Characteristics of Indoor Air Quality of Acidic Air Pollutants in a Private Home During Home During the Summer Season

여름철 가정집에서의 산성오염물질에 대한 실내 공기질 특성

  • Published : 2001.02.01

Abstract

Acidic air pollutants were collected to characterize indoor air quality in a residential area in the summer. All indoor and outdoor samples were measured simultaneously using an annular denuder system(ADS) in Seoul. The data set was collected from July 26 to September 11, 1997. The mean indoor/outdoor ratios measured from this study were : 0.34 for $HNO_3$; 0.91 for $HNO_2$; 0.22 for $SO_2$; 1.34 for $NH_3$; 0.78 for $PM_{2.5}(d_p$ <2.5 $mutextrm{m}$); 0.90 for $SO_{4}^{2-}$; 0.68 for $NO_{3}^{-}$ and 0.79 for $NH_{4}^{+}$. Indoor concentrations of $HNO_3$, $SO_2$ and $PM_{2.5}$ were highly correlated with the outdoor concentrations. The relationship between indoor and outdoor air is dependent, to a large extent, on the rate of air exchange between these two environments. A tracer-gas decay technique with sulfur hexafluoride ($SF_{6}$) as a tracer gas was used to estimate the air exchange of a private home in the summer. The average air exchange rate was estimated to be 23.7 hr(sup)-1. The deposition velocities for $SO_{4}^{2-}$, $NO_{3}^{-}$ and $NH_{4}^{+}$ calculated were 0.17, 0.69 abd 0.39 cm/sec, respectively.

Keywords

References

  1. 한국대기보전학회지 v.13 no.5 청주지역 산성 가스상물질과 미세입자의 계절 변동 특성 강병욱;이학성;김희강
  2. 한국대기보전학회지 v.12 no.4 디누더 측정기를 이용한 여름철 청주시의 산성오염물질 측정과 분석 이학성;강병욱
  3. 한국대기환경학회지 v.15 no.2 서울지역 여름철과 겨울철 산성 오염물질의 농도 특성에 대한 연구 이학성;강충민;강병욱;김희강
  4. 한국대기보전학회지 v.13 no.5 Annular denuder system을 이용한 부산시 대기중 산성오염물질의 특성 정장표;정창용;이학성
  5. Environ. Health Perspect. v.103 no.5 Measurement of acidic aerosol species in Eastern Europe: Implications for air pollution epidemiology Brauer, M;T.S. Dumyahn;J.D. Spengler;K. Gutschmidt;J. Heinrich;H.E. Wichmann
  6. J. Air Waste Manage. Assoc. v.41 Indoor and outdoor concentrations of inorganic acidic aerosols and gases Brauer, M;P. Koutrakis;G.J. Keeler;J.D. Spengler
  7. Environ. Sci. Technol. v.24 Measurements of nitrous acid inside two research houses Brauer, M;B. Ryan;H.H. Suh;P. Koutrakis;J.D. Spengler
  8. Environ. Health Perspect. v.104 no.5 Health effects of acid aerosols in North American children : Respiratory symptoms Dockery, D.W.;J. Cunningham;A.I. Damokosh;L.M. Neas;J.D. Spengler;P. Koutrakis;J.H. Ware;M. Raizenne;F.E. Speizer
  9. Atmos. Environ. v.15 Indoor-outdoor relationships of respirable sulfates and particles Dockery, D.W;J.D. Spengler
  10. Atmos. Environ. v.25A Prediction and experimental evidence for high air concentration of nitrous acid in indoor environments Febo, A;C. Perrino
  11. Environ. Sci. Technol. v.32 Detection of excess ammonia emissions from in-use vehicles and the implications for fine particle control Fraser, M.P;G.R. Cass
  12. Atmos. Environ. v.22 Laboratory studies of the kinetics of formation of nitrous acid from the thermal reaction of nitrogen dioxide and water vapor Jenkin, M.E;R.A. Cox;D.J. Williams
  13. Atmos. Environ. v.26A Nitrous ans nitric acid measurements at sites in south-east England Ktto, A.N;R.M. Harrison
  14. Environ. Sci. Technol. v.26 no.3 Source apportionment of indoor aerosols in Suffolk and Onondaga counties Koutrakis, P;S.L. Briggs;B.P. Leaderer
  15. Environ. Sci. Technol. v.22 no.12 Evaluation of an annular denuder/filter pack system to collect acidic aerosols and gases Koutrakis, P;J.M. Wolfson;J.L. Slater;M. Brauer;J.D. Spengler;R.K. Stevens;C.L.Stone
  16. J. Korean Air Pollut. Research Assoc. v.9 no.E Evaluation of impact of tobacco smoke on indoor air quality Lee, H.S.;R.A. O'brien
  17. Atmos. Environ. v.27A Measurement and evaluation of acid air pollutants in Chicago using an annular denuder system Lee, H.S.;R.A. Wadden;P.A. Scheff
  18. Atmos. Environ. v.31 no.11 Relationships between indoor and outdoor air quality during the summer season in Korea Lee, H.S.;B.-W. Kang;J.-P. Cheong;S.-K. Lee
  19. Atmos. Environ. v.33 no.19 Seasonal variations of acidic air pollutants in Seoul, South Korea Lee, H.S.;C.-M. Kang;H.-K. Kim
  20. J. Air Waste Manage. Assoc. v.49 Ozone decay rates in residences Lee, K.Y.;J. Vallarino;T, Dumyahn;H, Ozkaynak;J.D. Spengler
  21. Atmos. Environ. v.27A Relationships between indoor and outdoor air quality in four naturally ventilated office in the United Kingdom Phillips, J. L.;R. Field;M. Goldstone;G.L. Reynolds;J.N. Lester;R. Perry
  22. Atmos. Environ. v.17 no.12 New design of a high-performance denuder for the sampling of atmospheric pollutants Possanzini, M;A. Febo;A. Liberti
  23. Environ. Sci. Technol. v.29 no.8 Weighing the health risks of airborne particulates Reichhardt, T.
  24. Environ. Sci. Technol. v.24 no.7 Nitric acid concentrations in Southern California Museums Salmon, L.G.;W.W. Nazaroff;M.P. Ligocki;M.C. Jones;G.R. Cass
  25. Atmospheric Chemistry and physics of air pollution Seinfeld, J.H.
  26. Final report, Ny State ERDA Contract no.736-Con-BCS-85 An investigation of infiltration and indoor air quality Sheldon, L.S.;T.D. Hartwell;B.G. Cox;J.E. Sickles II;E.D. Pellizzari;M.L. Smith;R.L. Perritt;S.M. Jones
  27. Atmos. Environ. v.30 no.6 Laboratory and field evaluation of an improved glass honeycomb denuder/filter pack sampler Sioutas, C.;P.Y. Wang;S.T. Ferguson;P. Koutrakis
  28. Environ. Sci. Technol. v.27 Nitrous acid in Albuquerque , New Mexico, Homes Spengler, J.D.;M. Brauer;J.M. Samet;W.E. Lambert
  29. Environ. Sci. Technol. v.24 no.7 Acid air and health Spengler, J.D.;M. Brauer;P. Koutrakis
  30. Atmos. Environ. v.16 Relative humidity and temperature dependence of the ammonium nitrate dissociation constant Stelson, A.W.;J.H. Seinfeld
  31. J. Air Waste Manage. Assoc. v.45 Spatial variation in acidic sulfate and ammonia concentrations within metropolitan Philadelphia Suh, H.H.;G.A. Allen;P. Koutrakis;R.M. Burton
  32. Atmos. Environ. v.28 no.18 Field method comparison for the characterization of acid aerosols and gases Suh, H.H.;G.A. Allen;B.A. Blajeni;P. Koutrakis
  33. Indoor air pollution Wadden, R.A.;P.A. Scheff
  34. Atmos. Environ. v.31 no.21 Potential reactions among indoor Pollutants Weschler, C.J.;H.C. Shields
  35. Environ. Sci. Technol. v.26 no.1 Indoor ozone and nitrogen dioxide: A potential pathway to the generation of nitrate radicals, dinitrogen pentaoxide and nitric acid indoors Weschler, C.J.;M. Brauer;P. Koutrakis P.
  36. J. Air Pollut. Contol Assoc. v.36 Indoor ozone exposures Weschler, C.J.;D.V. Naik;H.C. Shields