• 제목/요약/키워드: Human Neck Model

검색결과 67건 처리시간 0.026초

2D 및 3D 패턴 활용 둥근어깨 교정보조기 착용감 비교 (Comfort Evaluation of Posture Braces for Rounded Shoulders Using 2D and 3D Patterns)

  • 오미령;김남임;박진아
    • 패션비즈니스
    • /
    • 제25권3호
    • /
    • pp.71-89
    • /
    • 2021
  • The purpose of this study was to design posture braces for rounded shoulders by examining characteristics of incorrect postures of rounded shoulders. The review of information in literature on rounded shoulder postures, correction exercise methods, and posture correction devices, has prompted this study to determine the design and material of a proper posture brace for rounded shoulders. In order to develop the pattern of a posture brace for rounded shoulders for women, the study carried out a comfort evaluation of the braces based on the 2D patterns through drafting method by utilizing the body measurements and relational formulae associated with the major body measurement such as bust circumference and on the 3D patterns of the brace which were obtained from 3D human model of women in their early 20s in Korea. Differences in angles were noted when 2D and 3D patterns of shoulder posture braces were compared. The side neck point was relocated farther outside in the 3D pattern to allow additional flexibility in the back-neck area, and the shoulder band was lowered by 14.8°, increasing armhole area comfort. The upper hemline of the front panel was found to rotate upward at an angle of 22.0° as the underarm point of the 3D pattern moved upwards than the underarm point of the 2D pattern, which enhanced comfort in the abdomen area. The 3D designs of shoulder posture brace was preferred in this study, as they significantly improved comfort while conducting fit evaluation compared to the 2D patterns of shoulder posture brace.

유한요소 모델을 이용한 충격력에 따른 경추부의 응답특성 해석 (Impact Analysis of the Cervical Spin using a Finite Element Model)

  • 김영은;박덕용;이춘기
    • 한국자동차공학회논문집
    • /
    • 제7권5호
    • /
    • pp.249-257
    • /
    • 1999
  • A three dimensional finite model of a human neck has been developed in an effort to study the mechanics of cervical spin while subjected to vertical impact. This model consisting of the vertebrae from C1 through C7 including posterior element and ligaments was constructed by 2mm thick transverse CT cross-sections and X-ray film taken at lateral side. Geometrical nonlinearity was also considered for the large deformation on the disc. ABAQUS package was used for calculation and its results were verified comparing with responses of a model under static loading condition with published in-vitro experimental data. There were more cervical fracture in the restrained (compression) mode than in the nonrestrained (flexion-compression and extension-compression) mode. Upper cervical(C1-C2) injuries were observed under compression-extension modes, while lower cervical injuries occurred undjer compression-flexion modes. Posterior ligament distraction without bony damage at the upper cervical spin(C1-C2) were observed secondary to C5-C7 trauma in compression-flexion modes.

  • PDF

PIV 측정 및 수치해석을 이용한 구강암 수술에 따른 기도 형상 내 유동 특성 (Flow Characteristics in a Human Airway model for Oral Cancer Surgery by PIV Experiment and Numerical Simulation)

  • 홍현지;안세현;서희림;송재민;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.115-122
    • /
    • 2021
  • Oral cancer surgery typically consists of resection of lesion, neck dissection and reconstruction, and it has an impact on the position of hyoid bone. Therefore, morphological change of airway can occur since the geometric parameter of airway is correlated with the hyoid bone. Airflow is affected by geometry of the airway. In this study, flow characteristics were compared between pre- and post-surgery models by both particle image velocimetry (PIV) and numerical simulation. 3D model of upper airway was reconstructed based on CT data. Velocity is accelerated by the reduced channel area, and vortex and recirculation region are observed in pre- and post-surgery models. For the post-surgery model, high pressure distribution is developed by significantly decreased hydraulic diameter, and the longitudinal flow stream is also interrupted.

Development of an Effective Strategy to Teach Evolution

  • Ha, Min-Su;Cha, Hee-Young
    • 한국과학교육학회지
    • /
    • 제31권3호
    • /
    • pp.440-454
    • /
    • 2011
  • This study proposes a new instructional strategy and corresponding materials designed from various alternative frameworks to help students understand evolution as a biologically acceptable theory. Biology teachers have normally taught the evolutionary mechanism by means of comparing Lamarckism with natural selection. In this study, a new instructional strategy in which the Lamarckian explanation is first excluded because Lamarckism is known to be subsumed in a learner's cognitive structure as a strong preconception of evolution is suggested for teaching evolution. After mutation theory is introduced, Darwinism including natural selection is explained separately during the next class hour. Corresponding instructional materials that aid student understanding of the evolutionary mechanism were developed using recently published articles on human genetic traits as scientific evolutionary evidence instead of the traditional evolutionary subject matter, giraffe neck. Evolutionary evidence from human genetic traits allows students to exclude anthropocentric thoughts effectively and raise concern for the phenomenon of evolution positively. The administered instructional strategy and materials in this research improved student conception, concern, and belief of evolution and it is believed that they helped students understand the evolutionary mechanism effectively.

인대와 피팅모델의 직접계측치 비교에 의한 형태파악 연구 -18세~24세, 25세~29세를 타켓으로 하는 여성의류브랜드를 중심으로- (A Study on the Comparison of Direct Anthropometric Measurement between Dress Form and the Human Body -Focused on the 18-24 Year-Old Target Brands md 25-29 Year-Old Target Brands-)

  • 송화경;최혜선;이경미
    • 복식
    • /
    • 제54권7호
    • /
    • pp.1-14
    • /
    • 2004
  • The purpose of this study is to provide specific size data for developing a standard dress form for Korean Females between the ages of 18 and 29. Differences in sizes between dress forms used in 18-24 year-old target brands and 25-29 year-old target brands and the human body were ascertained through direct anthropometric measurements. In the 18-24 year-old target brands. 83.0-83.8cm is suitable for the bust circumference of the dress form, while in the 25-29 year-old target brands, 85.0-86.0cm is suitable. The waist circumferences of most dress forms are similar except for the Japanese C form, and there is no difference between the two groups. For hip circumference in the 18-24 year-old target brands, about 90.0cm is suitable while the 25-29 year-old target brands use additional dress forms of 91.0-92.0cm. The center front length, neck tc waist length, and front interscye breadth is 1cm shorter and the back interscye breadth is 1cm longer than indicated by the 1997 National Anthropometric Survey data.

차원 인체 스캔 데이터를 활용한 한국 중년여성 토르소 원형 설계 (Torso Pattern Design for Korean Middle-Aged Women using 3D Human Body Scan Data)

  • 김혜진;박순지
    • 한국의류산업학회지
    • /
    • 제13권4호
    • /
    • pp.600-613
    • /
    • 2011
  • The purpose of this study is to provide Torso pattern for Korean middle-aged women using 3D human body scan data. 155 women in their 40's or 50's were measured by Martin's anthropometry. Merging the data of 914 middle aged women provided by Korean agency for technology and standards, total of 1,069 subjects' data were analyzed. For data analysis, ANOVA, factor analysis and cluster analysis were done using SPSS PC+. And representative subject of each cluster was selected and they participated in 3D scanning and Torso pattern suggested for middle-aged women Torso pattern which investing the amount of ease according to each group for diffuse front interscye 30%, armscye circumference 30%, back interscye 40% using 3D human body scan data. The results of this study are as follows. Firstly, as a result of the factor analysis, the first factor was 'obesity index of body', The second factor was 'verticality size of body', The third factor was 'verticality length of upper bodice', The fourth factor was 'drop value to represent silhouette', and the fifth factor was 'physique of upper bodice'. And, middle-aged women type were classified 3 types according to the cluster analysis. Type 1(Y-type) was the long upper Torso with wide shoulder. Type 2(H-type) was flat-body type with comparatively thin upper bodice and thin lower bodice. And type 3(A-type) was the obese type with comparatively thin upper bodice and fat lower bodice. Secondly, using CAD program, point filtering was performed and approximated surface model was made. It used that generated surface smoothing corrected for abnormally extruded points and scattered points based on the curvature information. And 3D surfaces were flatted onto the plane by the internal tools of CAD program. Difference ratios of outline length and area between 3D curves and 2D plane were 0.42% and 0.54%, respectively. Third, wearing test by the sensory evaluation showed that distinct difference almost every category. The movement functionality test shows that, in all the tests which reveal significant differences, especially, 'comparison pattern A' experienced inconvenience to neck width and neck depth.

딥러닝 기반 CT 스캔 재구성을 통한 조영제 사용 및 신체 부위 분류 성능 향상 연구 (A Study on the Use of Contrast Agent and the Improvement of Body Part Classification Performance through Deep Learning-Based CT Scan Reconstruction)

  • 나성원;고유선;김경원
    • 방송공학회논문지
    • /
    • 제28권3호
    • /
    • pp.293-301
    • /
    • 2023
  • 표준화되지 않은 의료 데이터 수집 및 관리는 여전히 수동으로 진행되고 있어, 이 문제를 해결하기 위해 딥 러닝을 사용해 CT 데이터를 분류하는 연구들이 진행되고 있다. 하지만 대부분 연구에서는 기본적인 CT slice인 axial 평면만을 기반으로 모델을 개발하고 있다. CT 영상은 일반 이미지와 다르게 인체 구조만 묘사하기 때문에 CT scan을 재구성하는 것만으로도 더 풍부한 신체적 특징을 나타낼 수 있다. 이 연구는 axial 평면뿐만 아니라 CT 데이터를 2D로 변환하는 여러가지 방법들을 통해 보다 높은 성능을 달성할 수 있는 방법을 찾고자 한다. 훈련은 5가지 부위의 CT 스캔 1042개를 사용했고, 모델 평가를 위해 테스트셋 179개, 외부 데이터셋으로 448개를 수집했다. 딥러닝 모델 개발을 위해 ImageNet으로 사전 학습된 InceptionResNetV2를 백본으로 사용하였으며, 모델의 전체 레이어를 재 학습했다. 실험결과 신체 부위 분류에서는 재구성 데이터 모델이 99.33%를 달성하며 axial 모델보다 1.12% 더 높았고, 조영제 분류에서는 brain과 neck에서만 axial모델이 높았다. 결론적으로 axial slice로만 훈련했을 때 보다 해부학적 특징이 잘 나타나는 데이터로 학습했을 때 더 정확한 성능 달성이 가능했다.

A Study on the Development of E-Commerce Shipping Platform in China

  • Ying, Lou;Lee, Su-Ho;Shou, Jian-Min
    • 한국항해항만학회지
    • /
    • 제40권2호
    • /
    • pp.73-82
    • /
    • 2016
  • With the advent of Internet era, e-commerce has become the focus of human's life. It leads a new direction of social development. As the representative of traditional industry, shipping industry is confronted with a series of difficulties, which have to break through the traditional and existing model to make their business for survival. With the increasing pricking up of market competition, shipping industry is now facing development bottle neck, but e-commerce provides a new way to solve the problem. This paper firstly describes the existing forms of the e-commerce shipping platform. Secondly analyzes the data for the situation of shipping industry in China, the data for expected functions of an e-commerce shipping platform and the data for how to choose a specific e-commerce shipping platform. Thirdly analyzes the potential risks of establishing e-commerce shipping platform in China. Based on the above researched, the paper provides a suggested model of the shipping e-commerce shipping platform in China.

유한요소 모델을 이용한 중이의 소리전달 특성 해석 (Finite Element Analysis of Sound Transfer Characteristics for Middle Ear)

  • 갈영민;백무진;이두호
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1563-1571
    • /
    • 2011
  • 본 연구에서는 인간중이의 소리전달특성 계산을 위한 유한요소모델을 개발하였다. 이소골의 형상을 얻기 위하여 한국인 사체에서 추출한 측두골을 마이크로 CT 촬영하여 3 차원 입체모델로 변환하였다. 유한요소모델은 이소골, 고막, 인대와 근육 등을 포함하여 구성하였다. 유한요소모델을 이용하여 고막에서 등골족판까지의 응답함수를 계산한 후 측정값을 갖는 선행연구와 비교하였고 그 결과 10 kHz 주파수 대역까지 소리전달특성을 잘 표현하고 있음을 보였다. 또한 유한요소 모델을 구성하는 주요 물성인자의 변화에 대한 소리전달특성의 변화를 살피고 침등골관절의 강성값이 중이의 소리전달특성에 큰 영향을 미침을 보였다.

자동노출조절장치를 이용한 흉부 방사선검사 시 갑상샘 장기선량 최소화를 위한 새로운 차폐 방법에 관한 연구 (A Study on New Shielding Method for Minimizing Thyroid Oran Dose on Chest Radiography Used Automatic Exposure Control)

  • 주영철;홍동희;한범희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.323-329
    • /
    • 2020
  • The purpose of this study is to investigate the effect of radiation shielding on the thyroid organ dose and image quality during Chest PA examination using automatic exposure control system. This study was conducted in the patient posture and examination conditions such as Chest PA using human model phantom. An experiment without shielding was set as a control group (non) and the cases of using paper coated with a contrast agent (contrast) and bismuth (bismuth) were used as experimental groups. Compared to non-shielded(non), the dose at bismuth increased about 7% in C(cervical vertebrae)5 and C6 and 14% in C7 and contrast showed dose increases of about 17 to 19% in C5 and C6 and about 21% in C7. As a result of the image quality comparison, when measured in the center of the cervical vertebrae, both SNR and CNR in bismuth increased about 40% higher than non, and contrast showed about 8 to 9% improvement. Compared with soft tissues of the cervix, bismuth reduced SNR by about 15% and CNR by about 13%, in contrast, SNR decreased by 11%, and CNR decreased by about 10%. In the Chest PA using AEC, the method of using the shield in front of the collimator has the advantage to observe the anatomical structure of the neck area well compared to the method using the lead. However, the dose at the neck can be increased by 7-21% depending on shielding materials.