• Title/Summary/Keyword: Human thermal comfort

Search Result 183, Processing Time 0.024 seconds

A Study on the Evaluation Methods of Indoor Thermal Environment in Office Building (사무소건축의 실내온열환경 평가방법에 대한 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.355-359
    • /
    • 2003
  • 1. The objective of this paper is to investigate the indoor environment from the viewpoint of interaction between physical environment and the human responses. 2. A continuous measurement has been carried out for 1 year and distribution of variables have been measured for 1 day. 3. The attitude of workers was investigated by a questionnaire. 4. As the result, average luminance represented more than 800-1800 lx in the office, in contrast with less than 1000 lx in the encourage luminance of an office. 5. There was a significant difference of the occupants' response to the light environment between the neighboring environments. 6. Measured thermal conditions are on the edge of the ASHRAE comfort envelope in summer, and in the neighborhood of the lower dry limit of the envelope in spring.

  • PDF

Indoors Thermal Environment by Vertical Temperature Differences in Atrium Space (아트리움형 공간 내 수직온도차에 따른 온열환경)

  • We, Seunghwan;Lee, Jongki;Kim, Sughwan;Kim, Sumin;Chang, Jae D.
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.2
    • /
    • pp.122-128
    • /
    • 2014
  • Recently, many studies have conducted to satisfy a physical need of human between environment of light on space, so an atrium structure has been applied to cultural complex. However, this structure brings about many problems such as overheating in summer, excessive vertical temperature differences, condensation, diffusion of noise, effect of echo, and withering landscapes. Especially, in this research, thermal comfort by difference of vertical temperature in the space of atrium and the optical characteristics of glass skins of the atrium could be remarkably effected by solar flux entering indoors.

  • PDF

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

Wear Evaluation of Protective Mask according to Internal Volume (보호마스크의 내부 부피에 따른 착용 평가)

  • Eom, Ran-i;Park, Sunhee;Park, Soyoung;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.4
    • /
    • pp.626-638
    • /
    • 2020
  • In this study, protective masks were designed in varying internal volume and analyzed in regards to wearing effect. Masks were measured by surface temperature and subjective wear evaluation. Four experimental masks were created with an increasing distance between the mask center line and nose in increments. The distances were set at 0.0 cm (M0), 2.0 cm (M2), 4.0 cm (M4), and 6.0 cm (M6). The area and volume of each experimental mask was measured and both measurements had a positive correlation with the set distances. Among the experimental masks, M2 was the most breathable. The heat between the face and the mask created by exhalation was able to escape from the mask and provided the highest comfort sensation when worn. Conversely, an internal volume that is too large would decrease its comfort because repetitive breathing deforms the appearance of the mask and adversely affects its fit. Therefore, creating and maintaining the optimal internal volume of the M2 mask is important to achieve maximum thermal sensation and ease of wear.

Wearing Behavior of the Active Silver Generation to Functional Textiles Related with Gender and Age (액티브 실버층의 성별과 연령에 따른 건강 쾌적 기능성 소재 의류의 착용 행동)

  • Park, Myung-Ja;Kim, Jung-Min;Park, Jae-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.18 no.6
    • /
    • pp.1063-1075
    • /
    • 2010
  • Studying awareness, importance, satisfaction, and wearing behavior of functional textiles for active silver generation related with gender and age is expected to contribute to clothing products development to improve and maintain their health and marketing strategy fit for user characteristics. For empirical research, a survey was developed and the aged 50 and above were 332 respondents. The results of the study are as follows. First, silver generation considered all the clothing comfort sensations important when wearing clothes, such as tactile sensation, clothing pressure sensation, thermal/wet sensation, and motion sensation in human physiological aspect. Also, stretchy fabrics were ranked first in awareness, the number of wearing times, and satisfaction of comfort functional fabrics. More than 30% of silver generation have fifteen items out of 36 functional clothes. Second, in analysis of awareness by gender on functional clothing products, women were more aware of health/safety-oriented fabrics than men were. Otherwise, men had more knowledge about the water-related properties of functional fabrics than women have, such as water/moisture absorptive and water-repellent/vapor permeable fabrics. While women have more indoor casual wear, men had more active sportswear. Also, women expressed a strong preference to the stretchy function of fabrics.

Sustainable Tall Buildings: Summary of Energy-Efficient Design

  • Kheir Al-Kodmany;Mir M. Ali;Paul J. Armstrong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.107-120
    • /
    • 2023
  • Tall buildings are frequently decried as unsustainable due to their excessive energy usage. Early skyscrapers used natural light and ventilation to facilitate human comfort and applied organic materials such as stone, glass, wood, concrete, and terra cotta for cladding and finishes. With the advent of fluorescent lighting, modern heating, ventilation, air-conditioning (HVAC) systems, and thermally sealed curtain walls, tall office buildings no longer had to rely on natural light and ventilation to provide comfort. Energy efficiency was not a significant factor when the operational costs of buildings were relatively inexpensive. However, today's skyscrapers must become more energy-efficient and sustainable due to energy crises and climate change. This paper highlights vital energy-efficient design principles and demonstrates with illustrative case studies how they are applied to tall buildings in various parts of the world. It shows how sustainable environmental systems do not act alone but are integrated with advanced curtain wall systems, sky gardens, and atria, among others, to regulate and sustain thermal comfort and conserve energy.

Layering Effects on Clothing Microclimate, Clothing Insulation and Physiological Responses

  • Park, Joonhee;Yoo, Shinjung
    • International Journal of Human Ecology
    • /
    • v.14 no.2
    • /
    • pp.93-103
    • /
    • 2013
  • This study investigated the relationship of clothing microclimate and physiological responses in order to examine the layering effects on the clothing microclimate as an index to predict clothing thermal insulation ($I_{cl}$). Experiments were conducted in a $15^{\circ}C$ environment on six physically active males. Increased clothing layers resulted in higher mean temperature inside the clothing ($\bar{T}_{cl}$) and $I_{cl}$. The $I_{cl}$ had a high correlation with: $\bar{T}_{cl}$ (r = 0.556), the difference between the innermost surface temperature and the outermost surface temperature at the chest (DST) (r = 0.549) and the temperature inside clothing at the abdomen (r = 0.478). $\bar{T}_{cl}$ had the highest correlation with the temperature inside clothing at the abdomen (r = 0.889). $\bar{T}_{cl}$ also had the highest correlation with $\bar{T}_{sk}$ (r = 0.860). The results showed that the relationship between $I_{cl}$ and $\bar{T}_{cl}$ was linear (p < .01). Thermal comfort had a negative correlation with $\bar{T}_{cl-thigh}$ (r=-0.411) and $\bar{T}_{cl}$ (r = -0.323) (p < .01.)

Study on Indoor Thermal Environment Controlled by Portable Cooler (실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토)

  • Choi, Dong-Kyun;Song, Doosam;Kim, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

Evaluation of Thermoregulatory Properties of Thermal Underwear Named as 'Heating Underwear' using Thermal Manikin and Human Performance Test ('발열내복'이라 광고되는 시판 기능성 보온내복의 써멀 마네킹과 인체 착용 실험을 통한 체온조절 성능 평가)

  • Lee, Hyo-Hyun;Lee, Young-Ran;Kim, Ji-Eun;Kim, Siyeon;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.657-665
    • /
    • 2015
  • This study evaluated the thermoregulatory properties of functional thermal underwear ('heating underwear') in markets using a thermal manikin and human wear trials. One ordinary thermal underwear (ORD) and two functional thermal underwear (HEAT1 and HEAT2; manufactured goods, HEAT1: moisture absorbing heat release mechanism, HEAT2: heat storage, release mechanism) were chosen. Thermo-physiological and subjective responses were evaluated at an air temperature of $5.0{\pm}0.5^{\circ}C$ and air humidity of $30{\pm}5%RH$ with five male subjects ($21.6{\pm}1.3yr$ in age, $178.0{\pm}5.9cm$ in height, $68.2{\pm}5.9kg$ in body mass). Experimental conditions consisted of four ensembles that included winter clothes (Control: no underwear, ORD, HEAT1, HEAT2). Water-vapor resistance was greater in fabric of HEAT1 than others. The results were: 1) Total thermal insulation (IT) using a thermal manikin were not greater for HEAT1 (0.860clo) and HEAT 2 (0.873clo) than for ORD (0.886clo). 2) There were no significant differences in rectal temperature, mean skin temperature, heart rate and total body mass loss between the four conditions. Microclimate clothing temperature on the back was greater for ORD than for HEAT1 and HEAT2. Subjects felt more comfortable with HEAT1 than for others at rest. HEAT2 was higher in microclimate humidity when compared to other conditions. The results suggest that thermoregulatory properties of 'heating underwear' in market did not differ from those of ordinary thermal underwear in terms of total thermal insulation and thermoregulatory responses in a cold environment.

Research Trends for Performance, Safety, and Comfort Evaluation of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Choi, Chang-Hyun;Hong, Soon-Jung;Sung, Je-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • Background: Significant technological development and changes happened in the tractor industries. Contrariwise, the test procedures of the major standard development organizations (SDO's) remained unchanged or with a little modification over the years, demanding new tractor test standards or improvement of existing ones for tractor performance, safety, and comfort. Purpose: This study focuses on reviewing the research trends regarding performance, safety and comfort evaluation of agricultural tractors. Based on this review, few recommendations were proposed to revise or improve the current test standards. Review: Tractor power take-off power test using the DC electric dynamometer reduced human error in the testing process and increased the accuracy of the test results. GPS signals were used to determine acceleration and converted into torque. High capacity double extended octagonal ring dynamometer has been designed to measure drawbar forces. Numerical optimization methodology has been used to design three-point hitch. Numerous technologies, driving strategies, and transmission characteristics are being considered for reducing emissions of gaseous and particulate pollutants. Engine emission control technology standards need to be revised to meet the exhaust regulations for agricultural tractors. Finite Element Analysis (FEA) program has been used to design Roll-Over Protective Structures (ROPS). Program and methodology has been presented for testing tractor brake systems. Whole-body vibration emission levels have been found to be very dependent upon the nature of field operation performed, and the test track techniques required development/adaptation to improve their suitability during standardized assessment. Emphasizes should be given to improve visibility and thermal environment inside the cab for tractor operator. Tractors need to be evaluated under electromagnetic compatibility test conditions due to large growing of electronic devices. Research trends reviewed in this paper can be considered for possible revision or improvement of tractor performance, safety, and comfort test standards.