• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.035 seconds

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House (에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성)

  • Yoo, Bok-Hee;Park, Sun-Hyo
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system - (다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 -)

  • Nan, Bao-Xuan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

ANN-Based VRF (variable refrigerant flow) system control (인공신경망 기반 VRF 시스템 제어)

  • Moon, Jin Woo
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.9-16
    • /
    • 2019
  • This study aimed at developing control algorithms for operating a variable refrigerant flow (VRF) heating and cooling system with optimal system parameter set-points. Two artificial neural network (ANN) models, which were respectively designed to predict the heating energy cost and cooling energy amount for upcoming next control cycle, was developed and embedded into the control algorithms. Performance of the algorithms were tested using the computer simulation programs - EnergyPlus, BCVTB, MATLAB in an incorporative manner. The results revealed that the proposed control algorithms remarkably saved the heating energy cost by as much as 7.93% and cooling energy consumption by as much as 28.44%, compared to a conventional control strategy. These findings support that the ANN-based predictive control algorithms showed potential for cost- and energy-effectiveness of VRF heating and cooling systems.

A Study on the Application of the Radiant Floor Cooling System in Residential Building (주거 건물의 복사냉방시스템 적용에 관한 연구)

  • 임재한;여명석;김광우
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

Standard Manual for Preventing and Maintaining Leakage of Underground Structures in Apartment Houses - Part 1. Maintenance Plan and Inspection - (공동주택 지하 구조물의 누수 예방 및 유지보수를 위한 표준 매뉴얼 - Part 1. 유지관리 계획 및 점검 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Lee, Sung Jin;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.237-238
    • /
    • 2019
  • As part of the development of building technology to improve the living performance closely related with lifestyle to Realize the Housing Welfare, the standard manual for the prevention and maintenance of water leaks in the underground structures of apartment buildings consists of Part 1 and Part 2. This study further covered the maintenance plan and inspection carried out in Part 1.

  • PDF

Marketing Strategy and Influential Factors based on the Attributes of Unit Modular System (유닛 모듈러 공법의 특성요인 분석 및 시장진출전략)

  • Kim, Domin;Lee, Jeongseok;Kim, Juhyung;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.78-86
    • /
    • 2014
  • Modular system is a construction method which installs factory-manufactured units on site. It enables to reduce the duration and improve the quality of the construction. Nevertheless, the unit modular system is restrictively applied to domestic market such as barracks, education facilities, low-rise housing. To motivate the application of unit modular system, this study figures out important attributes of the unit modular system in a domestic construction market. Finally this study suggest marketing strategies and influential factors by Importance-Performance Analysis(IPA) based on those attributes focusing on the apartment housing. As a result, Unit modular System in the domestic market has strength on constructability, but it show weakness on usability and economic aspects which are more important in apartment housing market. Thus an improved technology in usability and economic aspects are required to activate the market.

Piezoelectric Vibration Energy Harvester Using Indirect Impact (간접 충격을 이용한 압전 방식 진동형 에너지 하베스터)

  • Ju, Suna;Ji, Chang-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1499-1507
    • /
    • 2017
  • This paper presents an impact-based piezoelectric vibration energy harvester using a freely movable metal sphere and a piezoceramic fiber-based MFC (Macro Fiber Composite) as piezoelectric cantilever. The free motion of the metal sphere, which impacts both ends of the cavity in an aluminum housing, generates power across a cantilever-type MFC beam in response to low frequency vibration such as human-body-induced motion. Impacting force of the spherical proof mass is transformed into the vibration of the piezoelectric cantilever indirectly via the aluminum housing. A proof-of-concept energy harvesting device has been fabricated and tested. Effect of the indirect impact-based system has been tested and compared with the direct impact-based counterpart. Maximum peak-to-peak open circuit voltage of 39.8V and average power of $598.9{\mu}W$ have been obtained at 3g acceleration at 18Hz. Long-term reliability of the fabricated device has been verified by cyclic testing. For the improvement of output performance and reliability, various devices have been tested and compared. Using device fabricated with anodized aluminum housing, maximum peak-to-peak open-circuit voltage of 34.4V and average power of $372.8{\mu}W$ have been obtained at 3g excitation at 20Hz. In terms of reliability, housing with 0.5mm-thick steel plate and anodized aluminum gave improved results with reduced power reduction during initial phase of the cyclic testing.

Moisture Absorption and Desorption Properties of Douglas Fir, Hinoki, Larch, Plywood, and WML Board in Response to Humidity Variation

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.488-502
    • /
    • 2020
  • In this study, the moisture absorption and desorption properties presented by the Health-Friendly Housing Construction Standards of South Korea were compared using the wood of three tree species (Douglas-fir, Hinoki, Larch) and two types of wood-based materials(Plywood, WML Board). The national standards for functional building materials present that the amounts of moisture absorption and desorption should be at least 65g/㎡ on average, respectively according to the test method under KS F 2611:2009. Therefore, in this study, the moisture absorption/desorption properties of materials with no treatment (Control), with punching, and with surface stain finishing and the moisture absorption/desorption property improvement effects of the treatments were compared and analyzed. According to the results of this study, it was evaluated that all five types of wood and wood-based materials tested did not satisfy the amount of moisture absorption/desorption of at least 65g/㎡, which is the performance standard for moisture absorption/desorption functional building materials, indicating that untreated wood and wood-based materials cannot be applied as functional finishing materials according to the Health-Friendly Housing Construction Standards. The surface stain finishing greatly reduced the moisture absorption and desorption rates of the materials, and the amounts of moisture absorbed and desorbed were also shown to decrease by at least two times on average. When the surfaces of the materials were punched with Ø4mm holes at intervals of 20 mm, the moisture absorption/desorption areas increased from 18% to 51%, and this increase was shown to be capable of increasing the amounts of moisture absorbed/desorbed by 29% on average at the minimum, and 81% on average at the maximum. The effects of punching were shown to be identical even in cases where the materials were stain finished. For the application of wood or wood-based materials as eco-friendly, health-friendly, and moisture absorption/desorption functional building materials hereafter, it is judged that new physical and chemical improvement studies should be conducted, and treatment methods should be developed.

Selection of Ventilation Rate and Filter for a Residential Housing in View of Indoor Particle Concentration (공동주택의 적정 환기량 및 필터의 선정 - 실내입자농도를 중심으로 -)

  • Noh, Kwang-Chul;Jung, Yee-Kyeong;Hwang, Jung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.517-522
    • /
    • 2008
  • Ventilation rate and filter were selected to simultaneously satisfy indoor air quality and minimize energy consumption in residential housing. The concentrations of indoor particles were calculated using an adapted mass balance model for various ventilation airflow rates. To satisfy the guidelines for indoor concentrations of particles, the minimum ventilation rates of 1.0/h, 0.6/h and 0.4/h were required for MERV11, MERV13 and MERV14, respectively. And the fan power consumptions induced by ducts, a heat exchanger and a filter were calculated for various ventilation airflow rates. The increase in the ventilation rate caused a dramatic increase in the power consumption, but the filter performance did not have much of an effect on the fan power for ventilation airflow rates lower than 0.4/h. The use of the ventilation filter of MERV 14 was suggested at a ventilation rate of 0.4/h when the fan power consumptions were considered in addition to the indoor concentrations of particles and $CO_2$. The use of the MERV14 filter at a ventilation rate of 0.6/h could be more effective than the additional use of an indoor air cleaner when the residential housing unit was ventilated.

  • PDF

New Building Materials and Methods for Modernized Korean Housing (Hanok) (보급형 신한옥을 위한 부위별 공법 개발 및 영향도 분석)

  • Kim, Min;Kim, Hyosun;Ryu, Jaeseon;Jung, Youngsoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.23-32
    • /
    • 2014
  • Modernized Korean housing (Hanok) with competitive price has been actively developed due to the increased interests in traditional Korean housing. Developing new building materials and methods is an essential area for Modernized Hanok. This paper compared and analyzed two mock-up buildings of Modernized Hanok and one mock-up of Traditional Hanok those were actually constructed as test-beds. Many different new methods were introduced, and their influences on construction cost and schedule were analyzed in order to verify the research results as well as to find implications for future direction. As a result, the construction cost and schedule of Modernized Hanok have been decreased by about 40% and 20%, respectively, when compared with traditional one. 'Wood frame' and 'Roof' are found as being the most influencing areas with highest weights in terms of cost and schedule. Therefore, further development in these two areas would facilitate to reduce overall cost of Modernized Hanok with improved building performance.