• 제목/요약/키워드: High-temperature cable

검색결과 301건 처리시간 0.028초

초전도케이블 시장진입 가격 산정 방법론 고찰 (Methodology for Estimating the HTS Cable Market Price)

  • 김종율;이승렬;윤재영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권10호
    • /
    • pp.536-541
    • /
    • 2004
  • As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable has the several useful characteristics such as increased power density, stronger magnetic fields and/or reduced losses. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In these days, companies world-wide have conducted researches on HTS cable. A development project for a 22.9kV class HTS cable is proceeding at a research center and university in Korea. In this paper, we investigate the expected price of HTS cable to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional cable is calculated and based on this, the expected price of HTS cable is evaluated, which HTS cable is competitive against conventional cable.

차폐층을 고려한 고온초전도 전력 케이블의 전류분류 해석 (Analysis of Current Distribution of HTSC Power Cable Considering Shield Layer)

  • 이종화;임성훈;고석철;박충렬;한병성;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.12-14
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of import ant parameters in high-temperature superconduting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and AC loss. In this paper, the transport current distribution at conducting layers was investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer and compared with the case of without shield layer. The transport current distribution due to of the contact resistance and the pitch was improved in the case of HTSC power cable with shield layer from the analysis.

  • PDF

피치길이와 결선방향에 따른 다층 고온초전도 전력케이블의 전류분류 분석 (Analysis of Current Distribution of Multi-Layer HTSC Power Cable dut to Pitch length and winding direction)

  • 이종화;임성훈;고석철;박충렬;한병성;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1133-1135
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of important parameters in high-temperature superconducting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and ac loss. In this paper, the transport current and magnetic field distributions at conducting layers were investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer. The transport current distribution due to the pitch length and winding direction was improved in case of HTSC power cable with shield layer.

  • PDF

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Life-cycle 비용 산정을 통한 초전도케이블 경제성 검토 (A Economic feasibility of HTS cable by estimating the Life-Cycle cost)

  • 김종율;이승렬;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.424-426
    • /
    • 2004
  • As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable has the several useful characteristics such as increased power density, stronger fields and/or reduced losses. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In these days, companies world-wide have conducted researches on HTS cable. A development project for a 22.9kV class HTS cable is proceeding at a research center and university in Korea. In this paper, we investigate the expected price of HTS cable to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional cable is calculated and based on this, the expected price of HTS cable is evaluated, which HTS cable is competitive against conventional cable.

  • PDF

초전도 케이블의 Quench 특성에 대한 계통안전성 제어방식 (Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable)

  • 이근준;황시돌
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.29-35
    • /
    • 2005
  • 본 논문은 고온 초전도 케이블을 전력계통의 송전용량 증대를 위해 적용시켰을 경우, 고장발생시 초전도케이블에서 예상되는 ??????치의 영향에 대해 안전하게 제어할 수 있는 방법을 제시하였다. 접근 방법으로는 초전도케이블의 ??????치 특성을 열평형 방정식으로 모델링하고 그 결과 고장전류에 따른 케이블의 설계 최대 온도상승한계에 도달하는 시간을 산출하여 기존의 보호계전시스템의 차단시간과 비교함으로서 안전성 여부를 판정하였다. ??????치발생 고장시간을 모의하기 위해 초전도케이블용 EMTDC모형을 개발하였으며, 모의 결과 초전도 케이블 계통을 보호할 수 있는 안전성 제어방식이 설계 가능함을 보였다.

Parametric Study of AC Current Lead for the Termination of HTS Power Cable

  • Kim, D.L;Kim, S.H.;S. Cho;H.S. Yang;Kim, D.H.;H.S. Ryoo;K.C. Seong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.107-110
    • /
    • 2003
  • High Temperature Superconductor (HTS) transmission cable can carry more than 2 to 5 times higher electricity and also obtain substantially lower transmission losses than conventional cables. Liquid nitrogen is to be used to cool the HTS power cable and its cost is much cheaper than the liquid helium used for the cooling of metal superconducting wire. In Korea the HTS power cable development project has been ongoing since July, 2001 with the basic specifications of 22.9kV, 50MVA and told dielectric type as the first 3-year stage. The cryogenic system of the HTS cable is composed of HTS cable cryostat termination and refrigeration system. Termination of HTS cable is a connecting part between copper electrical cable at room temperature and HTS cable at liquid nitrogen temperature. In order to design the termination cryostat, it is required that the conduction heat leak and Joule heating on the current lead be reduced, the cryostat be insulated electrically and good vacuum insulation be maintained during long time operation. Heat loads calculations on the copper current lead have been performed by analytical and numerical method and the feasibility study fer the other candidate materials has also been executed.

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.

LGT를 이용한 고온, 고압용 동압 센서 개발 (Development of the high-temperature, high-pressure Dynamic pressure sensor with LGT)

  • 권혁제;이경일;김동수;김영덕;이영태
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.17-21
    • /
    • 2012
  • This study developed a high-temperature, high-pressure dynamic pressure sensor using LGT(lanthanum gallium tantalate). The sensitivity of the fabricated dynamic pressure sensor was 2.1 mV/kPa and its nonlinearity was 2.5%FS. We confirmed that the high-temperature dynamic pressure sensor operated stably in high-temperature environment at $500^{\circ}C$. The developed dynamic pressure sensor using LGT is expected to be applicable not only to gas turbines but also in various industrial areas in duding airplanes and power stations.

PSCAD/EMTDC를 이용한 3 상 다층 고온 초전도 케이블의 모델링 및 과도 해석 (Modelling and Transient Analysis of a 3-Phase Multi-Layer HTS Coaxial Cable using PSCAD/EMTDC)

  • 이준엽;이석주;박민원
    • 한국산업정보학회논문지
    • /
    • 제25권1호
    • /
    • pp.25-30
    • /
    • 2020
  • 3상 다층 고온 초전도 동축 케이블은 초전도 선재 사용량의 감소 및 케이블의 소형화와 같은 이점 때문에 활발히 연구되고 있다. 3상 다층 고온 초전도 동축 케이블의 전기적 특성은 기존 초전도 케이블과 차이를 가지므로 실제 시스템에 적용하기 위해 충분한 분석이 필요하다. 본 논문에서는 PSCAD/EMTDC 기반 시뮬레이션을 통하여 22.9 kV, 60 MVA급 3상 다층 고온 초전도 동축 케이블을 모델링하고 과도 특성을 분석하였다. 결과적으로 3상 다층 고온 초전도 동축 케이블에서 고장전류가 발생하면 대부분의 고장전류가 구리 포머층을 통해 우회한다. 이때, 케이블 전체 온도는 약 5 K 증가하였다. 본 논문을 통해 3상 다층 고온 초전도 동축 케이블의 과도 상태에 대한 신뢰성을 확인할 수 있으며 향후 케이블의 실 계통 적용에 도움이 될 수 있다.