• Title/Summary/Keyword: How-wire Measurement

Search Result 12, Processing Time 0.028 seconds

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

A Study on the Analysis and Measurement for the Elasticity of the Catenary System (전차선로 탄성도 해석 및 측정에 관한 연구)

  • 조용현;최강윤;조기조;권삼영
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1100-1105
    • /
    • 2002
  • The elasticity of the contact wire is one of important static parameters for the catenary system. This paper presents how to analyse the elasticity of the catenary system using both simple string model method and finite element method with their formula. Analysis results obtained by these two methods for KTX catenary system are compared. A measurement of the elasticity for the KTX catenary under construction which is located near Kumkang bridge is made for the comparison with the analysis results. Both a dynamic and a static methods are tried for the measurement. Because of wave propagation, the dynamic method with 5 km/h running presented an asymmetric variational pattern of the elasticity while the static method presented a symmetric pattern of the elasticity in the span. Measured elasticity using the static method is found to be a little higher than the analysis results. But, the static method can presented us a variational pattern of the elasticity in the span similar to the analysed results. Therefore, the static method can be used for evaluating the elasticity of the catenary system

  • PDF

A study on the safety about Contact wire uplift of a metro-railroad bridge section (도시철도 교량구간의 전차선 압상량에 대한 안전성 연구)

  • Jang, Woo-Jean;Cho, Yong-Hyeon;Lee, Ki-Won;So, Sun-Young;Park, Jong-Hak;Lee, Bong-Jae
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.821-831
    • /
    • 2006
  • There are 5 railway bridges in a Seoul metro network; Jamsil, Dangsan(line 2), Dongho(line 3), Dongjak(line 4) and Chungdam(line 7). Because there are strong wind and vibration in the bridges, uplift of a contact wire caused by pantographs in the bridge section is higher than in a normal section. If the uplift at the support point exceed 10 cm, an interference between pantographs and catenary system happens. Estimated maximum uplift is obtained by applying safety factor 2 to the simulation results. The application of the safety factor is needed for taking into account of the effect of the wind, etc. Previously, we can not check whether or not the safety factor is proper. Recently, we can measure the uplift during the train operation, as a telemetry system which can measure dynamic behavior of the contact wire has been developed. The aim of this research is to review how proper the safety factor related to the uplift is, based on the measurement. We performed simulations and experiments for the uplift at the Jamsil railway bridge. The simulations were performed for the every kind of the train passing the Jamsil bridge. In order to compare the analysis results with the measurement results, we measured the uplifts at the support when the trains passed the measuring point. Finally, we proposed adequate safety factor with the uplift for the bridge section.

  • PDF

The Design and Implementation of Manhole Management System Using Wireless Communication (무선 통신을 이용한 맨홀 관리시스템 설계 및 구현)

  • Lee, Sangyoon;Lee, Yougkwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.2
    • /
    • pp.53-61
    • /
    • 2017
  • How to manage manhole is to estimate the part without observation and maintain the sewer. To get the information about current flow rate, visiting and measuring specific manhole is positively necessary. Also, there are some problems that accurate measurement of flow rate is difficult and obtaining the information about real-time whole flow rate is impossible. This thesis will easily grasp the accurate location and type of manhole to solve the problems, and provide the manhole system conveying information through direct radio communication with a manhole cover to renewal information of manhole properly. Besides, it intends to save the information about management of waterworks, maintenance of facilities, data for flow rate, and structure of manhole. Using these, it is supposed to offer how to handle manhole. Thus, this thesis delivers the information to manhole and into central servers directly without wire and provides the system and management method for effective maintenance of manhole.

Study on the Electromagnetic Coupling of Slots with Finite Thickness in the Parallel-Plate Structure

  • Sungtek Kahng;Park, Jaehoon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.111-114
    • /
    • 2001
  • In this paper, the electromagnetic coupling problems are tackled on slots with nonzero thickness. The analysis is carried out by combination of the thin-wire concept and the Method of Moment(MoM) for the sake of improving computation efficiency. Under the conditions to be presented, slots can be replaced with wires that have effective radii. Also, the infinite summation-type Green's functions are calculated for the parallel-pale structure. A slot in an infinite ground is analyzed and its results are compared with the measurement in a literature. Furthermore, it is examined how the slots couple in parallel plates.

  • PDF

Evaluation of Mechanical Property and Fatigue Damage in A Practical Superconducting Cable for Magnet (초전도 마그네트용 실용 초전도 복합선재의 기계적 특성 및 피로손상 평가에 관한 연구)

  • Sin, Hyeong-Seop;O, Sang-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.761-768
    • /
    • 2000
  • In order to investigate how the fatigue damage effects on the critical properties of superconductor, a fatigue test at room temperature and an Ic measurement test at 4.2K were carried out in this study, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable. Through the fatigue test of a 9 strand Cu-NUNbTi/Cu composite cable, a conventional S-N curve was plotted even though there was a possibility of fretting among strands. It was found that the maximum stress corresponding to the inflection point on the S-N curve obtained was nearly the same value as the yielding strength of cable obtained from the static tensile test. However, the effect of cabling in multi-strands superconducting cable on the fatigue strength was not noticeable. The critical current(Ic) measurement was carried out at 4.2K in a NbTi strand out of the fatigued cable. It showed a degradation of lc at high stress amplitude regions over 380NTa, and the degradation became significant as the applied stress amplitude increased.

Identify Modal Parameter by The Output Response of Structure Using Smart Sensor System (스마트 센서 시스템을 이용한 구조물의 모달 인자 추출)

  • Lee, Woo-Sang;Heo, Gwang-Hee;Park, Ki-Tae;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.149-160
    • /
    • 2008
  • In this study, the research was carried out on how to identify the modal parameter by acquiring the output response of the structure only through the smart sensor system. The objective of this research is to verify the performance and the on-site adaptability of the smart sensor system that have been actively researched as the advanced measuring system so far. Smart Sensor System was developed so that the real-time dynamic measurement can be performed by means of MEMS-type accelerated sensor, 8 bit CPU, wireless MODEM. In the modal parameter identification test, random excitation was added to the cantilever beam, and then the response of the structure was obtained using the smart sensor system and the wire measurement system respectively. In analyzing the data, modal parameter was identified using NExT & ERA algorithm. Furthermore, the optimal measurement location was selected through EOT algorithm in order to obtain the qualified output response. Result of the test, it was possible to verify the on-site applicability of the smart sensor.

Visualization of Flow in a Transonic Centrifugal Compressor

  • Hayami Hiroshi
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.1-6
    • /
    • 2002
  • How is the flow in a rotating impeller. About 35 years have passed since one experimentalist rotating with the impeller. of a huge centrifugal blower made the flow measurements using a hot-wire anemometer (Fowler 1968). Optical measurement methods have great advantages over the intrusive methods especially for the flow measurement in a rotating impeller. One is the optical flow visualization (FV) technique (Senoo, et al., 1968) and the other is the application of laser velocimetry (LV) (Hah and Krain, 1990). Particle image velocimetries (PIVs) combine major features of both FV and LV, and are very attractive due to the feasibility of simultaneous and multi-points measurements (Hayami and Aramaki, 1999). A high-pressure-ratio transonic centrifugal compressor with a low-solidity cascade diffuser was tested in a closed loop with HFC134a gas at 18,000rpm (Hayami, 2000). Two kinds of measurement techniques by image processing were applied to visualize a flow in the compressor. One is a velocity field measurement at the inducer of the impeller using a PIV and the other is a pressure field measurement on the side wall of the cascade diffuser using a pressure sensitive paint (PSP) measurement technique. The PIV was successfully applied for visualization of an unsteady behavior of a shock wave based on the instantaneous velocity field measurement (Hayami, et al., 2002b) as well as a phase-averaged velocity vector field with a shock wave over one blade pitch (Hayami, et al., 2002a. b). A violent change in pressure was successfully visualized using a PSP measurement during a surge condition even though there are still some problems to be overcome (Hayami, et al., 2002c). Both PIV and PSP results are discussed in comparison with those of laser-2-focus (L2F) velocimetry and those of semiconductor pressure sensors. Experimental fluid dynamics (EFDs) are still growing up more and more both in hardware and in software. On the other hand, computational fluid dynamics (CFDs) are very attractive to understand the details of flow. A secondary flow on the side wall of the cascade diffuser was visualized based either steady or unsteady CFD calculations (Bonaiuti, et al.,2002). EFD and CFD methods will be combined to a hybrid method being complementary to each other. Measurement techniques by image processing as well as CFD calculations give a huge amount of data. Then, data mining technique will become more important to understand the flow mechanism both for EFD and CFD.

  • PDF

Drag Reduction Effect by a Self-Adjustable Splitter Plate on the Flow over a Circular Cylinder (원형실린더 후류내의 가동형 와류분할판에 의한 항력 감소효과)

  • 박운진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1262-1275
    • /
    • 1993
  • The drag reduction effect of a freely-rotatable splitter plate was experimentally investigated in the 2-D wake behind a circular cylinder. By arranging the splitter plate to be aparted with a certain gap from the cylinder, the splitter plate was able to be aligned itself automatically to the flow direction in the tested range of 6.2$\times$$10^3$$\times$$10^4$. As a result, it was proven that the self-adjustable splitter plate always reduced effectively the drag imposed on the body against any arbitrary flow directions. In a specific range of Reynolds numbers, the drag reduction effect was dependent not only on the length of the splitter plate but also on the gap distance between the plate and the trailing edge of the body. For a splitter plate with a specific length, there existed a unique optimum range of gap distance to obtain successfully the drag reduction effect, however, the optimum range of gap distance was dependent on Reynolds number.

Study on the Variation of Reactive Power When Applying the Passive Filter (수동형 필터 적용시 무효전력의 변화에 관한 연구)

  • Kim, Ji-Myeong;Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.