• Title/Summary/Keyword: Host system

Search Result 1,597, Processing Time 0.028 seconds

Dynamics Behavior of Phage-Host System Related to Microlunatus phosphovorus in Activated Sludge with Host Inoculation

  • Lee, Sang-Hyon;Otawa, Kenichi;Onuki, Motoharu;Satoh, Hiroyasu;Mino, Takashi
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.10
    • /
    • pp.1518-1522
    • /
    • 2006
  • In the present study, it was observed how the phage-host system that is naturally reproduced in activated sludge is affected by the host inoculation. The system of Microlunatus phosphovorus and its phages was selected as the phage-host system native to an activated sludge system operated for 19 days under sequencing anaerobic-aerobic conditions with glutamate as the main carbon source. The phage-host system related to M. phosphovorus was monitored by plaque assay for the phages and by fluorescent in situ hybridization (FISH) for the bacterial host. In addition, the whole phage structure was also monitored by pulsed-field gel electrophoresis (PFGE). During the first 9 days, the phage-host system was more or less steady at approx. 9% (FISH/ DAPI) for M. phosphovorus and approx. 10,000 PFU/ml for its lytic phages. Microlunatus phosphovorus JCM9379 was inoculated into the activated sludge on day 10. Right after the inoculation, M. phosphovorus was approx. 24% (FISH/DAPI) whereas its lytic phages dropped down to approx. 500 PFU/ ml. After the host inoculation (within 9 days), however, the phage-host system eventually reverted to its original level in each population. On the other hand, the whole phage structure was not significantly changed by M. phosphovorus inoculation but stable throughout the process operation. Only the minor change that four phage groups gradually became abundant after the host inoculation was observed.

OPTIMAL CONTROL PROBLEM FOR HOST-PATHOGEN MODEL

  • P. T. Sowndarrajan
    • Nonlinear Functional Analysis and Applications
    • /
    • v.28 no.3
    • /
    • pp.659-670
    • /
    • 2023
  • In this paper, we study the distributed optimal control problem of a coupled system of the host-pathogen model. The system consists of the density of the susceptible host, the density of the infected host, and the density of pathogen particles. Our main goal is to minimize the infected density and also to decrease the cost of the drugs administered. First, we prove the existence and uniqueness of solutions for the proposed problem. Then, the existence of the optimal control is established and necessary optimality conditions are also derived.

Ubiquitin-regulating effector proteins from Legionella

  • Jeong, Minwoo;Jeon, Hayoung;Shin, Donghyuk
    • BMB Reports
    • /
    • v.55 no.7
    • /
    • pp.316-322
    • /
    • 2022
  • Ubiquitin is relatively modest in size but involves almost entire cellular signaling pathways. The primary role of ubiquitin is maintaining cellular protein homeostasis. Ubiquitination regulates the fate of target proteins using the proteasome- or autophagy-mediated degradation of ubiquitinated substrates, which can be either intracellular or foreign proteins from invading pathogens. Legionella, a gram-negative intracellular pathogen, hinders the host-ubiquitin system by translocating hundreds of effector proteins into the host cell's cytoplasm. In this review, we describe the current understanding of ubiquitin machinery from Legionella. We summarize structural and biochemical differences between the host-ubiquitin system and ubiquitin-related effectors of Legionella. Some of these effectors act much like canonical host-ubiquitin machinery, whereas others have distinctive structures and accomplish non-canonical ubiquitination via novel biochemical mechanisms.

Development of Multiple Fault Diagnosis Methods for Intelligence Maintenance System (지적보전시스템의 실시간 다중고장진단 기법 개발)

  • Bae, Yong-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2004
  • Modern production systems are very complex by request of automation, and failure modes that occur in thisautomatic system are very various and complex. The efficient fault diagnosis for these complex systems is essential for productivity loss prevention and cost saving. Traditional fault diagnostic system which perforns sequential fault diagnosis can cause catastrophic failure during diagnosis when fault propagation is very fast. This paper describes the Real-time Intelligent Multiple Fault Diagnosis System (RIMFDS). RIMFDS assesses current machine condition by using sensor signals. This system deals with multiple fault diagnosis, comprising of two main parts. One is a personal computer for remote signal generation and transmission and the other is a host system for multiple fault diagnosis. The signal generator generates various faulty signals and image information and sends them to the host. The host has various modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault diagnosis and graphic representation of the results. RIMFDS diagnoses multiple faults with fast fault propagation and complex physical phenomenon. The new system based on multiprocessing diagnoses by using Hierarchical Artificial Neural Network (HANN).

A Development of Modular Monitoring System for Wind Turbine Test Site (풍력 실증단지를 위한 분산 형 모니터링 시스템 개발)

  • Lee Jeong Wan;Yoo Neung Soo;Nam Yoon Su;Cho Byung Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.9-12
    • /
    • 2005
  • In this paper. we offer a new monitoring system that controls all of the windfar. it can also apply use general wind turbine systems and real meteorological tower. We propose a hierarchical releiable monitoring system connected by wireless communication channels between monitoring host computer and modular slave measuring subsystems. Our system has two hierarchical subsystems: slave measuring systems, and supervisory host computer. We design and implement that the slave measuring subsystems is placed in meteorological tower and wind turbines, and the supervisory host computer in safety zone, The micro-controller in slave measuring system is duplicated using cold-standby method for reliability. The host computer and slave system constructs a feedback system, with wireless communication channel between them. For monitoring and command function, the supervisory computer is implemented with a Personal Computer using graphic user interface. Consequently. we can get a reliable but economic system.

  • PDF

The development of a micro robot system for robot soccer game (로봇 축구 대회를 위한 마이크로 로봇 시스템의 개발)

  • 이수호;김경훈;김주곤;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.507-510
    • /
    • 1996
  • In this paper we present the multi-agent robot system developed for participating in micro robot soccer tournament. The multi-agent robot system consists of micro robot, a vision system, a host computer and a communication module. Mcro robot are equipped with two mini DC motors with encoders and gearboxes, a R/F receiver, a CPU and infrared sensors for obstacle detection. A vision system is used to recognize the position of the ball and opponent robots, position and orientation of our robots. The vision system is composed of a color CCD camera and a vision processing unit. Host computer is a Pentium PC, and it receives information from the vision system, generates commands for each robot using a robot management algorithm and transmits commands to the robots by the R/F communication module. And in order to achieve a given mission in micro robot soccer game, cooperative behaviors by robots are essential. Cooperative work between individual agents is achieved by the command of host computer.

  • PDF

Multiple LCD System Development of daisy-chain Method using LVDS (LVDS를 이용한 daisy-chain 방식의 다중 LCD 시스템 개발)

  • Kim, Jae-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2747-2754
    • /
    • 2012
  • This thesis explains the development of multiple LCD system with the additional function to maximize the utilization of PC contents. The newly developed system is composed of host LCD and slave LCD. Host LCD decodes and outputs the image and voice of NTSC, PAL, SECAM signals. It also converts the decoded signals into LVDS signals before transmitting them to slave LCD stage. In addition, the installation of CF Memory and USB Memory helps display multi-media data. Unlike the host LCD, since not including the tuner and memory part, the slave LCD can't receive TV signals and play video signals. It only has the function to receive LVDS image signals and display on a LCD panel. This newly developed multi-LCD system has competitiveness in various aspects. With its simple structure, the failure rate, price and display power are relatively low due to its simplification of the control part. It has price and functional competitiveness as the product whose host LCD can control the entire slave LCD in terms of channel, volume, and video output.

Web Application Awareness using HTTP Host (HTTP Host를 이용한 웹 어플리케이션 인식에 관한 연구)

  • Choi, Ji Hyeok;Kim, Myung Sup
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.8
    • /
    • pp.327-334
    • /
    • 2013
  • Today's network traffic has become extremely complex and diverse since the speed of network became faster and a variety of application services appear. Moreover, many applications appear and disappear fast and continuously. However, the current traffic classification system does not give much attention to this dynamic change of applications. In this paper, we propose an application awareness system in order to solve this problem. The application awareness system can provide the information, such as the usage trend of conventional applications and the emergence of new applications by recognizing the application name in a rapidly changing network environment. In order to recognize the application name, the Host field of HTTP protocol has been utilized. The proposed mechanism consists of two steps. First, the system generates the candidates of application name by extracting the domain name from the Host field in HTTP packet. Second, the administrator confirms the name afterward. The validity of the proposed system has been proved through the experiments in campus network.

A Study on Detection Method of Multi-Homed Host and Implementation of Automatic Detection System for Multi-Homed Host (망혼용단말 탐지방법에 대한 연구 및 자동탐지시스템 구현)

  • Lee, Mi-hwa;Yoon, Ji-won
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.2
    • /
    • pp.457-469
    • /
    • 2018
  • This study aimed to investigate the fundamental reasons for the presence of multi-homed host and the risks associated with such risky system. Furthermore, multi-homed host detection methods that have been researched and developed so far were compared and analyzed to determine areas for improvement. Based on the results, we propose the model of an improved automatic detection system and we implemented it. The experimental environment was configured to simulate the actual network configuration and endpoints of an organization employing network segmentation. And the functionality and performance of the detection system were finally measured while generating multi-homed hosts by category, after the developed detection system had been installed in the experiment environment. We confirmed that the system work correctly without false-positive, false-negative in the scope of this study. To the best of our knowledge, the presented detection system is the first academic work targeting multi-homed host under agent-based.