• 제목/요약/키워드: High-pressure Leak

검색결과 106건 처리시간 0.021초

동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구 (Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure)

  • 권영희;황동환;김태길;강경식
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.

기어펌프.모터 이끝 틈새의 영향에 관한 연구 (A Study on the Effect of Gear Teeth End-Gaps for Hydraulic Gear Pumps and Motors)

  • 정헌술;풍려려;오석형
    • 유공압시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.23-29
    • /
    • 2005
  • In order to improve the efficiency of hydraulic gear pumps or motors especially for high operating pressure, power losses due to viscous friction and leak flow through gear teeth end-gaps are considered in this paper. Optimal gaps minimizing the power loss for pumps and motors with uniform heights of gaps are analysed first. And the effect of the shapes of gaps with unequal heights on the power loss are studied and discussed by simulation. Considering that the outer shell lacing gear teeth may expand due to high internal pressure or thermal stress, the results drawn in this paper can be used for the design of high efficiency pumps and motors.

  • PDF

Modeling of non-isothermal CO2 particle leaked from pressurized source: I. Behavior of single bubble

  • Chang, Daejun;Han, Sang Heon;Yang, Kyung-Won
    • Ocean Systems Engineering
    • /
    • 제2권1호
    • /
    • pp.17-31
    • /
    • 2012
  • This study investigated the behavior of a non-isothermal $CO_2$ bubble formed through a leak process from a high-pressure source in a deep sea. Isenthalpic interpretation was employed to predict the state of the bubble just after the leak. Three modes of mass loss from the rising bubble were demonstrated: dissolution induced by mass transfer, condensation by heat transfer and phase separation by pressure decrease. A graphical interpretation of the last mode was provided in the pressure-enthalpy diagram. A threshold pressure (17.12 bar) was identified below which the last mode was no longer present. The second mode was as effective as the first for a bubble formed in deep water, leading to faster mass loss. To the contrary, only the first mode was active for a bubble formed in a shallow region. The third mode was insignificant for all cases.

상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발 (Development of leakage test facility for leak signal characteristic analysis in water pipeline)

  • 박상혁;곽필재;이현동;최창호
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

고온 연소가스를 이용한 고공 환경 모사용 디퓨저 실험장치 연구 (An Experimental Study of a Diffuser Test Rig for Simulating High-Altitude Environment by using Hot)

  • 양재준;이양석;김유;고영성;김용욱;김춘택
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.31-34
    • /
    • 2007
  • 본 연구는 고온의 연소 가스를 이용하여 고공 환경 모사용 초음속 디퓨저의 성능을 파악하는 것이다. 실험 장치는 크게 액체로켓 연소실, 진공 챔버, 냉각수 링 및 디퓨저로 구성되어 있다. 먼저 연소실험 전에 고압의 질소가스(30barg)와 진공 펌프를 이용하여 액체로켓 엔진과 디퓨저의 기밀시험을 수행 하였다. 제작된 디퓨저를 포함한 시험 리그의 기밀테스트 결과, 고압 조건 및 진공압 조건에서 모두 누설이 없이 양호하였다.

  • PDF

음향방출기법을 이용한 원전 고온 고압 배관의 누설 특성 평가에 관한 연구 (A Study on the Leakage Characteristic Evaluation of High Temperature and Pressure Pipeline at Nuclear Power Plants Using the Acoustic Emission Technique)

  • 김영훈;김진현;송봉민;이준현;조윤호
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.466-472
    • /
    • 2009
  • 고온, 고압의 원자력 배관 누설 판별을 위해 음향방출기법(AE)을 이용한 누설감지 시스템인 ALMS 기법이 적용되고 있다. 이 시스템은 단지 AE 센서로 전해진 신호의 RMS값을 이용하여 누설의 유무만을 판단할 뿐, 누설 발생시 누설부의 크기나 형태를 평가하는 것에는 어려움이 있었다. 따라서 본 논문에서는 이러한 문제를 해결하기 위하여 AE센서와 가속도센서를 동시에 이용한 이중 센서 시스템을 제안하였다. 빠른 학습 속도와 정확성을 위해 Levenberg-Marquardt 학습 알고리즘을 이용한 인공신경회로망을 적용시키고, 이를 통해 신뢰성 있는 분석 결과를 얻을 수 있다. 배관내 압력과 누설부의 크기와 모양에 따른 실험신호들을 학습시키고 그 판별 정확성을 확인하였다. 추가적으로 배관 두께에 따라 발생하는 파(wave)의 종류와 특성이 달라지는 것을 이론과 실험을 통하여 알아보았다.

음향방출을 이용한 보일러튜브 누설평가 (Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2004
  • 발전소 보일러튜브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 크리프, 열피로와 같은 각종 열화에 의해 누설손상이 발생하고 있다. 이러한 누설손상을 실시간 감시하고 진단하기 위하여 음향방출기술을 이용한 현장적용 연구를 수행하였다. 또한 고장예측 진단기술, 튜브의 수명관리 및 설비 감시에 활용할 수 있도록 음향방출 진단시스템을 개발하여 현장에 설치하고, 보일러 운전상태에 따른 신호측정 및 평가, 누설위치 판별 등에 대해 고찰하였다. 누설감지는 저주파 및 고주파대역의 누설로 구분하여 음향방출신호를 각각 측정 및 평가하였다. 현장적용 연구결과로부터 실시간으로 보일러튜브 상태감시와 누설위치 추적이 가능하였으며, 향후 본 기술을 이용하면 발전설비 안전운전과 발전소 정지에 따른 경제적 손실 예방에 크게 기여할 것으로 기대된다.

액화 천연 가스 연료 선박의 연료 공급 장치 폭발 잠재 위험 분석 (Estimation of explosion risk potential in fuel gas supply systems for LNG fuelled ships)

  • 이상익
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.918-922
    • /
    • 2015
  • 선박으로부터 배출되는 오염원과 온실가스에 대한 국제적 규제가 점점 더 강화되어 감에 따라, 액화 천연 가스를 선박의 연료로 사용하는데 대한 관심이 높아져 가고 있다. 본 연구는 액화 천연 가스 연료 선박에서 사용되는 두 가지 방식의 연료 가스 공급 장치에 대하여 폭발 잠재 위험 분석을 수행하였다. 8500 TEU 급 컨테이너 선박을 목표 선박으로 선정하여, 액화 천연 가스 저장 탱크를 설계하였고 각 연료 공급 방식의 운전을 위한 압력 조건을 가정하였다. 누출공의 크기를 세 개의 범주로 분류하여, 각 누출공 크기 범주에 대한 누출 빈도를 산출하였고, 대표 누출공의 크기와 누출량을 추산하였다. 방출률의 증가와 누출 빈도는 역비례 관계를 보였으며, 펌프 방식 연료 공급 장치에서는 누출 빈도가 높게 나타났고, 가압 방식 연료 공급 장치에서는 방출률이 높게 나타났다. 전산 유체 역학 시뮬레이션을 통하여 폭발 잠재 위험 분석을 수행하고 각 연료 공급 장치에 대한 결과를 비교하였다.

Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템 (Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor)

  • 박재현;이시맥;이범주;김선주;유형민
    • Composites Research
    • /
    • 제36권6호
    • /
    • pp.429-434
    • /
    • 2023
  • 본 연구에서는 기존 배관 가스 누출 감지에 사용되던 음향방출 센서가 실시간 모니터링에 적용될 때 발생할 수 있는 문제들을 개선하기 위해, Macro-fiber composite (MFC) 트랜스듀서를 음향방출 센서로 사용하여 가스 누출 감지 시스템에 적용하였다. 적용 전 MFC의 구조를 최적화하기 위해 구조해석을 진행하여 제작하였고, 그 결과 MFC가 가지는 유연성으로 굴곡진 배관에 잘 밀착되어 AE 신호를 문제없이 수신할 수 있었다. AE 신호 분석 결과 고압 누출, 저압 누출 모두 파라미터 값 변화에 유의미한 결과를 보였으며, 특히, FFT 그래프의 파라미터에서 고압 누출의 경우 누출이 없는 경우 대비 120~626%의 변화량, 저압 누출의 경우 9~22%의 변화량을 보였다. 또한, 누출 발생 부위에서의 거리에 따라, 거리가 멀수록 이러한 파라미터 변화량이 줄어드는 경향을 보여, 추후 파라미터 변화량 감지를 통해 누출 감지가 가능할 뿐만 아니라, 변화량으로부터 누출 발생 위치를 파악할 수 있을 것으로 보인다.

음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구 (In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.315-322
    • /
    • 2008
  • 발전소 밸브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 밸브 시트(seat)면의 이물질 삽입, 시트의 균열, 스템(stem) 패킹(parking) 또는 용접부위 결함 및 피로균열 둥에 의해 누설손상이 발생하고 있다. 이러한 밸브 내부누설 상태를 정밀하게 진단하고 평가하기 위해서는 음향방출기술의 적용이 필요하며, 본 논문은 현장적용이 가능한 연구를 수행하고 그 결과를 소개하고자 한다. 또한 실제 발전소에서 운전되는 다양한 밸브 조건을 토대로 실험실 실험에 의해 주변잡음, 밸브누설시의 음향레벨 및 스펙트럼 특성을 분석하고, 발전소 현장실험 결과와의 비교분석을 통하여, 밸브 누설상태에 따른 주변잡음, 음향신호 및 측정 가능한 최소 누설검출량 등의 평가방법에 대해 고찰하였다. 실험실 실험 및 현장적용 연구결과로부터 밸브누설 여부를 포함한 상태 평가와 최소 측정가능 누설검출량 평가가 가능하였으며, 향후 본 연구는 발전설비 안전운전과 밸브누설로 인한 에너지 손실 예방에 크게 기여할 것으로 기대된다.