• 제목/요약/키워드: High-temperature design

검색결과 2,764건 처리시간 0.03초

높은 전력밀도를 갖는 500 kHz 고주파 LLC 컨버터의 설계와 구현 (Design and Implementation of 500 kHz High Frequency LLC Resonant Converter for High Power Density)

  • 박화평;정지훈
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.51-58
    • /
    • 2015
  • In order to decrease the size of a switch mode power supply, high switching frequency can be an efficient way to reduce the size of passive components in the converter. In this paper, a 500-kHz high-frequency LLC resonant converter is proposed with an accurate design method of magnetizing inductance, as well as the relationship between the switching frequency and the size of the passive components. Simulation and experimental results are presented to verify the proposed methods and equations, including the temperature data of each passive and active device of the converter. Using those results, dominant power losses in the prototype converter under 500-kHz high-frequency operation are investigated, compared with the results from a 100-kHz converter. In addition, operating waveforms and power conversion efficiency will be shown to obtain design considerations for the high switching frequency LLC resonant converter.

APR1400 IRWST Pool 온도분포 해석 (A Numerical Study on the IRWST Pool Temperature Distributionin in APR1400)

  • 강형석;배윤영;박종균
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.813-820
    • /
    • 2001
  • The Safety depressurization System(SDS) of KNGR prevents RCS from overpressurization by discharging high pressure and temperature coolant through the I-sparger into the IRWST during an accident. If IRWST water temperature rise locally, around the sparger, beyond $200_{\circ}$2000 F by the discharged coolant, unstable steam condensation can cause large pressure load on the IRWST wall. To investigate whether this condition can be avoided for the design basis event IOPOSRV(Inadvertent Opening of one Pilot Operated Safety Relief Valve), the flow and temperature distribution of water in the IRWST is calculated by using CFX 4.3 computational fluid dynamic code. According to the results, since pool water temperature does not exceeds temperature limit within 50 seconds after the opening of one POSRV, it can be assured that the integrity of IRWST wall is maintained.

  • PDF

A novel hydrogel-dispersed composite membrane of poly(N-isopropylacrylamide) in gelatin matrix and its thermally actuated permeation of 4-acetamidophen

  • Chun, Suk-Won;Kim, Jong-Duk
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 춘계 총회 및 학술발표회
    • /
    • pp.50-51
    • /
    • 1995
  • The swelling behavior of hyddrogels has been interested in many applications of drug carriers. These gels show reversible swelling changes in response to pH, electric currcnt, and temperature. Among others, the temperature-responsive behavior of poly(N-isopropylacrylanxide) (p(NIPAAm)) was studied, because a lower critical solution temperature(LCST) is in the vicinity of 32$\circ$C, and remarkable temperature-response can be obtained. We propose a novel composite membrane, which is appropriate for transporting drug ingredients above the transition temperature. Our object was to design a high permeation system above the shrinking temperature of p(NIPAAm). The membrane was composed of a matrix polymer and thermosensitive p(NIPAAm) hydrogel. The flux pattern of 4-acctamidophen through membrane in response of temperature was opposite to that of p(NIPAAm) membrane.

  • PDF

일중/이중효용 하이브리드 타입 흡수식 냉동기 성능 특성에 관한 수치적 연구 (Performance analysis for the Characteristics of Double/ Single Effect Hybrid type Absorption Chiller)

  • 유다영;송태민;이정병;김형진;임익태;문상돈;박찬우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.272-278
    • /
    • 2009
  • The characteristics of hybrid type absorption chiller are studied numerically to use a waste hot water effectively. In the case of the full load, the concentration and temperature of LiBr solution are increase about $11^{\circ}C$, 1.3% respectively at the single effect generator by hot water. As a result, the heat of the high temperature generator are decrease, so the energy can be saved. As the partial load decreased the consumption ratio of fuels are decreased and the reduction ratio of fuels are increased. The variation of COP with the inlet temperature of hot water is higher than that of the flow rate of hot water. The effect of mean temperature difference with solution and hot water of the generator are higher that of flow rate of hot water, it can effect on COP which is sensitive to heat of generator.

  • PDF

시판 부직포의 물성에 관한 연구 (A study on the properties of commercial nonwoven fabrics)

  • 송화순
    • 한국의류학회지
    • /
    • 제11권1호
    • /
    • pp.79-85
    • /
    • 1987
  • The purpose of this study was to help the consumer about the care of nonwoven fabrics by investigation of the properties such as launderability. shrinkage, color fastness and strenth. Materials used were two types, soft and stiff, of commercial nonwoven fabrics. Deter-gents used were neutral detergents, synthetic detergents and dry cleaning solutions(perch-toro-ethylene) The results of this study were summerized as follows; 1. Laundering of nonwoven fabrics in low temperature is more ideal as morphological changes by laundering in high temperature were more prominent than that in low temperature. 2. Ironing of nonwoven fabrics wants more attention on environmental temperature as the rate of shrinkage in high temperature was higher than that in low temperature. Neutral detergents are more desirable as the rate of shrinkage of nonwoven fabrics by laundering with synthetic detergents was more prominent than that with neutral deter-gents. The rate of shringkage of nonwoven fabrics was not affected by dry cleanining. 3. Special care is wanted in order to prevent color transfer from non woven fabrics to polyester or wool during dry cleaning or laundering as the color fastness test show that color changes of nonwoven fabrics were not affected, but that color stain was increased on polyester or wool. 4. The strength was affected by composition of fibers and types of nonwoven fabrics, soft or stiff.

  • PDF

KIST와 FZ-Julich SOFC간의 출력성능 비교 (Comparison of the Power Generating Characteristics of KIST- and FZ-Julich SOFCs)

  • 정화영;이상철;;김혜령;이해원;이종호
    • 한국세라믹학회지
    • /
    • 제44권12호
    • /
    • pp.703-709
    • /
    • 2007
  • We evaluate and compare the power generating characteristics of the anode supported SOFCs which have been fabricated from KIST and FZ-Julich in Germany. The performance and electrochemical property of each unit cell was characterized at the temperature range of $650-850^{\circ}C$ under same operating conditions and its microstructural property was thoroughly investigated via SEM after the performance test. According to the investigation, KIST- and FZJ SOFC showed different power generating characteristics in their temperature dependances due to their different design of electrode microstructure, especially the cathode microstructure. FZJ SOFC showed better performance at high temperature while showed lower performance at lower temperature. From the investigation about the correlation between microstructure and electrochemical property, we found that the superior performance of FZJ SOFC at high temperature was mainly due to its lower cathodic polarization resistance whereas better performance of KIST SOFC at lower temperature was mostly attributed to the lower ohmic resistance.

열하중하에서 핵연료조사캡슐에 대한 최적화 (Optimization for the Nuclear Fuel Irradiation Capsule under Thermal Loading)

  • 최영진;이영신;강영환;이종웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.564-569
    • /
    • 2003
  • During fuel irradiation tests, all parts of cylindrical structure with multiple holes act as heat sources due to fussion heal and ${\gamma}-flux$. The high temperature is especially generated over $2500^{\circ}C$ in the center of pellet. Due to the high temperature, many problems occur, such as melting of pellet and declining of heat transfer between cladding and coolant. [n this study, it is attempted 10 minimize the temperature of pellet using optimization method about geometric variables. For thermal and optimization analysis or structure. the finite element method code. ANSYS 5.7 is used. In this procedure. subproblem approximation method is used to the optimization methods. Through the optimum design process, the temperature of sealed basket type is reduced from $2537^{\circ}C$ to $2181^{\circ}C$ and the temperature of open basket type is reduced from $2560^{\circ}C$ to $2106^{\circ}C$.

  • PDF

저 NOx 희박연소기의 주연소영역에서의 연소특성 연구 (The Combustion Characteristics at Primary Zone of Lean Premixed low NOx Combustor)

  • 임암호;안국영;김한석;김용모
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.314-319
    • /
    • 2003
  • The concept of lean-premixed combustion in gas turbine combustor operation has become a standard in recent years as an effective means to meet stringent enviromental standards on NOx emissions. The combustion characteristics of 75 kW class lean premixed combustor were investigated at the conditions of high temperature and ambient pressure. The exit temperature and emissions of CO and NOx were measured at the center of exit plane. The high temperature air of $550K{\sim}650K$ was supplied through air preheater. As expected, experimental results indicate that NOx emission was increased and CO emission was decreased by increasing inlet air temperature. But CO emission measured at the center of exit plane was increased because of the non-uniform radial direction profiles. The Semi-Empirical Correlation method was applied to obtain the design point emissions of NOx and CO. Also the flame temperature, CO and NOx emissions were measured along the centerline of liner at 650K inlet air temperature to determine the position of dilution holes.

  • PDF

Design and Implementation of Wireless Sensor Network for Freeze Dryer

  • Cho, Young Seek;Kwon, Jaerock;Choi, Seyeong
    • Journal of information and communication convergence engineering
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2015
  • A wireless sensor network (WSN) is designed and implemented for a freeze dryer. Freeze-drying technology is widely used in the fields of pharmacy and biotechnology as well as the food and agriculture industries. Taking into account the demand for high-resolution pressure and temperature measurements in a freeze dryer, the proposed WSN has a significant advantage of creating a monitoring environment in a freeze dryer. The proposed WSN uses a ZigBee/IEEE 802.15.4 network with an altimeter module that contains a high-resolution pressure and temperature sensor with a serial digital data interface. The ZigBee network is suitable for low-energy and low-data-rate applications in the field of wireless communication. The altimeter module is capable of sensing pressure in the range of 7.5-975 Torr (10-1300 mbar) and temperature in the range of $-40^{\circ}C$ to $125^{\circ}C$ with a DC power consumption of $3{\mu}W$. The implemented WSN is installed in a commercial laboratory freeze dryer in order to demonstrate its functionality and efficiency. A comparison with the temperature profile measured by a thermocouple installed in the freeze dryer reveals that the resolution of the temperature profile measured by WSN is superior to that measured by the thermocouple.

고탄소 연구강의 잠입귀열 방지에 관한 연구 (Study on Prevention of Quench Crack in Martensitic High Carbon Tool Steel)

  • 김학신;방성한;최종술;영형영
    • 한국표면공학회지
    • /
    • 제14권3호
    • /
    • pp.142-150
    • /
    • 1981
  • The present paper clarified mechanism of quench crack formation in high carbon steel dur-ing quenching, and, in order to prevent the quench crack, proposed two basic guides in alloy design of high carbon tool steel. They are to raise Ms temperature of high carbon tool steel by addition of alloying elemen-ts such as Al and Co, and to decrease grain size of the carbon tool steel by addition of alloying elements of Al, B, Ti, Zr, and V, and by grain-refining heat treatment.

  • PDF