• Title/Summary/Keyword: Human-Machine Interface(HMI)

Search Result 126, Processing Time 0.03 seconds

A Light-weight ANN-based Hand Motion Recognition Using a Wearable Sensor (웨어러블 센서를 활용한 경량 인공신경망 기반 손동작 인식기술)

  • Lee, Hyung Gyu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.4
    • /
    • pp.229-237
    • /
    • 2022
  • Motion recognition is very useful for implementing an intuitive HMI (Human-Machine Interface). In particular, hands are the body parts that can move most precisely with relatively small portion of energy. Thus hand motion has been used as an efficient communication interface with other persons or machines. In this paper, we design and implement a light-weight ANN (Artificial Neural Network)-based hand motion recognition using a state-of-the-art flex sensor. The proposed design consists of data collection from a wearable flex sensor, preprocessing filters, and a light-weight NN (Neural Network) classifier. For verifying the performance and functionality of the proposed design, we implement it on a low-end embedded device. Finally, our experiments and prototype implementation demonstrate that the accuracy of the proposed hand motion recognition achieves up to 98.7%.

A Study on Improvement of PSD Interface Using 2.4GHz Wireless Communication, (2.4GHz 무선 통신을 이용한 PSD 인터페이스 개선에 관한 연구)

  • Kim, Jae-Pil;Hyun, Yong-Sub;Chang, Kyong-Song
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1408-1415
    • /
    • 2007
  • To operate Platform Screen Door (PSD) automatically, the operational data of PSD and the train must be interfaced properly. PSD and train are operated together by the signaling system in Automatic Train Operation (ATO) signaling system zone where interfaces are provided between PSD and train. However, the additional PSD interface system with train is required in train operating zone without the interface between PSD and train. For the PSD interface, the wireless communication system or the train status (train correct stop status / train door status) detection system has been used. Seoul Metro line No.2. has the PSD wireless communication system using 447MHz band RF. For the safety of PSD operation, it is required to prevent RF interference in the subway environment where many frequencies exist. In this paper, the PSD wireless communication system is developed using 2.4GHz band RF to prevent the interference of the wireless communication and increase the traffic of the PSD interface. Furthermore, the improved system can store, manage and display the PSD and train operational data using Human Machine Interface (HMI) in the train's driver cab.

  • PDF

A Study on Gel-free Probe for Detecting EEG (뇌파 탐지용 Gel-free probe 연구)

  • Yun, Dae-Jhoong;Eum, Nyeon-Sik;Jeong, Myung-Yung
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.156-166
    • /
    • 2012
  • Over the past 15 years productive BCI research programs have arisen. Current mainstream EEG electrode setups permit efficient recordings but most of electrodes has the disadventages of need for skin preparation and gel application to correctly record signals. The new gel-free probe was adapted for EEG recording and it can be fixed to the scalp with the micro needle without neuro-gel. It use standard EEG cap for wearing electrodes on scalp so it is compatible with standard EEG electrodes. A comparison between electrode characteristics is achieved by performing simultaneous recordings with the gel electrodes and gel-free probe placed in parallel scalp positions on the same anatomical regions. The quality of EEG recordings for all two types of experimental conditions is similar for gel-electrodes and gel-free probe. Subjects also reported not having special tactile sensations associated with wearing of gel-free probes. According to our results, it is expected that gel-free probe can be adapted to BCI, BMI(Brain Machine Interface), HMI(Human Machine Interface) because of its simple application and comfortable wearing process.

A Fuel Cell Simulator for Control Logic Verification and Operator Training (제어로직 검증 및 운전원 훈련용 연료전지 시뮬레이터)

  • Maeng, Jwayoung;Kim, Sungho;Jung, Wonhee;Kang, Seungyup;Hong, Sukkyu;Lee, Sekyoung;Yook, Simkyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.75.1-75.1
    • /
    • 2010
  • This research presents a fuel cell simulator for control logic verification and operator training. Nowadays, power industries are focusing on clean energy as a response to new policy. The fuel cell can be the solution for clean energy, but operating technology is not well developed compared to other conventional power plans because of its short history. Therefore we need a simulator to verify the new control strategy and train operators, because the price of a real fuel cell system is too high and mechanically weak to be used for these kind of purposes. To develop the simulator, a 300 KW MCFC(Molten Carbonate Fuel Cell) system was modeled with stack, BOPs(pre-reformer, steam generator, etc) and mechanical components(valves, pipes, pumps, blowers, etc). The process model was integrated to emulated control system and HMI(Human Machine Interface). A static load and open loop tests were conducted for verifying the accuracy of the process model, since it is the most important part in the simulation. After verifying the process model, an automatic load change and start-up tests were conducted to verify the performance of a new control strategy(logic and functional loops).

  • PDF

Development of Sensor and Signal Duplicator for Building Automation (빌딩 자동제어용 센서 및 신호의 듀플리케이터(Duplicator) 개발)

  • Jang, Kyeong-Uk;Lee, Yong-Min;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.184-187
    • /
    • 2016
  • In this paper, we propose the sensor and the signal duplicator for the automatic building control. Developed duplicator realizes the sensor data collection apparatus and mimics the measured data and, thus, reduces the construction cost by using logical communication layer. Furthermore, the system supports the open protocols and can be associated with HMI(Human Machine Interface) used on the market. Developed duplicator is proved to be functional within the real environment. Measurement error rate, operating temperature, and operating humidity show very good results by the certified testing apparatus and organization.

Development of Intelligent Demand Controller (지능형 최대수요전력관리장치의 개발)

  • 김병진;정을기;한운동;전희종
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.50-55
    • /
    • 2000
  • In this paper, the intelligent demand control system was introduced. This system was composed of Intelligent demand controller, RTU(Remote Terminal Unit) and HMI(Human Machine Interface) program.The main features of developed system meter recommended by KEPCO. Secondly, the developed demand controller had a measurement function, so system could be simplified. Thirdly, network function was implemented to control a distanced loads. With program, the users who was not trained could operate system. Additionally, management based Web was considered to monitor and manage the system remotely. The system performance was proved in a several experiments.

  • PDF

A Study of Integrated SCADA System for Wind Farm to Support Interoperability (이기종간의 상호운용을 지원하는 풍력발전 통합 SCADA 시스템에 관한 연구)

  • Kim, Young-Gon;Moon, Chae-Joo;Joo, Yeong-Tae;Park, Tae-Sik;Chang, Young-Hak
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.70-76
    • /
    • 2013
  • Recently industrial control systems have been required to ensure intelligent, high tech automation, interconnection and interoperability demands. Therefore, there is a need to redefine the structure concepts of SCADA system for wind power. Also, at this time, the integrated management system is required for the distributed development of wind farms where are needed often interoperability features and exchange information between different wind farms, wind turbines or SCADA systems. In this paper, an integrated structural concepts for SCADA system are defined. Based on this definition of an integrated SCADA system, the basic designs are analyzed on physical layer, system layer and application layer which are corresponded to wind turbine controller, the SCADA server and the SCADA client, and implement HMI. Between the implementation SCADA server and the client, their normal functions were verified at the small scale wind energy test facilities.

Development of Lightning Arrester Degradation Monitoring System Using ZCT (ZCT틀 이용한 피뢰기 열화 감시 시스템 개발)

  • Park, J.N.;Lee, Y.H.;Jang, S.H.;Kim, P.S.;Shin, Y.S.;Kim, Y.G.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1626-1628
    • /
    • 2003
  • The lightning arrester is a very important overvoltage protection device in the electric power system. Therefore, the inspection of lightning arrester whether it keeps its performance or not properly has close related to verifying the safety confidence of the electric power system. But the development of the deterioration measuring method and on-line detecting system, is necessary to monitor the deterioration of the lightening arrestor. In this paper, we developed the lightning arrester degradation monitoring system. This system detected leakage current of lightning arrester by using the ZCT, and analyze the third harmonics ingredient of leakage current using DFT method in the Data Acquisition Unit(DAU). The analyzed current signal is transmit to the Human-Machine Interface(HMI), and HMI alarmed when accident are occurred and informed with the amplitude of leakage current to the operator.

  • PDF

Integrated Air Traffic Simulations of Manned and Remotely Piloted Aircraft (유무인항공기 통합 시뮬레이션 연구)

  • Oh, Hyeju;Park, Bae-Seon;Choi, Keeyoung;Lee, Hak-Tae;Jung, Hyun-Tae;Moon, Woo-Choon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.492-498
    • /
    • 2015
  • With the rapid growth of technologies and demand of remotely piloted aircraft systems (RPASs), integration of such systems into the existing airspace is becoming an issue in many countries. To assess the impact of integrated operations of manned and remotely piloted aircraft (RPA), it is necessary to perform Human-in-The-Loop (HiTL) simulations of likely situations with an integrated simulation system. This paper defines several operational concepts for the integrated simulation. Several probable scenarios were developed including a traffic pattern at a small airport and an altitude maneuver at a route crossing. HiTL simulations were performed according to the developed scenarios. The simulation results are analyzed focusing on the impacts of different communication, safety, performance, and human machine interface (HMI) characteristics of RPA.

A REVIEW OF STUDIES ON OPERATOR'S INFORMATION SEARCHING BEHAVIOR FOR HUMAN FACTORS STUDIES IN NPP MCRS

  • Ha, Jun-Su;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.247-270
    • /
    • 2009
  • This paper reviews studies on information searching behavior in process control systems and discusses some implications learned from previous studies for use in human factors studies on nuclear power plants (NPPs) main control rooms (MCRs). Information searching behavior in NPPs depends on expectancy, value, salience, and effort. The first quantitative scanning model developed by Senders for instrument panel monitoring considered bandwidth (change rate) of instruments as a determining factor in scanning behavior. Senders' model was subsequently elaborated by other researchers to account for value in addition to bandwidth. There is also another type of model based on the operator's situation awareness (SA) which has been developed for NPP application. In these SA-based models, situation-event relations or rules on system dynamics are considered the most significant factor forming expectancy. From the review of previous studies it is recommended that, for NPP application, (1) a set of symptomatic information sources including both changed and unchanged symptoms should be considered along with bandwidth as determining factors governing information searching (or visual sampling) behavior; (2) both data-driven monitoring and knowledge-driven monitoring should be considered and balanced in a systematic way; (3) sound models describing mechanisms of cognitive activities during information searching tasks should be developed so as to bridge studies on information searching behavior and design improvement in HMI; (4) the attention-situation awareness (A-SA) modeling approach should be recognized as a promising approach to be examined further; and (5) information displays should be expected to have totally different characteristics in advanced control rooms. Hence much attention should be devoted to information searching behavior including human-machine interface (HMI) design and human cognitive processes.