• Title/Summary/Keyword: Horizontal type

Search Result 1,348, Processing Time 0.03 seconds

Effect of a frontal impermeable layer on the excess slurry pressure during the shield tunnelling in the saturated sand (포화 사질토에서 전방 차수층이 쉴드터널 초과 이수압에 미치는영향)

  • Lee, Yong-Jun;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.347-370
    • /
    • 2011
  • Slurry type shield would be very effective for the tunnelling in a sandy ground, when the slurry pressure would be properly adjusted. Low slurry pressure could cause a tunnel face failure or a ground settlement in front of the tunnel face. Thus, the stability of tunnel face could be maintained by applying an excess slurry pressure that is larger than the active earth pressure. However, the slurry pressure should increase properly because an excessively high slurry pressure could cause the slurry flow out or the passive failure of the frontal ground. It is possible to apply the high slurry pressure without passive failure if a horizontal impermeable layer is located in the ground in front of the tunnel face, but its location, size, and effects are not clearly known yet. In this research, two-dimensional model tests were carried out in order to find out the effect of a horizontal impermeable layer for the slurry shield tunnelling in a saturated sandy ground. In tests slurry pressure was increased until the slurry flowed out of the ground surface or the ground fails. Location and dimension of the impermeable layer were varied. As results, the maximum and the excess slurry pressure in sandy ground were linearly proportional to the cover depth. Larger slurry pressure could be applied to increase the stability of the tunnel face when the impermeable layer was located in the ground above the crown in front of the tunnel face. The most effective length of the impermeable grouting layer was 1.0 ~ 1.5D, and the location was 1.0D above the crown level. The safety factor could be suggested as the ratio of the maximum slurry pressure to the active earth pressure at the tunnel face. It could also be suggested that the slurry pressure in the magnitude of 3.5 ~4.0 times larger than the active earth pressure at the initial tunnel face could be applied if the impermeable layer was constructed at the optimal location.

Study of silk lousiness (I) (견사 Lousiness에 대한 연구 (I))

  • 최병희;김낙정;박광의;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.3
    • /
    • pp.1-11
    • /
    • 1963
  • This treatise is to set up a fundamental condition of checking silk lousiness and to set up a new improving method of cocoon bave lousiness after super refining treatment. It is also studied whether silk lousiness can be eliminated through the observation of the silk gland, or the lousiness can be able to improve through such a study. The conclusions obtained in this paper are as follows. 1. Silk lousiness is able to be observed most properly when the light direction and the fiber direction are parallel in plan view of the silk cloth and the greater the angle between them is, the less the lousiness is observed. When, however, the angle is greater than some specific angle(30$^{\circ}$), no more lousiness is observed. This specific angle is named by the author as Lousiness Horizontal Critical Angle. 2. Silk lousiness can be observed when the angle of light incidence against the silk cloth is six degrees, while the larger the angle is, the less the lousiness is observed. When, however, the angle is greater than same specific angle(45$^{\circ}$) the lousiness disappears. Such a specific angle is named by the author as Lousiness Vertical Critical Angle. 3. The best textile composition to decrease lousiness defect is plan weave, while twill and satin weave show more lousiness with the same silk fiber. 4. Lousiness was classified as Lousiness A, B, ana C of which A was the general lousiness, B was the group type, and C was the glucose type and the standard photographs for the lousiness grading of these types were prepared. 5. The proper soap-refining hours of silk for lousiness test was eight hours. 6. The greater the difference of fiber diameter between the cocoon single bave and the splitend was, the more lousiness was composed. The normal splitends were measured as 1/4-1/5 of the main fiber. 7. The lousiness was found at the cocoon shape ends more than other parts, and found at the middle cocoon layer than other layer which was imagined to be as a result of poor uniform bave spinning of silk worm. 8. Female cocoon had more lousiness than the male cocoon. 9. It was found that there was a great possibility to have the splitends through the observation of the anatomical silkgland, and the author reached a conclusion that the lousiness can be improved to a certain degree only by the elimination of abnormal silk gland from the breeding aspects. 10. The cocoon bave of the offspring after super refining lousiness test and selection showed more improved lousiness defect than that of the parents.

  • PDF

Experimental Study on Two-Seam Cold Formed Square CFT Column to Beam Connections with Asymmetric Diaphragms (상하 이형 다이아프램으로 보강된 2심 냉간성형 각형 CFT 기둥-보 접합부의 실험적 연구)

  • Oh, Heon Keun;Kim, Sun Hee;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.35-45
    • /
    • 2013
  • The concrete-filled tube column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. It suggests that pipe should be produced by welding two sides together where two shapes are joined after a channel is pre-welded onto the three sides in order to form an internal diaphragm. The upper diaphragm of the connection used the horizontal plate and the lower diaphragm used the Vertical plate. This research performed 6 monotonic tension experiments describing the connection upside and downside in order to evaluate the structural capability of the offered connection. And the cyclic loading experiment was performed about 2 T-Type column to beam connections. As to the experimental result edge cutting geometry, there was no big effect. An increase in the number of holes of the plate ultimate strength was increased by 5% and The thickness of the plate increases, the maximum strength was increased by 4%. T-Type connections until it reaches the plastic moment showed a stable behavior.

A study on the factor analysis by grade for highway traffic accident (고속도로 교통사고 심각도 등급별 요인분석에 관한 연구)

  • Lee, Hye-Ryung;Kum, Ki-Jung;Son, Seung-Neo
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.157-165
    • /
    • 2011
  • With respect to the trend of highway traffic accident, highway accident is in decline, whileas, the fatality is on an increasing trend. Thus, many efforts to decrease highway traffic accidents and improve the safety, are required. In particular, in case of highway, the management standard by grade for accident black spot is designated. Thus, investing the effect factors by grade for highway traffic accident is required in detail. Thus, in this study, the factors affecting the traffic accidents among the environmental factors based on the graded data for the accident black spot in the applicable section targeting the Seoul-Pusan Express Highway, were reviewed; accident forecasting model which would analyze the characteristics of the accidents for determining the accident grade, was developed. As a result of establishing a model by using Quantification Theory of Type II, considering the characteristics of the dependent and independent variables based on the geometric structure, 'the fixed variable' among the variables relating to the accident, for the variables influencing over the accident grade, 'the type of vans, a chassis and people', 'the trailers, special vehicles and chassis people' and 'the negligence of watching and cloudy weather' were analyzed as common factors, in case of 'horizontal alignment', 'longitudinal slope' and, 'barricade' respectively.

Growth and effect of thermal annealing for $AgGaS_2$ single crystal thin film by hot wall epitaxy (Hot wall epitaxy(HWE)법에 의한 $AgGaS_2$ 단결정 박막 성장과 열처리 효과)

  • Moon Jongdae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • A stoichiometric mixture of evaporating materials for AgGaS₂ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, AgGaS₂ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were 590℃ and 440℃, respectively. The temperature dependence of the energy band gap of the AgGaS₂ obtained from the absorption spectra was well described by the Varshni's relation, E/sub g/(T) = 2.7284 eV - (8.695×10/sup -4/ eV/K)T²/(T + 332 K). After the as-grown AgGaS₂ single crystal thin films was annealed in Ag-, S-, and Ga-atmospheres, the origin of point defects of AgGaS₂ single crystal thin films has been investigated by the photoluminescence (PL) at 10 K. The native defects of V/sub Ag/, V/sub s/, Ag/sub int/, and S/sub int/ obtained by PL measurements were classified as a donors or accepters type. And we concluded that the heat-treatment in the Ag-atmosphere converted AgGaS₂ single crystal thin films to an optical n-type. Also, we confirmed that Ga in AgGaS₂/GaAs crystal thin films did not form the native defects because Ga in AgGaS₂ single crystal thin films existed in the form of stable bonds.

Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking (시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성)

  • Choi, Jin-Kyung;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

Design of a Waveguide Band-Pass Filter Using a Modified H-type Resonant Iris (변형된 H-형 공진 아이리스를 이용한 도파관 대역통과 여파기 설계)

  • Park, Kyoung-Je;Choi, Tae-Ho;Lee, Jong-Ig;Kim, Byung-Mun;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.347-353
    • /
    • 2018
  • In this paper, we studied a design method for a band-pass waveguide filter with a modified H-type resonant iris (RI) placed in a thin transverse wall of a rectangular waveguide. The horizontal straight gap at the center of a conventional H-shaped iris is modified to a U-shaped one to increase the equivalent capacitance, and the equivalent inductance is improved by changing the vertical two straight slots into C-shaped ones. From some simulation results for the frequency response of the proposed RI, it was observed that the proposed iris was advantageous for reducing its size and having better cutoff, compared to typical H-shaped one. Equivalent inductance, capacitance, and quality factor of the proposed RI were extracted to analyze its performance. A third-order band pass filter using the proposed modified H-shaped iris was designed and, it was observed that the filter operated in the frequency range of 9.18-9.84 GHz with its insertion loss of 0.3 dB and return loss of 14 dB.

Mesenchymal Smad4 mediated signaling is essential for palate development (구개 형성과정에서 간엽 내 Smad4 매개 신호전달의 역할)

  • Yoon, Chi-Young;Baek, Jin-A;Cho, Eui-Sic;Ko, Seung-O
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.6
    • /
    • pp.460-465
    • /
    • 2010
  • Introduction: A cleft palate is a common birth defect in humans with an incidence of 1/500 to 1/1,000 births. It appears to be caused by multiple genetic and environmental factors during palatogenesis. Many molecules are involved in palate formation but the biological mechanisms underlying the normal palate formation and cleft palate are unclear. Accumulating evidence suggests that transforming growth factor $\beta$/bone morphogenetic proteins (TGF-$\beta$/BMP) family members mediate the epithelial-mesenchymal interactions during palate formation. However, their roles in palatal morphogenesis are not completely understood. Materials and Methods: To understand the roles of TGF-$\beta$/BMP signaling in vivo during palatogenesis, mice with a palatal mesenchyme- specific deletion of Smad4, a key intracellular mediator of TGF-$\beta$/BMP signaling, were generated and analyzed using the Osr2Ires-Cre mice. Results: The mutant mice were alive at the time of birth with open eyelids and complete cleft palate but died within 24 hours after birth. In skeletal preparation, the horizontal processes of the palatine bones in mutants were not formed and resulted in a complete cleft palate. At E13.5, the palatal shelves of the mutants were growing as normally as those of theirwild type littermates. However, the palatal shelves of the mutants were not elevated at E14.5 in contrast to the elevated palatal shelves of the wild type mice. At E15.5, the palatal shelves of the mutants were elevated over the tongue but did not come in contact with each other, resulting in a cleft palate. Conclusion: These results suggest that mesenchymal Smad4 mediated signaling is essential for the growth of palatal processes and suggests that TGF-$\beta$/BMP family members are essential regulators during palate development.

Differences in percussion-type measurements of implant stability according to height of healing abutments and measurement angle (임플란트 healing abutment 높이와 타진각도에 따른 타진방식 임플란트 안정성 측정기기의 수치 차이)

  • Park, Yang-Hoon;Leesungbok, Richard;Lee, Suk-Won;Paek, Janghyun;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.278-286
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the effect of healing abutment height and measurement angle on implant stability when using Periotest and AnyCheck. Materials and methods: 60 implants were placed into artificial bone blocks. After implant insertion, 2, 3, 4 and 5 mm healing abutments were installed on 15 specimens, respectively. Insertion torque value, implant stability test, Periotest value were measured. Insertion torque value was controlled between 45 - 55 Ncm. AnyCheck was used for measuring implant stability test and Periotest M was used for measuring Periotest value. Implant stability test and Periotest value were measured at the angles of 0 and 30 degrees to the horizontal plane. Measured values were analyzed statistically. Results: Insertion torque value had no significant difference among groups. When healing abutment height was higher, implant stability test and Periotest value showed lower stability. Also when measurement angle was decreased, implant stability test and Periotest value showed lower stability. Conclusion: When measuring stability of implants with percussion type devices, measured values should be evaluated considering height of healing abutments and measurement angle.

SHORT-TERM EFFECTS OF THE FUNCTIONAL REGULATOR III APPLIED TO ANTERIOR CROSSBITE PATIENTS IN EARLY MIXED DENTITION (기능성 반대교합을 가진 초기 혼합치열기 어린이에서 FR III를 단기간 장착했을 때의 효과)

  • Woo, Se-Eun;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.293-300
    • /
    • 2012
  • In case of treating the functional type of anterior cross bite, removing the cause in early stage prevents from turning to skeletal type, leads to perform normal function, and has improved facial appearance. Functional Regulator III (FR III), one kind of the Functional regulator(FR)s suggested by R$\ddot{o}$lf Fr$\ddot{a}$nkel in 1966, applied to patients with the functional and skeletal anterior crossbite in early mixed, and permanent dentition. This appliance improves unbalanced power condition by blocking abnormal muscle-power effect, so that normal growth can be expected. In this case report, favorable results were obtained by selecting clinical cases of children in their early mixed dentition with functional cross bite. 1. FR IIIs were applied to patients with anterior crossbite for 5~6 months. Anterior crossbite patients were corrected favorably, nevertheless they didn't show any horizontal skeletal-changes by buccal shields. 2. Normal occlusion and esthetic facial contour were achieved from dental movement of maxillary and mandibular anterior teeth while the mandible rotates to posterior and inferior direction.