, Young-Jin;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.440-441
    • /
    • 2006
  • We have studied the narrow viewing angle liquie crystal displays (LCDs) using a hybrid aligned nematic liquid crystal (LC) cell driven by a fringe field. The device using a LC with positive dielectric anisotropy has a relatively low transmittance. This paper describes how to improve light efficiency by optimizing electrode structure. The results show that the device exhibits a high transmittance of 90%, low driving voltage and narrow viewing angle less than $20^{\circ}$ along horizontal direction which is highly effective for private display application.

  • PDF

Experimental Evaluation for Structural Performance of Hybrid Damper Combining Steel Slit and Rotational Friction Damper (강재 슬릿과 회전 마찰형 감쇠 장치를 결합한 복합 감쇠 장치의 실험적 구조 성능 평가)

  • Kim, Yu-Seong;Kang, Joo-Won;Park, Byung-Tae;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.101-109
    • /
    • 2019
  • In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.