• 제목/요약/키워드: High-concentration ammonia wastewater

검색결과 76건 처리시간 0.041초

폐수 내 고농도 free ammonia(FA)가 미세조류의 성장 및 기질제거에 미치는 영향 평가 (Effect of high free ammonia concentration on microalgal growth and substrate uptake)

  • 김은지;조재형;노경호;남귀숙;황선진
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.715-723
    • /
    • 2016
  • This study investigated the effect of high concentration of free ammonia on microalgal growth and substrate removal by applying real wastewater nitrogen ratio. To test of this, the conditions of free ammonia 1, 3, 6, 9, 12, 15 mg-N/L are compared. After 3 days of incubation, algal growth of Chlorella vulgaris and carbon removal rate are respectively lower in the reactors of FA 12, 15 mg-N/L compared to the others. This indicates that the high concentration of free ammonia, in this case, above 12 mg-N/L, has negative effect on algal growth and metabolic activity. Also, high concentration of free ammonia causes the proton imbalance, ammonium accumulation in algae and has toxicity for these reasons. So, we have to consider free ammonia in applying the microalgae to wastewater treatment system by the way of diluting wastewater or controlling pH and temperature.

고농도 암모니아성 질소 폐수의 효과적인 혐기성 처리를 위한 영향 인자 평가 (Estimation of influening factors for efficient anaerobic digestion of high strength ammonia-nitrogen wastewater)

  • 박세용;박정훈;나효성;김문일
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.649-658
    • /
    • 2012
  • In this study, the influencing factors for efficient anaerobic digestion of high strength ammonia-nitrogen wastewater removal were investigated by testing biochemical methane potential test. In the influencing factors, the trace metals which could increase activity of anaerobic microorganisms, microbial concentration and types were evaluated. In the results, trace metals supplementation showed gas production amount higher than those without addition of trace metals. Among the tested trace metals, B, Ni, and Se were preferable to gas production. In the result of gas production according to the microbial concentration, the amount of gas production was proportional to the microbial concentration. In addition, the shortest lag time and the fastest gas production rate were achieved when the highest microbial concentration was tested. granule-type microorganism produced more gas than suspended-type microorganism. In conclusion, the efficient anaerobic digestion for high strength ammonia-nitrogen wastewater removal could be achieved by applying necessary trace metals injection and high concentration granule type microorganism.

A Study on the Chemical Treatment Techniques of High Concentration Ammonia Nitrogen in Food Wastewater

  • Tae-Hwan JEONG;Su-Hye KIM;Woo-Taeg KWON
    • 웰빙융합연구
    • /
    • 제6권3호
    • /
    • pp.33-36
    • /
    • 2023
  • Purpose: Since the food wastewater contains a high concentration of nitrogen, it is very important to find a way to efficiently remove it. Research design, data and methodology: A total of four experiments were conducted under different conditions to remove ammonia nitrogen present in the food wastewater. The experiment was designed by adding sodium hypochlorite to the raw food wastewater and varying conditions such as pH control, aeration/precipitation, and stirring. Results: The ammonia nitrogen removal rate in Experiment 1 was about 12% (sodium hypochlorite added), ammonia nitrogen increased about 4.7% in Experiment 2 (sodium hypochlorite added after aeration/precipitation in a bioreaction tank, stirring), and decreased about 52.5% (sodium hypochlorite added after controlling and stirring). Conclusions: When the concentration of sodium hypochlorite was high, ammonia nitrogen was best removed, and the pH was adjusted to 12, and sodium hypochlorite was added after stirring, and the removal was the second best. If the method of this study is further studied and developed, it can be basic data for ammonia nitrogen removal in the future.

고농도 암모니아를 함유한 전자 폐수의 암모니아 탈기 실증 연구 (Demonstration Study on Ammonia Stripping in Electronic Industry Wastewater with High Concentrations of Ammonia Nitrogen)

  • 손재현;김영희
    • 청정기술
    • /
    • 제29권4호
    • /
    • pp.297-304
    • /
    • 2023
  • 첨단 전자 제품 산업의 비약적인 발전은 환경적 측면에서 고농도 암모니아 폐수의 증가를 초래했다. 고농도 암모니아 폐수를 안정적으로 처리하기 위해 다양한 방법의 기술이 시도되고 있으나, 지금까지 성공적인 기술이 개발되어 적용되지는 못하고 있다. 본 연구에서는 첨단 전자산업에서 발생하는 고농도 암모니아 함유 폐수에 대하여 밀폐(closed) 순환형 대향류 충전탑 형식의 실증설비를 이용하여 온도, 공기부하율 그리고 폐수부하율 변화에 따른 암모니아성 질소의 제거효율과 제거 특성을 평가하였다. 폐수량 20.8 m3 h-1, 공기량 18,000 Nm3 h-1의 운전 조건에서 온도를 45, 50, 55 그리고 60℃로 변경하여 운전한 결과, 암모니아성 질소(NH3-N)의 제거율은 각각 87.5, 93.4, 96.8 및 98.7%로 온도가 제거율에 미치는 가장 큰 영향 인자임을 알 수 있었다. 공기부하율을 증가시키면 제거율도 증가하나, 흡수탑의 액적(droplet)이 탈기탑으로 유입되어 제거율 증가는 크지 않았다. 폐수 부하율이 변경되어도 제거율은 크게 변하지 않았는데, 이는 제거율에 영향이 없는 것이 아니라, 상대적으로 높은 공기부하율에 기인한 것으로 판단된다. 실증연구를 통해 암모니아 탈기법은 첨단 전자산업에서 발생하는 고농도 암모니아 폐수를 안정적으로 처리할 수 있는 적정한 공법임을 확인할 수 있었다.

고농도 암모니아성 폐수의 질산화과정에서 아질산염 축적의 영향인자 (Factors Influencing Nitrite Build-up Nitrification of High Strength Ammonia Wastewater)

  • 한동준;강성환;임재명
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.128-138
    • /
    • 1998
  • This study was focused to find how each factors effect on the biological nitrification in wastewater treatment under high ammonia nitrogen concentration. Batch reactors in aerobic conditions were used to test the treatment efficiency of mixed liquor, nightsoil and piggery wastewater. The results are summeried as follows; Initial ammonia nitrogen concentration and pH were the direct influencing factors of nitrite build-up. More than 250 mg NH$_{4}$$^{+}$ - N/L in initial concentration built up nitrite and then the inhibition rate to Nitrobacter was above 70 percentage. And maximum nitritation rate was showed at pH 8.3 and nitrification could be completely achieved by pH control. Temperature and dissolved oxygen were the indirect influencing factors of nitrite build-up. These were a great effect on the activity of nitrifying microbes and ammonia nitrogen removal. Maximum nitritation rate was showed at 30 $\circ $C. The effect of DO concentration was negligible at more than 3 mg/L.

  • PDF

임진강수계의 수질조사 및 개선방안 (A Survey of Water Quality and Improvement Measure of Imjin-River)

  • 김형진;백영석;이준석
    • 환경위생공학
    • /
    • 제10권1호
    • /
    • pp.66-75
    • /
    • 1995
  • This survey is executed about the water quality and improvement measure of Imjin- river. The results are summarized as follows; 1 ) Ammonia nitrogen concentration in tap water was two times higher than drinking water standard. 2) The concentration of BOD in textile wastewater was 235ppm which is higher than wastewater distribution standard and leather wastewater showed high nitrogen concentration. 3) Water quality of the Imjin- river upstream was not in problem but that of Shin- stream showed somewhat high concentration in BOD, COD, and ammonia nitrogen. Especially the detected Cynide compound on the lower of Shin- stream implied seriously polluted condition. 4) The heavy metal in soil of the river bed was not detected but iron, zinc was detected to high concentration. 5) It Is urgently suggested to build more municipal sewage and sanitary treatment plants, and run dredging and river bed rearrangement project. 6) The Construction of the wastewater treatment complexes of relevant industries shall be propelled as soon as possible.

  • PDF

축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향 (Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Ammonia Nitrogen Removal and Recovery from Swine Wastewater by Microwave Radiation

  • La, Joohee;Kim, Taeyoung;Jang, Jae Kyung;Chang, In Seop
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.381-385
    • /
    • 2014
  • Microwave (MW) radiation was developed to remove and recover ammonia nitrogen in the real swine wastewater. The effect of operating parameters of MW radiation such as initial pH, power, radiation time, aeration, and stirring for removal ammonia nitrogen in swine wastewater was determined. The pH, radiation time, and power were significantly influenced on the removal of ammonia nitrogen, and aeration and stirring showed relatively minor effect on the removal of ammonia nitrogen. Optimum condition was achieved to retrieve the nitrogen efficiently at pH 11, 700 W for 5 min in MW radiation process. Through this process, 83.1% of ammonia nitrogen concentration was reduced in swine wastewater and also 82.6% of ammonia nitrogen was recovered as ammonium sulfate at the optimized condition. The high ammonia removal and recovery efficiency of the MW radiation method indicated that MW radiation was an effective technique to remove and recover ammonia nitrogen in the swine wastewater.

인 농도 및 질소원이 광합성 미세조류인 Scenedesmus dimorphus를 이용한 하수고도처리에 미치는 영향 (Effects of phosphorus concentration and nitrogen sources on photoautotrophic microalgae Scenedesmus dimorphus applied wastewater treatment)

  • 김태형;조용범;박정은;황선진
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.325-329
    • /
    • 2013
  • A result of estimating the effects of initial phosphorus concentration and nitrogen sources on removal of nitrogen and phosphorus in wastewater treatment using Scenedesmus dimorphus shows that there was no difference in microalgae growth amount and nitrogen removal amount by phosphorus concentration(5 ~ 60 mg/L). On the other hand, as initial phosphorus concentration increased, phosphorus removal amount was increased by luxury uptake of microalgae. Scenedesmus dimorphus preferred to ammonia when ammonia(40 mg/L) and nitrate(40 mg/L) are simultaneously presented and nitrogen removal rate of ammonia was high at approximately 20 mg/L/day.

도금폐수 중 시안(CN)의 선택적 제거를 위한 Ferrate (VI) 적용 (Application of Ferrate (VI) for Selective Removal of Cyanide from Plated Wastewater)

  • 양승현;김영희
    • 청정기술
    • /
    • 제27권2호
    • /
    • pp.168-173
    • /
    • 2021
  • 도금폐수의 처리는 폐수의 pH, 중금속 및 시안(CN)함유에 따라 다양하고 복잡한 공정이 적용된다. 이중 시안(CN)의 처리는 차아염소산(NaOCl)을 이용한 알칼리 염소 처리법이 일반적으로 많이 사용되고 있다. 그러나, 암모니아성 질소(NH3-N)와 시안(CN)이 동시에 함유될 경우 암모니아성 질소(NH3-N)의 처리를 위해 차아염소산(NaOCl) 이 과다하게 소비되는 문제가 있다. 이러한 문제를 해결하기 위하여 본 연구는 시안(CN)처리에 있어서 1) 알칼리염소법에서 암모니아성 질소(NH3-N)농도에 따른 차아염소산(NaOCl)의 소모량을 조사하고 2) ferrate (VI)가 시안(CN)을 선택적으로 처리할 수 있는지를 평가하였다. 모의폐수를 이용한 실험결과 알칼리염소법에서는 암모니아성 질소(NH3-N)농도가 높을수록 시안(CN)의 제거율이 감소하였으며 차아염소산(NaOCl)의 소비량이 암모니아성 질소(NH3-N) 농도에 따라 선형적으로 증가하였다. Ferrate (VI)를 이용한 시안(CN) 제거에서는 암모니아성 질소(NH3-N) 농도에 관계없이 시안(CN)의 제거를 확인하였으며 이때 암모니아성 질소(NH3-N)의 제거율은 낮아 ferrate (VI)가 시안(CN)을 선택적으로 제거함을 확인하였다. Ferrate (VI)의 시안(CN) 제거효율은 pH가 낮을수록 높게 나타났고 ferrate (VI) 주입량에 관계없이 99% 이상을 보였다. 실제 도금폐수에 적용한 결과에서는 ferrate (VI)와 시안(CN)의 투입 몰비 1:1에서 99% 이상의 높은 제거율을 보였으며 이는 화학양론 반응식의 몰비와 일치하는 결과로 모의 폐수와 동일하게 암모니아성 질소(NH3-N) 및 기타오염물질이 함유된 실제 폐수에서도 선택적으로 시안(CN)을 제거하는 것으로 확인되었다.