Abstract
This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.
Keywords
Energy dissipation device; Seismic retrofit; Optimum design; Fragility analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Marshall JD, Charney FA. Seismic response of steel frame structures with hybrid passive control systems. Earthquake Engineering & Structural Dynamics. 2012;41(4):715-733.   DOI
2 Zahrai SM, Moradi A, Moradi M. Using friction dampers in retrofitting a steel structure with masonry infill panels. Steel and Composite Structures. 2015;19(2):309-325.   DOI
3 Xu Z, Xu F, Chen X. Study on intelligent vibration isolation and mitigation of the platform by using MR and VE devices. Journal of Aerospace Engineering. ASCE. 2016;29(4):1-10.
4 Lee J, Kang H, Kim J. Seismic performance of steel plate slit-friction hybrid dampers. Journal of Constructional Steel Research. 2017;136:128-139.   DOI
5 Chan RWK, Albermani F. Experimental study of slit damper for passive energy dissipation. Engineering Structures. 2008;30(4):1058-1066.   DOI
6 Perform 3D. Computer and Structures. Inc. PERFORM User Guide ver 4. c2006.
7 ASCE/SEI 7-13. American Society of Civil Engineers. Minimum Design Loads for Buildings and Other Structures: Reston. c2013.
8 PEER. PEER NGA Database, Pacific Earthquake Engineering Research Center, University of California. Berkeley. USA. 2017. Available from: http://peer.berkeley.edu/nga.
9 Sivanandam SN, Deepa SN. Introduction to Genetic Algorithms. Berlin: Springer. c2008.
10 Cornell CA, Jalayer F, Hamburger RO, Foutch DA. The probabilistic basis for the 2000 SAC/FEMA steel moment frame guidelines. ASCE. Journal of Structural Engineering. 2002;128(4):526-533.   DOI
11 HAZUS-MH 2.1. Technical Manual. Federal Emergency Management Agency. Washington DC. USA. c2010.