• 제목/요약/키워드: High-Temperature components

검색결과 1,257건 처리시간 0.032초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

가정용 소형 퇴비화용기에 의한 부엌쓰레기의 분산식 퇴비화;III. 실험실조건에서 이중벽 소형 용기에 의한 퇴비화 연구 (Decentralized Composting of Garbage in a Small Composter for Dwelling House;III. Laboratory Composting of the Household Garbase in a Small Bin with Double Layer Walls)

  • 서정윤;주우홍
    • 한국환경농학회지
    • /
    • 제14권2호
    • /
    • pp.232-245
    • /
    • 1995
  • 주택용 소형 퇴비화용기에 의한 부엌쓰레기의 퇴비화 가능성을 알아보기 위하여 두가지 용기 (Type 3 과 Type 4)를 제작하여 실험실 실험을 통하여 조사하였다. 두용기의 구조는 다 같이 용기의 벽을 이중으로 하였으며 Type 4는 보온을 하였고 Type 3은 보온을 하지 않았다. 겨울철 실험을 통하여 type 3은 우리나라의 기후여건에 사용이 불가능한 것으로 판단되어 봄철 및 여름철 실험에서 제외하였다. 따라서 Type 4에 대한 3 계절 실험결과를 요 약하면 다음과 같다. 1) 퇴비화기간 중 상승한 최고온도는 겨울 $43^{\circ}C$, 봄철 $55^{\circ}C$ 그리고 여릅철 $56^{\circ}C$ 였다. 2) 퇴비화원료물질의 무게는 8주 후 평균 63.3% 그리고 부피는 78% 감소하였다. 3) 퇴비층의 밀도는 겨울철 1.5kg/l, 봄철 0.8kg/1 그리고 여름철 0.8kg/1였다. 4) 수분함량은 전 퇴비화기간 동안 큰 변동이 없었으며 8주 후 겨울철 79.3%, 봄철 75.0% 그리고 여름철 70.0%였다. 5) pH 는 모두 첫주에 증가한 후 2주째에 감소하였다. 그 이후는 계절별 차이는 있었으나 계속 증가하였다. 8주 후 pH는 겨울철 6.19, 봄철 7.59 그리고 여름철에 8.69였다. 6) 퇴비화시간의 경과에 따른 회분 및 유기물함량은 분해속도가 빠를수록 증감현상이 뚜렷하였고 cellulose 및 lignin은 증가, hemicellulose 함량은 감소하였다. 7) 질소함량은 3.3-6.8%로 높았으며, 특히 여름철에 대단히 높았다. 암모늄태 질소함량은 전반에 증가했다가 감소하였으며 겨울철 8주째 2.404mg/kg, 봄철 3주째 12,400mg/kg 그리고 여름철 3주째 20,718mg/kg으로 가장 높았다. C/N율은 퇴비화기간의 경과에 따라 감소하였으나 차이는 크지 않았다. 여름철에 질산화가 가장 활발하였다. 8) 휘발성 및 고급유기산함량은 초기에 증가했다가 계절별로 시기적 차이는 있으나 감소하였다. 총 유기산의 최고농도는 겨울철 6주째 9.7%, 봄철 6주째 14.8% 그리고 여름철에는 2주째 15.8%였다. 9) 퇴비의 부숙도와는 무관하게 각 무기성분함량은 $P_2O_5$ 0.9-4.4%, $K_2O$ 1.6-2.4%, CaO 2.2-5.4% 그리고 MgO 0.30-0.61%였다. 10) CN 및 각종 중금속함량도 퇴비화시간의 경과에 따라 큰 변화가 없었으며 각 함량범위는 계절 구분없이 CN 0.21-14.55 mg/kg, Zn 11-166 mg/kg, Cu 5-65 mg/kg, Cd 0.5-10.8 mg/kg, Pb 6-35 mg/kg, Cr ND-33 mg/kg 그리고 Hg ND-302.04 g/kg 이였으며 중금속 역시 다른 무기성분들과 마찬가지로 퇴비화가 진행되면서 축적되지는 않았다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

파종기 차이가 보리의 등숙과 등숙관련 형질에 미치는 영향 (Effects of Sowing Date on Grain Filling and Related Traits in Winter Barley)

  • 류용환;이창덕;하용웅
    • 한국작물학회지
    • /
    • 제37권1호
    • /
    • pp.93-103
    • /
    • 1992
  • 보리의 등숙향상을 위하여 등숙효율을 높일 수 있는 형질을 선발하고 파종기를 달리 하였을 때의 등숙과정 및 등숙관련 형질들 간의 관련성을 검토하고자 특성이 상이한 보리품종인 올보리, 강보리 및 수원18호를 공시하여 시험한바 그 결과를 요약하면 다음과 같다. 1. 파종기 차이에 따른 구성 요소중 단립면적당 수수와 입중이 비교적 민감한 반응을 보였으며 만기파종에서 수량 감소가 컸다. 2. 등숙과정에서 조기와 적기파종은 출수후 20-30일 사이, 만기 파종은 출수후 1-20일 사이에서 종실의 축적량이 각각 1.03-1.94mg / grain/day과 0.88~1.88mg / grain / day 으로 가장 왕성하였으며 입중이 최대에 달하는 시기는 조기 및 적기파종에서는 출수후 40일, 만기파종은 출수후 30일경 이었다. 3. 출수이후 종실의 수석 일실량은 1.20-1.66%/day 범위로 만숙 품종과 만기파종에서 증가된 것으로 볼 때, 수분일신량과 등숙속도와는 상호밀접한 관계가 있었으며 등숙과정중 수분일실량이 가장 많은 시기는 출수후 25-30일 사이로 종실의 발육량이 최대에 이르는 시기와 일치하였다. 4. 종실의 전당 함량은 출수직후부터 직선적인 증가를 보이다가 출수후 20일을 기점으로 점차 감소됨에 동시에 전분함량은 등숙이 완료될 때까지 계속 증가되었는데 품종간에는 올보리, 강보리, 수원18호 순으로 높게 유지되었으나 파종기간에는 일정한 경향이 없었다. 5. 입중과 등숙기간과는 높은 정의 상관(r=0.767$^{**}$ )관계가 있었으나 등숙기간중의 일평균 온도(r=-0.548$^{**}$ ) 및 적산 온도(r=-0.595$^{**}$ )와는 유의한 상관관계가 인정되었다. 품종보다 노후화 속도가 느려 습윤ㆍ고온처리를 하였을 때도 하배축신장이 뚜렷하게 컸다.은 내한유채가 86.7%로 가장 높았으며, 기타(mono, di-glyceride 및 free fatty acid) 는 13.3~17.4%로 나타났다.로 빠른 시일에 집중적인 연구가 필요하다고 본다.다. 4. 저온저장(4$^{\circ}C$, RH 50%)한 벼는 2년반 저장한 벼도 밥맛의 변화가 거의 없었다. 5. 1988년산 및 1989년산 일반계를 10분도와 12분도로 도정하였을 때 도정도에 따른 밥맛의 차이는 없었다.X>$CoO_x$는 $Co_3O_4$로 존재하고, 반응 전의 경우에는 이와는 다른 chemical state를 보여주었다. XRD 및 XPS 결과를 바탕으로, 촉매표면에 존재하는 $Co_3O_4$의 외부표면이 $Co_2TiO_4$$CoTiO_3$ 같은 $CoTiO_x$로 encapsulation되어 있는 모델구조를 제안할 수 있고, 이는 반응시간의 함수로 나타나는 촉매활성에 있어서 전이영역의 존재를 잘 설명할 수 있을 뿐만 아니라, XRD와 XPS에서 얻어진 촉매의 물리화학적인 특성을 잘 반영할 수 있다. 나타냈고, 골격근과 눈 조직에서 피루브산에 대한 LDH의 친화력이 상당히 크므로 LDH가 혐기적 조건에서 효율적으로 기능을 하는 것으로 사료된다.5) and "Cleanliness of clothes & features" (p <0.05) of VIP ward were significantly higher than those of a general ward.tive to apply.아울러 고려(考慮)해야

  • PDF

추출방법에 따른 쇠비름의 항산화, 생리활성 및 Acetylcholinesterase 저해활성 (Antioxidant, Physiological Activities, and Acetylcholinesterase Inhibitory Activity of Portulaca oleracea Extracts with Different Extraction Methods)

  • 권유리;조성묵;황승필;권기만;김재원;윤광섭
    • 한국식품영양과학회지
    • /
    • 제43권3호
    • /
    • pp.389-396
    • /
    • 2014
  • 쇠비름의 활용 및 생리활성을 증가시킬 수 있는 적정 추출방법을 알아보고자 환류냉각, 가압가열 및 저온고압 추출법을 이용하여 추출한 쇠비름 70% 에탄올 추출물의 생리활성을 비교하였다. 추출수율은 환류냉각추출, 가압가열추출, 저온고압추출 순으로 높은 수율을 나타내었다. 색도에서는 저온고압추출에서 명도와 황색도가 높았고, 채도의 경우 가압가열 및 저온고압추출에서 높았다. 폴리페놀 및 프로안토시아니딘 함량은 저온고압추출이 환류냉각 및 가압가열추출에 비해 높은 함량을 나타내었으며, 플라보노이드 함량은 가압가열추출에서 높은 함량을 나타내었다. 항산화 활성은 저온고압추출이 환류냉각 및 가압가열 추출에 비해 유의적으로 높은 활성을 나타낸 반면 철 이온에 대한 제거효과의 경우 환류냉각추출 및 가압가열추출에서 높은 활성을 나타내었다. ${\alpha}$-Glucosidase 및 XO 저해활성은 저온고압추출에서 가장 높은 활성을 나타내었다. 한편 AChE 저해활성에서는 저온고압추출, 가압가열추출, 환류냉각추출 순으로 높은 활성을 나타내었고, TLC bioassay를 통하여 살펴본 결과 특정 compound들에 의해 AChE 저해 활성이 나타났으며 퇴행성 질환의 하나인 치매의 예방 가능성을 확인하였다. 이러한 결과를 종합해 볼 때 저온고압추출물이 소재 활용가치가 높을 것으로 사료되며 천연항산화제 및 기능성 증진을 위한 소재로 이용 가능할 것으로 판단된다.

레토르트 살균처리가 적색육 및 백색육 어류의 성분변화에 미치는 영향 -1. 함질소엑스분 및 텍스튜어의 변화- (Changes in Food Components of Dark, White-Fleshed Fishes by Retort Sterilization Processing -1. Changes in Nitrogenous Extractives and Textures-)

  • 오광수;성대환;최종덕;이응호
    • 한국수산과학회지
    • /
    • 제24권2호
    • /
    • pp.123-129
    • /
    • 1991
  • 수산물을 원료로 한 고온가열처리 식품의 성분 및 품질변화에 관한 기초자료를 얻을 목적으로, 가다랑어육과 명태육을 각각 마쇄 균질화하여 각 3B관에 충전, 밀봉한 후 자숙처리($98^{\circ}C$, 30분) 및 $121.1^{\circ}C$에서 Fo 5, Fo 10, Fo 20에 달하는 열처리를 하여 이들 가열처리가 어육의 함질소엑스분 및 텍스튜어의 변화에 미치는 영향에 대하여 실험하였다. 가열처리에 따른 시료 어육의 일반성분 변화에서, 수분함량은 가열처리 전에 비해 가열처리 후에, 또한 Fo값이 증가할수록 약간씩 감소하였고, 조단백질 및 조회분 함량은 상대적으로 약간씩 증가하였으며, 조지방 함량은 거의 변화가 없었다. 시료가다랑어육 및 명태육의_pH는 각각 5.46 및 6.63이었고, Fo 20 시료는 5.75 및 6.82로서 가열처리에 따라 점차 증가하였고, 휘발성염기질소량 역시 가열처리에 따라 현저히 증가하였다. 히스타민 함량은 시료 가다랑어육이 6.1mg/100g, 명태육이 0.1mg/100g이었고, 자숙처리에서는 각각 11.6mg/100g 및 0.3mg/100g, Fo 20 시료의 함량은 각각 8.2mg/100g, 0.1mg/100g이었다. 가다랑어육의 총유리아미노산의 함량은 984.8mg/100g으로 histidine, taurine, alanine, leucine 및 lysine 등이 전체의 $87\%$를 차지하고 있었고, 명태육은 총함량이 282.3mg/100g이었고, taurine, alanine, glycine, glutamic acid 및 lysine 등의 함량이 많았다. 가열처리 정도가 커질수록 이들 총함량은 약간씩 감소하였고, 가다랑어육이 명태육에 비해 감소량이 많았다. 가다랑어육에서는 histidine, taurine 및 alanine의 감소가, 명태육에서는 taurine의 감소가 현저하였다. IMP함량은 가다랑어육의 142.2mg/100g, 명태육이 95.5mg/100mg으로 시료 조제 및 가열처리 중 상당량 감소하였으며, TMAO 함량은 가열처리 중 급속히 감소한 반면, TMA는 가열 전에 비해 급증하였다. Total creatinine 함량의 변화도 비교적 현저하여 Fo 20의 열처리에서 약 $10\%$ 내외가 감소하였다. 시료 어육의 경도, 질김성, 응집성 및 탄성의 변화에서 양 시료 모두 $95^{/circ}C$에서 30분간의 열처리보다 Fo 5의 열처리 쪽이 텍스튜어의 저하가 심하였다.

  • PDF

한국 동해 남부해역 대륙붕에 서식하는 대형저서동물군집 공간분포를 결정하는 환경요인 (Environmentally Associated Spatial Distribution of a Macrozoobenthic Community in the Continental Shelf off the Southern Area of the East Sea, Korea)

  • 이정호;이정석;박영규;강성길;최태섭;김병모;류종성
    • 한국해양학회지:바다
    • /
    • 제19권1호
    • /
    • pp.66-75
    • /
    • 2014
  • 본 연구는 동해 남부 이산화탄소 해저지중저장 후보지 주변 수심 100-500 m 해역에서 저서생태계의 공간분포와 이를 결정하는 환경요인을 이해하기 위해 수행되었다. 2012년 8월-9월 총 16개 정점에서 대형저서동물군집과 환경요인을 조사하였다. 총 158종의 저서동물이 채집되었으며, 평균 서식밀도는 $843indiv/m^2$, 평균 생물량(습중량)은 $26.2g\;WW/m^2$로 나타났으며, 생물다양성이 높은 지역에서 주로 서식밀도가 높았다. 측정된 33개 환경변수를 대상으로 주성분분석을 실시한 결과 조사해역의 저서환경은 크게 퇴적물환경, 저층해수환경, 수심에 의해 지배된다. 저서동물의 분포는 세 가지 주성분과 밀접한 관련을 보였는데, 특히 사질함량이 많은 정점일수록 출현종수가 많아지고 생물량은 적어지는 경향이 관찰되었다. 조개 2종을 포함한 우점종 6종은 ${\Omega}$ aragonite, ${\Omega}$ calcite 농도가 높은 곳을 선호하였는데, 이 종들은 이산화탄소 유입으로 인해 해양산성화가 진행되면 가장 먼저 피해를 입을 수 있는 생물로 판단된다. 저서동물 상위 1% 우점종의 종조성을 바탕으로 집괴분석한 결과 지리적으로 뚜렷하게 구분되는 4개의 정점군이 분류되었다. 각 정점군은 고유의 저층해수 및 퇴적물 환경을 보이고 있으며, 대표적인 특성종으로는 A) Ampelisca miharaensis, (B) Edwardsioides japonica, (C) Maldane cristata, (D) Spiophanes kroeyeri을 들 수 있다. 측정이 용이한 5개의 환경요인(수심, 사질함량, 수온, 염분, pH)을 이용하여 4개의 정점군을 정확도 100%로 예측할 수 있는 판별함수모델을 제시하였다. 조사지역의 저서동물군집은 환경요인과 밀접한 관계를 보이고 있으며, 이는 환경변수에 기반하여 저서동물 분포를 예측할 수 있는 통계적모델 개발 가능성을 시사한다.

전북 장수군 대유 페그마타이트광산의 전기석에 포획된 유체포유물 (Fluid Inclusions Trapped in Tourmaline from the Daeyou Pegmatite Deposit, Jangsu-Gun, Jeollabukdo)

  • 이주연;엄영보;남복현;황병훈;양경희
    • 한국광물학회지
    • /
    • 제20권1호
    • /
    • pp.7-19
    • /
    • 2007
  • 전북 장수군 대유광산에 부존하는 페그마타이트내 전기석에는 네 종류의 유체포유물이 풍부하게 포획되어 있다. 유체포유물의 크기는 $5{\sim}100\;{\mu}m$이고, 상온에서 관찰되는 상(phase)의 거동에 따라 I, II, III, IV형으로 분류된다. I형은 액체가 풍부하고 기포의 크기가 50 vol% 이하인 것으로 공융온도(eutectic point)는 $-54{\sim}-29^{\circ}C$, NaCl상당 염 농도(이하염도)는 $0{\sim}12\;wt%$, 균질화온도는 $181{\sim}230^{\circ}C$이다. II형은 기포의 크기가 $80{\sim}90\;vol%$ 이상을 차지하는 포유물로서 역시 낮은 공융온도($-54{\sim}-22^{\circ}C$)를 보이며, 염도는 $3{\sim}8\;wt%$, 균질화온도는 $177{\sim}304^{\circ}C$ 범위이다. III형은 액체가 풍부하고 암염(halite)을 딸결정으로 포함하는 포유물로서 균질화온도는 $230{\sim}328^{\circ}C$, 염도는 $31{\sim}40\;wt%$이다. III형은 규산염용융포유물과 연관되어 산출되며 가열실험 중에 90% 이상의 포유물이 기포가 사라진 후에 암염이 용해되는 거동을 보인다. IV형은 $CO_{2}$를 함유하면서 칼리암염(sylvite)이나 암염을 딸결정으로 포함하는 포유물물로서 전기석에 가장 풍부하게 포획되어 있다. $CO_{2}$시스템의 밀도는 $0.80{\sim}0.75\;g/cm^{3}$, 균질화 온도는 $190{\sim}317^{\circ}C$, 염도는 $2{\sim}35\;wt%$이다. 멜트(melt)에서 가장 먼저 용리된 유체로부터 형성된 유체포유물은 규산염용융포유물과 공간적으로 연관되어 산출되는 III형이며 I형에 비해 전기석의 중앙부에서 산출되는 II형이 I형보다 먼저 포획된 것으로 추측된다. 용융체에서 용리되진 유체의 염도는 용리압력과 밀접한 관련성이 있으며, 염도의 요동(fluctuation)은 페그마타이트가 형성되는 동안 압력의 요동이 있었음을 의미한다. IV형은 가장 후기에 포획된 유체포유물이며, 광산 주변에 분포하는 석회암체 등의 변성퇴적암류로부터 $CO_{2}$ 성분과 다양한 성분의 유체가 공급되어 생성된 것으로 여겨진다. 정동이 발달하고 있지 않으며, 백운모를 함유하고 있는 대유페그마타이트는 변성작용에 의한 부분용융에 의해 형성된 멜트에서 결정화되었으며, 상당히 높은 압력의 환경에서 대유페그마타이트의 결정화작용 과정에서 용리한 유체의 성분이 전기석에 포획되어 있다. 이때 용리된 유체는 다양한 성분을 지니고 있었으며, 매우 낮은 공융온도와 다양한 딸결정은 포유물 내에 NaCl, KCl 이외에 적어도 $CaCl_{2},\;MgCl_{2}$와 같은 성분을 포함하고 있음을 지시한다. 유체의 용리는 적어도 $2.7{\sim}5.3$ kbar 이상의 압력과 $230{\sim}328^{\circ}C$ 이상의 온도에서 시작되었다.

홍삼 전분을 이용한 홍삼막걸리의 제조 및 이화학적 성분 변화 (A study on manufacturing of red ginseng Makgeolli using the red ginseng starch and changes of physicochemical components of red ginseng Makgeolli during storage periods)

  • 이환;김영수;김도연;김소영;이완규;이상명;박종대;손미례
    • 한국식품저장유통학회지
    • /
    • 제22권3호
    • /
    • pp.369-376
    • /
    • 2015
  • 본 연구에서 사용한 홍삼 전분은 홍삼 농축액 제조 공정에서 발생하는 부산물중 하나로 현재까지는 특별한 활용도가 없었다. 하지만 홍삼 농축액 제조 과정에서 발생되는 홍삼 유래의 물질로 홍삼의 유효 성분인 진세노사이드 및 각종 유리당, 탄수화물 등이 풍부한 안전한 소재로서의 가능성을 알아보고자 하였다. 홍삼전분을 이용한 새로운 홍삼막걸리의 차별화를 위하여 제품의 진세노사이드 함량, 유기산, 유리당, 효모수 등을 분석하였다. 효모 생균수의 변화 조사결과 $4^{\circ}C$에서 저장하였을 때는 저장 20일까지 효모 균수에 큰 변화가 없었지만 $25^{\circ}C$ 저장에서는 저장 20일에 초기 효모균수의 약 75%가 감소되었다. 유기산분석 결과 막걸리에서는 lactic acid가 4.16 mg/mL의 농도로 가장 많았으며, 그 다음으로는 citric acid 0.88 mg/mL, malic acid 0.39 mg/mL의 순서로 많았다. 저장 초기에는 malic acid의 함량이 $4^{\circ}C$$25^{\circ}C$에서 0.39 mg/mL 와 0.58 mg/mL 이었으나 저장일이 20일 경과하였을 때에는 0.46 mg/mL 그리고 0.17 mg/mL으로 측정되었고 대부분의 유기산은 저장기간에 관계없이 변화가 크게 나타나지 않았으나 butyric acid는 증가를 보였다. 20일 경에 lactic acid와 isobutyric acid는 감소하였으며 다른 종류의 유기산은 증가를 보였다. 유리당 분석결과 glucose가 4.4 mg/mL, sucrose 2.8 mg/mL 그리고 mannose 1.4 mg/mL 으로 막걸리의 주 구성당으로 분석되었으며 저장기간이 지속되면서 sucrose, glucose, mannose의 함량은 감소를 보여 알콜 발효의 주요 기질로 사용되었음을 보여주었다. 저장 4~8일 이후부터는 당이 급격히 감소하였으며 8일 이후부터는 큰 차이를 보이지 않았다. 이것은 저장 중 당분이 알콜과 탄산가스로 분해되었기 때문에 함량이 감소한 보여진다. $4^{\circ}C$에서 저장시, 일반적인 유통기간보다(10일) 긴 20일 동안 유리당의 변화를 보였으며 유리당은 12일 경에 sucrose, glucose와 mannose의 양은 1/2으로 감소하였다. 총산 및 pH 분석결과 각 저장온도에서 저장기간에 따른 pH의 변화는, $4^{\circ}C$에서 저장한 경우, 저장 4일경 pH 4.3에서 8일경 pH 3.8로 떨어지면서 저장기간 동안 서서히 감소되었다. $25^{\circ}C$에서 저장한 경우, pH 4.6~3.2 수준으로 $4^{\circ}C$ 저장 온도보다 $25^{\circ}C$ 온도에서 pH가 낮게 관찰 되었고 진세노사이드 분석결과 함량은 2.47 mg/g으로 측정되었다.

세탁세제 첨가용 효소 개발을 위한 남극 해양세균 유래 저온성 단백질분해효소의 특성 연구 (Characterization of an Antarctic alkaline protease, a cold-active enzyme for laundry detergents)

  • 박하주;한세종;임정한;김덕규
    • 미생물학회지
    • /
    • 제54권1호
    • /
    • pp.60-68
    • /
    • 2018
  • 남극 해양세균 Pseudoalteromonas arctica PAMC 21717로부터 저온활성 alkaline protease (Pro21717)를 부분정제하였다. Pro21717 효소 추출액은 skim milk를 포함하는 zymogram gel 상에서 약 37 kDa (낮은 활성)과 74 kDa (높은 활성) 위치에서 두 개의 뚜렷한 투명밴드(clear zone)를 형성하였다. 단백질 분해활성을 나타내는 두 개의 효소단백질은 동일한 N-말단 아미노산 서열을 가지고 있었으며, 하나의 유전자에서 발현된 미성숙 단백질(precursor)이 37 kDa 크기의 단백질분해효소로 성숙화과정을 거친 후 74 kDa 크기로 이량체화됨으로써 좀 더 높은 활성을 가지는 것으로 판단된다. Pro21717은 $0-40^{\circ}C$ (최고활성 온도 $40^{\circ}C$) 온도 범위에서 단백질분해활성을 나타내었고 pH 5.0-10.0 (최적 pH 9.0) 범위에서 효소활성을 유지하였다. 주목할만한 특성으로써, Pro21717은 $40^{\circ}C$에서의 최고 효소활성(100%) 대비, $0^{\circ}C$$10^{\circ}C$에서 각각 30%와 45%의 높은 저온활성을 나타내었다. 또한 다양한 합성 펩타이드류에 대해 분해활성을 나타내는 Pro21717은 $Cu^{2+}$에 의해 활성이 증가하였으며, 시판용 세탁세제(commercial detergent formulation)에 포함되어 있는 다양한 종류의 계면활성제, 화학성분, 금속이온에 의해 활성이 감소되지 않았다. 전반적으로 저온활성 Pro21717은 글로벌 상업용효소 생산회사 Novozymes이 시판하고 있는 중온성 효소 Subtilisin Carlsberg (trademark Alcalase)에 버금가는 유용한 효소학적 특성이 있는 동시에 상대적으로 더 높은 저온활성을 보여주고 있다. 위의 실험결과들은, Pro21717은 $15^{\circ}C$ 이하의 차가운 수돗물에서도 세척력을 유지하는 새로운 세탁세제 효소첨가제로서의 개발 가능성을 보여주고 있다.