• 제목/요약/키워드: Hospital Power Consumption

검색결과 27건 처리시간 0.029초

인버터식 X선발생장치용 고주파 공진형 고압변압기 등의 설계 (Design of High Frequency Resonant High-tension Transformer in Inverter Type X-Ray Generator)

  • 이성길;최성관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.5-11
    • /
    • 2001
  • Most of X-ray generator had used rectifier type transformer with high tension generator which is supplied in a clinical diagnosis. Because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. In these days, high tension generator for inverter type X-ray generator is being supplied from a broad which uses semi-conductor switching element for the electric power that have a high speed switching ability to solve these problem. But, semi-conductor element with large capacity is used with X-ray tube's large consumption power and diffusion is difficult in the small size hospital because production cost is going up by doing digital control through DSP. Therefore, this paper designed and manufactured CR type voltage divider for feedback control of tube voltage with high frequency resonance type inverter and for high tension transformer with high frequency. It was to make economical diffusion type X-ray generator which has wide output voltage and load extent. It was preyed that the X-ray generator had the stability of X-ray tube's output characteristics.

  • PDF

병원 건물에 설치된 냉각탑 병용 지열 히트펌프 시스템의 냉방 성능 (Cooling Performance of Cooling Tower-Assisted Ground-Coupled Heat Pump (GCHP) System Applied in Hospital Building)

  • 손병후;이두영;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권1호
    • /
    • pp.7-16
    • /
    • 2016
  • This paper presents the measurement and analysis results for the cooling performance of ground-coupled heat pump (GCHP) system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from May 1 to October 30, 2014. The results showed that the entering source temperature of brine returning from the ground heat exchanger was in a range of design target temperature. Leaving load temperatures to building showed an average value of $11.4^{\circ}C$ for cooling season. From the analysis, the daily performance factor (PF) of geothermal heat pumps ranged from 4.4 to 5.2, while the daily PF of hybrid GCHP system varied from 3.0 to 4.0 over the entire cooling season.

슬라이딩모드 제어기를 이용한 보행 훈련 로봇 팔의 힘제어 (Force Control of an Arm of Walking Training Robot Using Sliding Mode Controller)

  • 신호철;강창회;정승호;김승호
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.38-44
    • /
    • 2002
  • A walking training robot is proposed to provide stable and comfortable walking supports by reducing body weight load partially and a force control of an arm of walking training robot using sliding mode controller is also proposed. The current gait training apparatus in hospital are ineffective for the difficulty in keeping constant unloading level and for the constraint of patients' free walking. The proposed walking training robot effectively unloads body weight during walking. The walking training robot consists of an unloading manipulator and a mobile platform. The manipulator driven by an electro-mechanical linear mechanism unloads body weight in various levels. The mobile platform is wheel type, which allows patients to walt freely. The developed unloading system has advantages such as low noise level, lightweight, low manufacturing cost and low power consumption. A system model fur the manipulator is established using Lagrange's equation. To unload the weight of the patients, sliding mode control with p-control is adopted. Both control responses with a weight and human walking control responses are analyzed through experimental implementation to demonstrate performance characteristics of the proposed force controller.

ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구 (A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG)

  • 강범선;최기상
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Journal of Audiology & Otology
    • /
    • 제23권3호
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • 대한청각학회지
    • /
    • 제23권3호
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

폐경비만여성의 골밀도와 골대사 지표 및 식사의 질 상관성 조사 (Relationship between Bone Mineral Density and Bone Metabolic Biochemical Markers and Diet Quality Index-International(DQI-I) in Postmenopausal Obese Women)

  • 정연아;김미성;신새론;한아름;서검석;손정민
    • 대한지역사회영양학회지
    • /
    • 제21권3호
    • /
    • pp.284-292
    • /
    • 2016
  • Objectives: This study compared the differences of postmenopausal women's bone mineral density in relation to the degree of obesity, metabolism index and dietary factors that affect bone mineral density. Methods: The subjects included in the study are 39 postmenopausal women of normal weight with body mass index less than $25kg/m^2$ and 32 postmenopausal who are obese. Anthropometry and biochemical analysis were performed and nutrient intakes and DQI-I were assessed. Results: Normal weight women were $56.03{\pm}3.76years$ old and obese women were $58.09{\pm}5.13years$ old and there was no significant difference in age between the two groups. The T-score of bone mineral density was $0.03{\pm}1.06$ in normal weight women and $-0.60{\pm}1.47$ in obese women and this was significantly different between the two groups (p<0.05). Blood Leptin concentration was significantly lower in normal weight women ($6.09{\pm}3.37ng/mL$) compared to obese women in ($9.01{\pm}4.99ng/mL$) (p<0.05). The total score of diet quality index-international was $70.41{\pm}9.34$ in normal weight women and $64.93{\pm}7.82$ in obese women (p<0.05). T-score of bone mineral density showed negative correlations with percentage of body fat (r = -0.233, p=0.05), BMI (r = -0.197, p=0.017), triglyceride (r = -0.281, p=0.020) and leptin (r = -0.308, p=0.011). The results of multiple regression analysis performed as the method of entry showed that with 22.0% of explanation power, percentage of body fat (${\beta}=-0.048$, p<0.05), triglyceride (${\beta}=-0.005$, p<0.05) and HDL-cholesterol (${\beta}=0.034$, p<0.01), moderation of DQI-I (${\beta}=-0.231$, p<0.05) affected T-score significantly. Conclusions: The results of the study showed that obese women have less bone density than those with normal weight women. In addition, the factor analysis result that affect bone mineral density showed that intake of fat is a very important factor. Therefore, postmenopausal women need to maintain normal weight and manage blood lipid levels within normal range. They also need to take various sources of protein and reduce consumption of empty calorie foods that have high calories, fat, cholesterol and sodium.

ZigBee를 이용한 뇌졸중 치료용 무선 전기 자극기 개발 (Development of Wireless Neuro-Modulation System for Stroke Recovery Using ZigBee Technology)

  • 김국화;유문호;신용일;김형일;김남균;양윤석
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.153-161
    • /
    • 2007
  • Stroke is the second most significant disease leading to death in Korea. The conventional therapeutic approach is mainly based on physical training, however, it usually provides the limited degree of recovery of the normal brain function. The electric stimulation therapy is a novel and candidate approach with high potential for stroke recovery. The feasibility was validated by preliminary rat experiments in which the motor function was recovered up to 80% of the normal performance level. It is thought to improve the neural plasticity of the nerve tissues around the diseased area in the stroked brain. However, there are not so much research achievements in the electric stimulation for stroke recovery as for the Parkinson's disease or Epilepsy. This study aims at the developments of a wireless variable pulse generator using ZigBee communication for future implantation into human brain. ZigBee is widely used in wireless personal area network (WPAN) and home network applications due to its low power consumption and simplicity. The developed wireless pulse generator controlled by ZigBee can generate various electric stimulations without any distortion. The electric stimulation includes monophasic and biphasic pulse with the variation of shape parameters, which can affect the level of recovery. The developed system can be used for the telerehabilitation of stroke patient by remote control of brain stimulation via ZigBee and internet. Furthermore, the ZigBee connection used in this study provides the potential neural signal transmission method for the Brain-Machine Interface (BMI).

EEF 기반의 U-Health 시스템 설계 (Design of U-Health System based on Embedded Event Filtering)

  • 김재인;나철수;한대영;김대인;황부현
    • 한국콘텐츠학회논문지
    • /
    • 제9권2호
    • /
    • pp.88-96
    • /
    • 2009
  • 본 논문에서는 U-Health 시스템의 효율성을 높이는 EEF 기법을 제안하고 이를 적용하여 심전도 센서를 이용한 U-Health 시스템 설계에 대하여 기술한다. EEF 기법은 센서노드가 이상 데이터 수집 시에만 베이스 노드로 데이터를 전송하는 기법이다. 이러한 기법은 센서노드의 통신 빈도수를 줄여 전력 소모를 최소화 하고 여러 환자의 데이터를 수집해야 하는 베이스 노드의 처리 부담을 감소시키는 장점을 갖는다. 본 논문에서 제안하는 EEF를 적용한 U-Health 시스템은 심전도 센서와 GPS 센서를 통하여 환자의 심전도 상태 정보와 환자의 위치 정보를 서버로 전송한다. 서버는 환자의 이상 유무를 판단하고 병원의 단말기로 환자의 상태와 위치를 전송하는 구조로 동작하며 시뮬레이션을 통해 EEF 기법의 U-Health 시스템에 대한 적합성을 확인하였다.

이중모드 주사기형 약물자동주입장치의 개발에 관한 연구 (Development of the Dual Mode Syringe Type Infusion Pump)

  • 홍수용;엄기현;김익근;이경중;윤형로;김은기;엄대자
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.317-318
    • /
    • 1998
  • The purpose of this study is to design and develop the circuit of the dual mode syringe pump. Syringe pump is used in intensive care unit, delivery room, pediatric room, operating theater and other fields of hospital at present. Normally the syringe pump delivers one medicine in one case, but in case of intensive care unit, it is necessary to deliver more than two kinds of medicines at a time. Therefore we have designed dual mode syringe pump. We used RISC type microcontroller, PIC17C44 as master controller, and PIC16C73 as slave cpu using for the low power consumption. The performance of system is evaluated by analysis of the linearity and accuracy which is the most important factors in application. While the proposed system shows a acceptable linearity and accuracy, a further research about reducing the errorr should be done.

  • PDF