• 제목/요약/키워드: Home Indoor Air Quality

검색결과 35건 처리시간 0.025초

실내공기질에 따른 재실자의 인식성 공기질 평가 (Perceived Air Quality Assessment of Occupants According to Indoor Air Quality)

  • 우병렬;이현수;안호기;정순원;황문영;박충희;유승도;양원호
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.61-69
    • /
    • 2011
  • Perceived air quality (PAQ) is defined as evaluation of indoor air satisfaction and comfortable sensory by occupants. However, there are differences between criteria of indoor pollutants and lowest sensory thresholds. In this study, we compared indoor PAQ by questionnaire with measured benzene, toluene and nitrogen dioxide ($NO_2$) concentrations in home indoors. The $NO_2$ concentration was the highest in Seoul, while benzene and toluene were the highest in Asan. Average PAQ score in winter was higher than that in summer. Significant correlations between PAQs of home indoor air pollution and measured pollutant concentrations were not shown and correlation coefficients (r) ranged between -0.453

주거 건물의 설계 및 시공단계를 고려한 실내공기질 평가 프로그램 개발에 관한 연구 (Development of Home Indoor Air Quality evaluation program considering planning and construction stage)

  • 최동희;강동화;김선숙;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.51-56
    • /
    • 2005
  • The objective of this study is to develop Home Indoor Air Quality evaluation prorgram considering planning and construction stage for architects, engineers and occupants to estimate and improve the IAQ of a home. In this study, the IAQ modeling technique was discussed to determine the appropriate modeling of housing unit in Korea. The program algorithm was developed based on the selected model reflecting planning and construction stage. This program can be applied to estimate the IAQ of a home and encourage appropriate action in advance.

  • PDF

컬러TV 제품의 오염물질 방출특성 평가방법과 관리 기준안 설정에 대한 연구 (Evaluation Methods for Chemical Emissions from TV Products and Establishing Criteria for the Perceived Indoor Air Quality)

  • 강효석;윤동원;이윤규
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.304-313
    • /
    • 2010
  • During recent years, various studies have demonstrated that indoor chemical pollution causes health problem and also negatively affect the performance of work by occupants. Building materials have been concerned as indoor chemical sources. Some of guidelines and certification system has been developed and resulted as dramatic decrease of harmful indoor chemicals such as formaldehyde and volatile organic compounds. Also, Home furniture and electrical devices has been concerned as one the primary influence the indoor chemical concentration in residential spaces. It is found that various kinds of electric home appliances have a significant source of chemical emission in indoor environments. In this study, the methodologies of detecting harmful chemicals from various kinds of products has been developed with large chamber measurement system and suggest some of the evaluation method for the chemicals from the home appliances as TV sets.

여름철 가정집에서의 산성오염물질에 대한 실내 공기질 특성 (Characteristics of Indoor Air Quality of Acidic Air Pollutants in a Private Home During Home During the Summer Season)

  • 이학성;강병욱;강충민;여현구
    • 한국대기환경학회지
    • /
    • 제17권2호
    • /
    • pp.193-201
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality in a residential area in the summer. All indoor and outdoor samples were measured simultaneously using an annular denuder system(ADS) in Seoul. The data set was collected from July 26 to September 11, 1997. The mean indoor/outdoor ratios measured from this study were : 0.34 for $HNO_3$; 0.91 for $HNO_2$; 0.22 for $SO_2$; 1.34 for $NH_3$; 0.78 for $PM_{2.5}(d_p$ <2.5 $mutextrm{m}$); 0.90 for $SO_{4}^{2-}$; 0.68 for $NO_{3}^{-}$ and 0.79 for $NH_{4}^{+}$. Indoor concentrations of $HNO_3$, $SO_2$ and $PM_{2.5}$ were highly correlated with the outdoor concentrations. The relationship between indoor and outdoor air is dependent, to a large extent, on the rate of air exchange between these two environments. A tracer-gas decay technique with sulfur hexafluoride ($SF_{6}$) as a tracer gas was used to estimate the air exchange of a private home in the summer. The average air exchange rate was estimated to be 23.7 hr(sup)-1. The deposition velocities for $SO_{4}^{2-}$, $NO_{3}^{-}$ and $NH_{4}^{+}$ calculated were 0.17, 0.69 abd 0.39 cm/sec, respectively.

  • PDF

온도 및 습도 조건에 따른 침실 공기환경에 관한 연구 (A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions)

  • 김동규;김세환
    • KIEAE Journal
    • /
    • 제11권3호
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

공동주택의 겨울철 실내공기환경에 대한 거주자 반응 (Resident's Subjective Responses to Indoor Air quality of Multi Family Houses in Winter)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제35권2호
    • /
    • pp.173-186
    • /
    • 1997
  • The purpose of this study is to find out understand the resident's subjective responses to physical indoor environment. The questionnaire survey was carried out to measure form Jan. 8th to Feb. 2th in 1996, the typical external climate of winter in Korea. The subjects were four hundred and eleven housewives, living in apartments of RC structure I Ilsan apartment complex. As the result, residents usual ventilate once or twice a day by opening outward windows for about ten minutes. Unpleasant smell producted by cooking and wet garbage made most of them negatively respond to kitchen's air quality. regression analysis of relativeness between sense of air freshness smell, dust and comfort revealed that sense of comfort was the most highly related with the extent of bad smell. Housing factors such as size of apartments and ventilating, smoking and gas usage had significant effects on indoor air quality and the subjective responses in winter. Therefore it is especially important to consider air pollution problem from the beginning stage when planning small apartments. It is required that the government of environment has to emphasize the importance of ventilation to residents, and makes an effort to establish the design criteria on indoor air quality in house.

  • PDF

유치원 여교사(女敎師)와 전업주부(主婦)의 이산화질소 노출비교 및 평가 (Comparative Study on Nitrogen Dioxide Exposure of Female Teachers from Kindergarten and House Wives)

  • 양원호;김순복;배현주;이영미;정문호;정문식
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2001
  • Since most people spend over 80% of their time indoor, indoor air quality tends to be the dominant contributor to personal exposure. In this study, indoor and outdoor $NO_2$concentrations were measured and compared with simultaneously personal exposures of 27 house-wives and female workers of kindergarten. Time activity pattern and house characteristics were used to determine the effects of these factors on personal exposure. Since house-wives student spent most their times in indoor with mean of 89.8%, their $NO_2$ exposure was associated with indoor $NO_2$ level(r= 0.92) rather than outdoor $NO_2$ level(r= 0.87). female workers were also associated with indoor $NO_2$ level(r= 0.70) though sample number were small. Using time-weighted average model, $NO_2$ exposures of house-wives were estimated by $NO_2$ measurements in indoor home and outdoor home levels. Estimated $NO_2$ personal exposures were significantly correlated with measured $NO_2$ personal exposures (r= 0.90). These results might mean that air pollutants exposure of old and feeble persons, and infants could be estimated by measuring concentrations of indoor home.

  • PDF

유아교육시설 내 실내공기유해오염물질에 대한 어린이 건강위해성평가 (Childrens' Health Risk Assessment on Indoor Hazardous Air Pollutants of Preschool Facility)

  • 고연정;김신도;박숙영;장성기
    • 한국환경보건학회지
    • /
    • 제35권2호
    • /
    • pp.78-85
    • /
    • 2009
  • In this study, the hazard rate of the indoor environment of Children's Educational Facilities in Seoul was conducted, in order to determine how the indoor environments of these facilities, where infants and children spend the most time of their away from home day, can effect their health. The way of measurement and analysis were done according to the Indoor Air Quality Standard Method, and the Risk Assessment was accomplished with several significant ways - Hazard Identification, Exposure Assessment, Dose-response Assessment, Risk Characterization, which are deighed by National Research Council (NRC). On each exposure factors, documentary and questionary research such as Epidemiological study and Toxicological study were conducted. The result of the CTE (Central tendency exposure) of Formaldehyde and Benzene by Monte-Carlo simulation was $6.79{\times}10^{-6}$, $2.50{\times}10^{-7}$ which in the case of Formaldehyde exceeded the permitted standard ($10^{-6}$) of the US EPA. The RME(Reasonable maximum exposure) was $7.31{\times}10^{-5}$, $2.65{\times}10^{-6}$ which did not exceed $10^{-4}$, the maximum permitted standards in the US EPA.

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • 한국환경과학회지
    • /
    • 제18권5호
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.