The measurement and management of patient satisfaction has become one of the key issues in the last two decades. Hospitals must thoroughly understand the needs of their customers and design products and health services that meet and exceed their expectations. The importance-performance analysis(IPA) is a widely used analytical technique that yields strategies for managing customer satisfaction in a variety of applications. IP A is a two-dimensional grid based on customer-perceived importance of quality attributes and attribute performance. Depending on the interplay of these two dimensions, four strategies can be derived. The aim of this study is to develop the management strategies for improving patient satisfaction in university hospitals using the I-P analysis. The attributes on inpatient service quality in 4 university hospitals was investigated using the Martilla and James(l977)' s a mean adjusted I-P grid where the axes of the grid cross at the average rating point of all items. The patient satisfaction questionnaires were completed by 600 hospital inpatients. The main statistical methods are path analysis and IPA with SPSS 12.0 and AMOS 4.0 statistical softwares. The two attributes, physician and medical service, administrative staff kindness attributes position in first quadrant(Keep Up the Good domain). The nurse and nursing service attributes position in second quadrant(Possible Overkill domain). The two attributes, convenience of check-in service, facilities and physical environment position in third quadrant(Low Priority domain). Finally the quality of inpatient service(food etc.) attributes position in fourth quadrant(Concentrate Here domain). These findings show various implications on the development of strategies in university hospitals in the future. It was determined that quality of inpatient service(food etc.) need to concentrate more on investments. These investments include a taste, price, proper provision of food service and quick response of pain management. A low priority was given to investment in streamlining the check-in process of inpatient and hospital facilities and physical environment in the long run.
Objectives : This study was performed to evaluate inter-rater and intra-rater reliability of interpretation and reproducibility of a pulse analyser (MAXMAC27-Plus). Methods : 38 of 40 volunteers completed the pulse analysis consecutively. Three Korean medical doctors who had at least 2 years of clinical experience interpreted the pulse waves for 3 aspects of size, depth and shape, then inter-rater reliability and crude agreement was obtained. Reinterpretation was done 2 weeks later and intra-rater reliability and crude agreement was obtained. Intra-rater reliability and crude agreement between 1st and 2nd measurement was calculated. Cohen's weighted kappa for size, Cohen's kappa for depth and shape were used as statistical analysis. Results : Inter-rater reliability of size, depth and shape among 3 raters was 0.598, 0.604, and 0.312, respectively, showing moderate to substantial agreement. Average intra-rater reliability between 1st and 2nd interpretation of size, depth and shape was 0.806, 0.705, and 0.638, respectively, showing substantial to almost perfect agreement. However, intra-rater reliability between consecutive measurements of size, depth and shape was 0.221, 0.121, and 0.194, respectively, which showed only poor to fair agreement. Conclusions : Intra-rater and inter-rater reliability of one pulse wave showed relatively high concordance. Training by a clinical expert may effect better concordance among raters. Test-retest reliability showed poor agreement. Improvement of measurement technique and device performance will be needed.
Electrosurgical Unit(ESU) is medical equipment that cut or coag tissues using electrical energy. It is used in hospitals' outpatient clinic room and operating room. Improper use of an ESU may cause fatal injuries to the patient, such as burns. So, before using an ESU, make sure that it is supplying enough energy for cut and coag by measuring the output power and checking the output power cable. In this study, we developed a simple ESU power measurement system PW100 that allows anyone to check the basic output power. And PW100 can check the state of the cable associated with the output power before using ESU. Then, we compared the measured output power of the PW100 with an ESU Analyzer which was commercialized, and compared the performance. In the experiment, the output power measured by the PW100 was lower value than an ESU Analyzer's that. However, the PW100's output power measured in the 5% error range and showed stable reproducibility by a low %RSD value.
Kim, Jung Ho;Chi, Seong In;Kim, Hyun Jeong;Seo, Kwang-Suk
Journal of Dental Anesthesia and Pain Medicine
/
제18권2호
/
pp.97-103
/
2018
Background: Respiration monitoring is necessary during sedation for dental treatment. Recently, acoustic respiration rate ($RRa^{TM}$), an acoustics-based respiration monitoring method, has been used in addition to auscultation or capnography. The accuracy of this method may be compromised in an environment with excessive noise. This study evaluated whether noise from the ultrasonic scaler affects the performance of RRa in respiratory rate measurement. Methods: We analyzed data from 49 volunteers who underwent scaling under intravenous sedation. Clinical tests were divided into preparation, sedation, and scaling periods; respiratory rate was measured at 2-s intervals for 3 min in each period. Missing values ratios of the RRa during each period were measuerd; correlation analysis and Bland-Altman analysis were performed on respiratory rates measured by RRa and capnogram. Results: Respective missing values ratio from RRa were 5.62%, 8.03%, and 23.95% in the preparation, sedation, and scaling periods, indicating an increased missing values ratio in the scaling period (P < 0.001). Correlation coefficients of the respiratory rate, measured with two different methods, were 0.692, 0.677, and 0.562 in each respective period. Mean capnography-RRa biases in Bland-Altman analyses were -0.03, -0.27, and -0.61 in each respective period (P < 0.001); limits of agreement were -4.84-4.45, -4.89-4.15, and -6.18-4.95 (P < 0.001). Conclusions: The probability of missing respiratory rate values was higher during scaling when RRa was used for measurement. Therefore, the use of RRa alone for respiration monitoring during ultrasonic scaling may not be safe.
Yong Jun Choi;Hye Jung Park;Jae Hwa Cho;Min Kwang Byun
Tuberculosis and Respiratory Diseases
/
제86권4호
/
pp.272-283
/
2023
Background: In patients with chronic obstructive pulmonary disease (COPD), decreased muscle mass is a frequently encountered comorbidity in clinical practice. However, the evaluation of muscle mass in patients with COPD in real-world practice is rare. Methods: We retrospectively reviewed the electronic medical records of all patients with COPD who underwent bioelectrical impedance analysis at least once between January 2011 and December 2021 in three hospitals. Then, we analyzed the performance rate of muscle mass measurement in the patients and the correlation between muscle mass, clinical parameters, and COPD prognosis. Results: Among the 24,502 patients with COPD, only 270 (1.1%) underwent muscle mass measurements. The total skeletal muscle mass index was significantly correlated with albumin, alanine transaminase, and creatinine to cystatin C ratio in patients with COPD (r=0.1614, p=0.011; r=0.2112, p=0.001; and r=0.3671, p=0.001, respectively). Acute exacerbation of COPD (AE COPD) was significantly correlated with muscle mass, especially the truncal skeletal muscle mass index (TSMI) in males (r=-0.196, p=0.007). In the multivariate analysis, TSMI and cystatin C were significant risk factors for AE COPD (hazard ratio, 0.200 [95% confidence interval, CI, 0.048 to 0.838] and 4.990 [95% CI, 1.070 to 23.278], respectively). Conclusion: Low muscle mass negatively affects the clinical outcomes in patients with COPD. Despite its clinical significance, muscle mass measurement is performed in a small proportion of patients with COPD. Therefore, protocols and guidelines for the screening of sarcopenia in patients with COPD should be established.
Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
한국의학물리학회지:의학물리
/
제33권4호
/
pp.150-157
/
2022
Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.
목 적 : 측정을 통한 장치의 성능관리 평가로 임상실무에서의 능력배양과 정확한 관전압, 조사시간, 출력선량을 측정하는 기술을 익히고 병원에서 사용 중인 간접촬영용 X-선 발생장치 성능현황을 파악하기 위함이다. 재료 및 방법 : 관전압, 조사시간, 출력선량 측정기를 이용하여 10개 대학병원 간접촬영용 X-선 발생장치(원내,외 각 10대)를 이용하였다. 결 과 : 관전압 정확도 시험 PAE 판정에 의해 부적합한 간접촬영기는 3대가 나왔으며, 조사시간의 정확도 시험에서는 2대, 또한 조사선량의 재현성 시험에서도 조사선량에 대한 변동계수를 계산한 결과 3대가 나왔다. 3가지 성능검사에서 원외(이동차량)의 부적합한 간접촬영기는 5대, 원내는 3대로 원외(이동차량)의 간접촬영기가 원내보다 부적합한 것이 높게 나타났다. 결 론 : 간접촬영기의 성능을 일정하게 유지함으로서 방사선 피폭경감, 화질관리, 재촬영 감소 등에 의해 환자에게 양질의 의료서비스를 제공할 수 있는 여건을 마련할 수 있을 것이다. 따라서 정기적인 성능검사가 필요하다고 사료된다.
Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.
Purpose. To understand the effectiveness of training programs to improve the daily living activities and social adaption abilities of stroke patients. Methods. The participant included 1 stroke patient in Jeonbuk, from March to August 2016. The test tools used was the Canadian occupational performance measurement, International classification of function, disability and health co-resets. After applying the training program, I compared the daily life satisfaction and social adaption abilities. Results. According to this study, both daily life satisfaction and social adaption abilities improved. Conclusion. In conclusion, after an exercise program, self- help program, and underwater exercise programs, daily life satisfaction and social adaptation levels were improved. Therefore, the programs that apply to stroke patients could be found to be effective.
We performed the cross-cultural adaptation process directed at the translation into Korean of the Pain Visual Analogue Scale, the Self-Report of Improvement and the Beacke Physical Activity Questionnaire for Older Adults. This project will help ensure that the Korean versions of these measures retain their meaning and measurement properties when applied to the Korean language and culture. This will help reduce measurement error in the RCT. This research should be of value to other researchers who wish to study older adults with rheumatological conditions.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.