• 제목/요약/키워드: Hot Water Piping

검색결과 35건 처리시간 0.026초

아파트의 온수공급배관망해석 (Analysis on Heat Supply Piping Network for Apartment House)

  • 박윤철;황광일
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

관망해석을 통한 주거용 건축물의 급수.급탕 헤더시스템 설계 방안에 관한 연구 (A Study on the Design Method of Cold & Hot Water Manifold System for Residential Buildings through the Piping Network Analysis)

  • 차민철;석호태;김동우
    • 한국주거학회논문집
    • /
    • 제19권5호
    • /
    • pp.111-120
    • /
    • 2008
  • The aim of this study is to present the design methods about manifold location being installed and size and to draw out the proper piping size as comparing the fluctuation of discharge with manifold size and residence size through the piping network analysis, when using the same faucet in accordance. The findings are summarized as follows, 1) an appropriate header main body pipe diameter was deemed to be $32{\sim}50\;mm$. 2) the research presented design measures for the application of appropriate water supply inlet pipe diameters according to residential buildings with various sizes. 3) the header direct branch piping method is ideal for small and medium-sized residential complexes, and the header branching and semi header methods are deemed to be more favorable for large residential complexes. 4) this study offered design measures for appropriate header system main body pipe diameters, water supply inlet pipe diameters, header system piping methods, application methods for functional auxiliary equipment units, and header system installation spaces and location.

동적계획법을 이용한 고온수배관의 최적보온설계에 관한 연구 (A study on the optimal design for heat insulation of hot water piping systems using a dynamic programming)

  • 유희한;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.39-52
    • /
    • 1987
  • Recently, the design problem of heat insulation have been reappraised in the aspect of energy saving due to the rising trend of energy cost. For example, that design problem is increasingly requsted in the fields of accommodation air conditioning systems, hot water supply systems, cargo handling systems, district heating or cooling systems. The rational design of heat insulation of piping systems can not only improve the overall efficiency of energy transfer but also give energy saving. In this paper, the heat insulation problem of district heating systems is therefore modeled as the multi-stage decision processes, suitable for dynamic programming technique. And take the object function as the sum of heat insulation material cost involved construction cost and heat loss cost, and propose the design method to minimize the object function for overall piping systems by dynamic programing. Effectiveness of design method presented here is proved by a computer simulation.

  • PDF

태양열 온수시스템 배관 최적설계 (Optimized Design of Piping Array in Solar Hot Water System)

  • 신정철
    • 에너지공학
    • /
    • 제22권3호
    • /
    • pp.302-306
    • /
    • 2013
  • A simple method for balancing flow rates in arrays of parallel connected flat plate solar collectors has been developed. The method is based on a computer program which solves for the flow rate through each of the collectors in a reverse return plumbed array. The analysis uses conventional "K-value" techniques and assumes the effects of density variations within the system to to be negligible. It has been found that by appropriately sizing the inlet and outlet manifolds, flow maldistribution can be nearly eliminated without resorting to expensive or complicated balancing techniques.

수소생산용 원자로에서 동심축 이중관형 1차 고온가스덕트의 예비 구조정산 (Preliminary Structural Sizing of the Co-axial Double-tube Type Primary Hot Gas Duct for the Nuclear Hydrogen Reactor)

  • 송기남;김용완
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2008
  • Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for nuclear hydrogen generation. The VHTR can produce hydrogen from heat and water by using a thermo-chemical process or from heat, water, and natural gas by steam reformer technology. A co-axial double-tube primary hot gas duct (HGD) is a key component connecting the reactor pressure vessel and the intermediate heat exchanger (IHX) for the VHTR. In this study, a preliminary design analysis for the primary HGD of the nuclear hydrogen system was carried out. These preliminary design activities include a determination of the size, a strength evaluation and an appropriate material selection. The determination of the size was undertaken based on various engineering concepts, such as a constant flow velocity model, a constant flow rate model, a constant hydraulic head model, and finally a heat balanced model.

  • PDF

사무소 건축물의 건축기계설비 배관 부속자재 요율 산출 (Calculation of the Attached-Piping-Material Rate for the Building Mechanical-Service System in Office Buildings)

  • 박률
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.185-194
    • /
    • 2017
  • Currently, in comparison with other architectural estimations, the estimation work regarding building mechanical-service systems is time-consuming, and the process is continuously becoming more difficult because of the increased usage of the attached piping materials such as fittings and hangings in addition to their complicated construction processes. To improve this problem, the Korean authority provides a simple estimation method for the attached-material rate regarding the main piping material, which is the most time-consuming work in the architectural-mechanical estimation. However, to be an applicable method on construction sites, a proper conversion rate of the attached-piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the calculation of the rate of the attached-piping materials such as the fittings and supports through the building of the mechanical-service work types of mechanical rooms, air conditioning, domestic water and hot-water supplies, and the drain-, vent-, and gas-piping work in office buildings that have been designed after 2010.

자연순환형 태양열 온수기 축열조의 압력식 설계 개조 (Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System)

  • 부준홍;정의국
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.

태양열온수기 시공설치 (Installtion of Solar Hot Water Heater)

  • 이성수
    • 태양에너지
    • /
    • 제18권2호
    • /
    • pp.51-67
    • /
    • 1998
  • 본 고에서는 우리나라 기후조건, 온수사용 패턴 등을 고려한 일반적인 태양열 이용사례를 사용용도에 따라 태양열 온수와 태양열난반시스템으로 구분하여 소개하였다. 일반적인 태양열온수기와 개념, 구성요소 등을 살펴본 후 각 종류별 작동원리를 소개하였다. 시공방법에서는 가정용과 산업용으로 구분하여 배관구성도를 포함하야 소개하였고, 설치전 여건 파악과 제품운반부터 조립, 배관, 보온, 열매체주입, 설치후 조치까지외 모든 과정을 살펴보았다. 그리고, 태양열난방시스템의 문제점도 살펴보았다.

  • PDF

원전 Mixing Tee에서의 고주기 열피로 평가 (Evaluation of High Cycle Thermal Fatigue on Mixing Tee in Nuclear Power Plant)

  • 이선기
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.22-29
    • /
    • 2020
  • In nuclear power plants, there is a risk of thermal fatigue in equipment and piping affecting system soundness because the temperature change of the system accompanies in every operation and shutdown. Therefore, in order to prevent the excess of the fatigue limit during the lifetime of plants, the fatigue limit of each piping material is determined in the designing stage. However, there are many cases where equipment or piping is locally subjected to thermal fatigue that is not considered in the design, resulting in damage to the equipment and piping, and failure during operation. Currently, local thermal fatigue generation mechanisms that are not taken into account in the design stage are gradually being identified. In this paper, the effects of the fluid temperature fluctuations on the piping soundness due to the mixing of hot and cold water, one of the local thermal fatigue generating mechanisms, were evaluated.