• Title/Summary/Keyword: High-power Fuel Cell System

Search Result 265, Processing Time 0.032 seconds

The Grid Connected Characteristics of 1.2kW Fuel-cell Converter (1.2kW급 연료전지의 전력변환기의 연계 특성)

  • Liao, Dan-Jian;Son, Gyoung-Jong;Cho, Su-Eog;Park, Sung-Jun;Choi, Joon-Ho;Moon, Chae-Joo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.438-440
    • /
    • 2007
  • This paper shows a new kind of push-pull switching converter for fuel-cell system and analyses the connected characteristics of it. In these characteristics, we are concerned about the high harmonic rate of output current, we also have designed the filter system for the inverter. Besides, the characteristics should be certified better if the ripple of the fuel-cell output current has been eliminated.

  • PDF

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

Comparison and Analysis of Boost Converter Topologies for the DC/DC Converter in Hydrogen Fuel Cell Hybrid Railway Vehicle (수소연료전지 하이브리드 철도차량용 DC/DC 컨버터를 위한 부스트 컨버터 토폴로지 비교 및 분석)

  • Kang, Dong-Hun;Lee, Il-Oun;Lee, Woo-Seok;Yun, Duk-Hyeon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.269-278
    • /
    • 2020
  • In this paper, two types of DC/DC converters in a hydrogen fuel cell hybrid railway vehicle system, which serve to charge high-voltage battery and supply power to an inverter for driving a driving motor, were compared and analyzed. A two-level interleaving boost converter and a three-level boost converter were compared and analyzed, and a theoretical design method was proposed to have an efficiency characteristic of over 95%. In addition, a digital controller design method considering the digital phase delay component of DSP (TMS320F28335) is presented. Finally, the validity of the theoretical design of the converter with 20kW power was verified through static and dynamic experiments respectively.

A Study on Performance of PEMFC with Variations on Stack Temperature and Mass Flow Rate (스택온도 및 유량변화에 따른 PEMFC의 출력특성 연구)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.140-140
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are $20{\sim}70^{\circ}C$ on stack temperature and 1~8L/min on $H_2$ volume.

  • PDF

Development of 50W Solid Oxide Fuel Cell system (50W 고체 산화물 연료전지 시스템 구축)

  • Jee, Young-Seok;Lah, Se-Yun;Cho, Goo-Young;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.311-314
    • /
    • 2009
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells, We evaluated hydrogen fed SOFC 50W system theoretically and got the results about the operating condition range from the comparison of the power efficiency, exhaust gas temperature, required heat for maintaining the operation temperature and operation time.

  • PDF

Miniature planar stack using the flexible Printed Circuit Board as current collectors (연성 기판을 전류 집전체로 사용한 평판형 연료전지 스택)

  • Kim, Sung-Han;Cha, Hye-Yeon;Miesse, Craig M.;Cha, Suk-Won;Jang, Jae-Hyuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.1-4
    • /
    • 2008
  • Fuel cells have the potential of providing several times higher energy storage densities than those possible using current state-of-the-art lithium-ion batteries, but current energy density of fuel cell system is not better than that of lithium-ion batteries. To achieve the high energy density, volume and weight of fuel cell system need to be reduced by miniaturizing system components such as stack, fuel tank, and balance-of-plant. In this paper, the thin flexible PCB (Printed circuit board) is used as a current collector to reduce the stack volume. Two end plates are made from light weight aluminum alloy plate. The plate surface is wholly oxidized through the anodizing treatment for electrical insulation. The opening rate of cathode plate hole is optimized through unit cell performance measurement of various opening rates. The performances are measured at room temperature and ambient pressure condition without any repulsive air supply. The active area of MEA is 10.08 $cm^2$ and active area per a unit cell is 1.68 $cm^2$. The peak power density is about 210 mW/$cm^2$ and the air-breathing planar stack of 2 Wis achieved as a small volume of 18 cc.

  • PDF

Electro-Thermal Model Based-Temperature Estimation Method of Lithium-Ion Battery for Fuel-Cell and Battery Hybrid Railroad Propulsion System (하이브리드 철도차량 시스템의 전기-열 모델 기반 리튬이온 배터리 온도 추정 방안)

  • Park, Seongyun;Kim, Jaeyoung;Kim, Jonghoon;Ryu, Joonhyoung;Cho, Inho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.357-363
    • /
    • 2021
  • Eco-friendly hybrid railroad propulsion system with fuel-cell and battery was suggested to reduce carbon dioxide gas and replace retired diesel railroads. Lithium-ion battery with high energy/power density and long lifetime is selected as the energy source at the battery side due to its excellent performance. However, the performance of lithium-ion batteries was affected by temperature, current rate, and operating condition. Temperature is known to be the most influential factor in changing battery parameters. In addition, appropriate thermal management is required to ensure the safe and effective operation of lithium-ion battery. Electro-thermal coupled model with varying parameter depends on temperature, and state-of-charge (SOC) is suggested to estimate battery temperature. The electric-thermal coupled model contains diffusion current using parameter identification by adaptive control algorithm when considering thermal diffusion effect. An experiment under forced convection was conducted using cylindrical cell and 18 parallel-connected battery module to demonstrate the method.

A Study on the Development of 3[kW] Power Conversion System for Fuel Cell (3[kW]급 연료전지용 전력변환기 개발에 관한 연구)

  • Kim, Se-Min;Park, Sung-Jun;Song, Sung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.88-95
    • /
    • 2009
  • This paper is the research on the development of power conversion system for the fuel cell. In composing the DC/DC converters which have high boost voltage ratio, unlike the conventional method a new multi DC/DC converter system is proposed that the diode and the condenser and the reactor can be reduced by connecting the secondary side output of the transformer. In this system the rectifier part and the filter part of the secondary side in the power transformer that is connecting in series are composed into a single module, which is the strong advantage and the number of level can be easily increased. A new variable shift phase switching method is also suggested that it makes possible to reduce the output voltage ripples in the proposed system. All the factors mentioned above have been verified through simulations and experiments, and the proposed converter is considered very useful in the demanded load which requires a wide of the output.

Experimental Studies on the Stack Cooling Performance Using a $CO_2$ Air Conditioning System in Fuel Cell Vehicles (이산화탄소 에어컨 시스템을 이용한 연료전지 자동차의 스택 냉각성능에 대한 실험적 연구)

  • Kim, Sung-Chul;Kim, Min-Soo;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.87-93
    • /
    • 2008
  • The $CO_2$ air conditioning system installed in fuel cell vehicles could be used either for stack cooling or for cabin cooling, and thus was used for the stack cooling when additional stack heat release was required over a fixed radiator capacity for high power generation. This study investigated the performance of the stack cooling system using $CO_2$ air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed for the stack cooling system using an air conditioner and compared with the conventional radiator cooling system with/without cabin cooling. The heat release of the stack cooling system with the aid of $CO_2$ air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, the heat release of the stack cooling system using $CO_2$ air conditioner increased more by 7% than that of the conventional radiator cooling system without cabin cooling.

A Study on Optimization of Reformer for kW Class SOFC System (kW급 SOFC 시스템용 개질기 최적화)

  • YI, YONG;PARK, SE JIN;KIM, MIN SOO;SHIN, JANG SIK;SHIN, SEOCK JAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.317-323
    • /
    • 2018
  • Solid oxide fuel cell (SOFC) operates at high temperature, therefor has the advantage of higher power generation and using exhaust heat than other fuel cells. In particular, the reforming reaction can be performed inside the SOFC stack to reduce the cooling of the stack and the burden on the reformer reactor. In this study, the reformer structure, operating characteristics, and thermal efficiency were evaluated for the optimization design of a heat exchanger type reformer of a 1 kW SOFC system.