• Title/Summary/Keyword: High-Performance Work System

Search Result 713, Processing Time 0.029 seconds

Study on Low Pressure Loop EGR System for Heavy-duty Diesel Engine to Meet EURO-5 NOx Regulation (LPL EGR System 적용 대형 디젤엔진의 EURO-5 NOx 규제대응에 관한 연구)

  • Lee, K.S.;Baek, M.Y.;Park, H.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • Recently, many small and medium size diesel vehicles have been equipped with turbocharger and EGR system to get high performance and reduce $NO_x$ emissions but its application to heavy-duty diesel engine is not common yet. In this work, the simulation model for EURO-3 engine was developed using WAVE and then its performance and emission level were verified by comparing with experimental results. The possibility of current EURO-3 engine equipped with LPL EGR system which would be satisfied the EURO-5 regulation are examined. ESC 13 mode was chosen as the primary engine test mode, and the injection timing and fuel quantity were changed to compensate the lost engine performance caused by EGR. The system developed in this study shows that the current EURO-3 engine could satisfy EURO-5 $NO_x$ regulation by applying LPL EGR.

  • PDF

Experimental Study on the Performance Characteristics of an Injection Type Scroll Compressor (인젝션용 스크롤 압축기의 성능특성에 관한 실험적 연구)

  • Cho, Hong-Hyun;Kim, Yong-Chan
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.193-198
    • /
    • 2000
  • For an inverter-driven compressor, the discharge temperature increased with a rise of frequency, Therefore, it is necessary to control the discharge temperature at high frequencies in order to obtain system reliability and efficiency. This paper describes the effects of liquid injection system on the performance of an inverter-driven scroll compressor. Experiments were performed at ASHRAE-T conditions. Frequency was altered from 45 to 105Hz. As results of the present work, the refrigerant discharge temperature fur the injection system was dropped approximately $10{\sim}20^{\circ}C$ as compared to those for the non-injection system. The COP of the compressor was improved approximately $0.8{\sim}9.3%$ at high frequencies(75, 90, and 105 Hz).

  • PDF

A Study on Improving Plan of the Evaluating System for Efficient Defense M&S Accreditation Work (효율적인 국방M&S 인정업무 수행을 위한 평가시스템 발전방안 연구)

  • Han, Seung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.42-48
    • /
    • 2021
  • Recently, the defense industry has been improving high technology by developing convergence technology through the 4th industrial revolution. On the other hand, it is very difficult to guarantee the performance of high-tech weapon systems because the test for weapon systems has many risks and cannot perform in an actual operating environment. Therefore, M&S resources are needed to make sound weapon systems, but many people demand reliable M&S resources. Owing to the continuous demand and execution of the VV&A work, related rules have developed significantly, but tools and techniques for performing the work have not been developed. Hence, there are inefficient parts in the performance of work due to the absence of a systematic system. Accordingly, many risks may cause various safety accidents, such as security. This paper suggests a direction for the development of VV&A work procedures by improving efficiency and reducing risk.

Studies on the Performance Characteristics of an Electronically Controlled $CO_2$ Air Conditioning System for Fuel Cell Electric Vehicles (연료전지 자동차용 전자 제어식 $CO_2$ 냉방 시스템의 성능 특성에 관한 연구)

  • Kim, Sung-Chul;Lee, Dong-Hyuk;Lee, Ho-Seong;Won, Jong-Phil;Lee, Dae-Woong;Lee, Won-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.150-157
    • /
    • 2008
  • The main objective of this paper is to investigate the performance characteristics of a $CO_2$ air conditioning system for fuel cell electric vehicles (FCEV). The present air conditioning system for FCEV uses the electrically driven compressor and electrically controlled expansion valve for $CO_2$ as a working fluid. The experimental work has been done with various operating conditions, which are quite matching the actual vehicle's driving conditions such as different compressor speed and high pressure to identify the characteristics of the system. Experimental results show that the cooling capacity and coefficient of performance (COP) were up to 6.3kW and 2.5, respectively. This paper also deals with the development of optimum high pressure control algorithm for the transcritical $CO_2$ cycle to achieve the maximum COP.

Analysis of the Operation Performance of the Construction Safety System by Using Construction Accident Data (건설공사 사고 데이터(CSI) 활용을 통한 건설안전제도(안전관리계획서)의 운영성과 분석)

  • Kim, Seong-Deok;Cho, A-Yeong;Lee, Jeong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.383-384
    • /
    • 2023
  • Using the CSI(Construction Safety Management Integrated Information) data, a comparative analysis was conducted by work type and construction cost according to whether the construction sites were subject to making a safety management plan or not. As a result, by type of work, the ratio of deaths in non-plan sites was high in mechanical facilities and earthworks, and the operation performance of the system was much higher in sites that were less than 5 billion won of construction cost.

  • PDF

A Study on the Importance of Works Perceived by Quality Improvement Coordinators and Their Current Work Performances (질 관리 실무자가 인지하는 업무중요도와 수행업무에 관한 연구)

  • Kim, Young Ju
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.224-237
    • /
    • 1998
  • Background : This is an investigative study to analyse the importance of works perceived by Quality Improvement(QI) Coordinators and to evaluate their current work performances using the questionnaires developed by the investigator. Methods : The data were collected from 37 subjects over two weeks period from Oct. 1 to Oct. 17, 1998 and analysed by the descriptive statistics of SPSS program. The items of questionnaire are consisted of 13 work domains including 73 activities based on Quality Management(QM) Coordinator's job description of National Association for Healthcare Quality:data collection & analysis, communication, monitoring, evaluation, accreditation, tool development, policy development, program development, self development, education & trainning, system design, planning, and consultation & support. Results : 1) Of the performances in 13 work domains, the frequencies of the work performed were accreditation(89%), planning(88%), communication(83%), data collection & analysis(82%), monitoring(76%), policy development(72%), consultation & support (71%), education & trainning(70%), self development(68%), evaluation(63%), tool development(61%), program development(44%) and system design(43%) in order. 2) For the importances (1=not important, 5=very important), the policy development(4.46) scored highest then monitoring(4.42), planning(4.41), education & trainning(4.38), communication(4.35), evaluation(4.34) tool development (4.30), data collection & analysis(4.29), program development(4.22), consultation & support(4.22), accreditation(4.15), self development(4.05) and system design(3.98) in order. 3) There was a difference between the work performance and the perceived importance. The results showed the low performances in policy development, monitoring, education & trainning and evaluation which ranked high by the perceived importance and the high performances in accreditation, data collection & analysis, self development, communication and consultation & support which ranked middle to low by the perceived importance. 4) The reasons for low performances of QI Coordinators were the lack of clear assignment for the responsibility and allowed authority for work to QI Coordinators(30.8%), insufficient member of QI Coordinators(13.9%), lack of hospital director's interest(11.5%), low motivation of QI Coordinators (10.6%) and insufficient knowledge & experience of QI Coordinators (8.8%). Conclusion : Most works were perceived important by QI Coordinators, but there was a difference in the work performance. The works performed over 70% were related with accreditation, data collection & analysis, communication, planning and monitoring, on the other hand under 50% in performances were related with system design, program development, tool development and evaluation.

  • PDF

Performance Characteristics Analysis of Gas Turbine-Pressurized SOFC Hybrid Systems (가스터빈-가압형 SOFC 하이브리드 시스템의 성능특성 해석)

  • 양원준;김동섭;김재환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.615-622
    • /
    • 2004
  • Recently, the hybrid system combining fuel cell and gas turbine has drawn much attention owing to its high efficiency and ultra low emission. It is now on the verge of world wide development and various system configurations have been proposed. A national project funded by Korean government has also been initiated to develop a pressurized hybrid system. This work aims at presenting design performance analysis for various possible system configurations as an initial step for the system development. Study focuses are given to major design options including the power ratio between gas turbine and fuel cell, reforming method (internal or external), reforming heat source (reforming burner, cathode hot air, fuel cell heat release) and steam supply method for reformer (anode gas recirculation, external steam generator). A wide variation in performance among different configurations has been predicted.

A Study on Determining of Job Sequence by Work Sampling(I) (W.S법에 의한 JOB SEQUENCE의 결정(I))

  • 강성수;노인규
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.11 no.18
    • /
    • pp.59-69
    • /
    • 1988
  • This study represents the method of application of W.S(Work Sampling) to determine job sequence. The result shows job sequence which has the came performance measure of optimal job sequence is selected by average number of 199 sampling. In the case, the optimal job sequence is not selected within the sampling number of 921 which satisfy the reliability of 99.5% and precision of 99%, the deviation is very little which 0.73%. This improves the possibility of application of W.S method to select optimal job sequence is very high.

  • PDF

Reconfigurable Multi-Array Architecture for Low-Power and High-Speed Embedded Systems

  • Kim, Yoon-Jin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.3
    • /
    • pp.207-220
    • /
    • 2011
  • Coarse-grained reconfigurable architecture (CGRA) based embedded systems aims to achieve high system performance with sufficient flexibility to map a variety of applications. However, the CGRA has been considered as prohibitive one due to its significant area/power overhead and performance bottleneck. In this work, I propose reconfigurable multi-array architecture to reduce power/area and enhance performance in configurable embedded systems. The CGRA-based embedded systems that consist of hierarchical configurable computing arrays with varying size and communication speed were examined for multimedia and other applications. Experimental results show that the proposed approach reduces on-chip area by 22%, execution time by up to 72% and reduces power consumption by up to 55% when compared with the conventional CGRA-based architectures.

Development of Evaluation System and Program for the Performance of Micro Optical Filters (미소 광필터 성능평가 시스템 및 프로그램 개발)

  • Park, Han-Su;Seo, Yeong-Ho;Choe, Du-Seon;Je, Tae-Jin;Hwang, Gyeong-Hyeon
    • 연구논문집
    • /
    • s.33
    • /
    • pp.111-122
    • /
    • 2003
  • The automatic assembly system of micro optical filter is a key technology in the development of optical modules with high functionality. In order to create such automatic assembly system of optical filter, we have developed the system and program capable of evaluation of $30\mum$-thick film optical filter as well as conventional optical filters performances. Moreover, we have carried out the evaluation of optical filter using developed system and program, and we have compared and analyzed them with by conventional hand work. As results, the measured performances based on the present system are more fast, precise and reliable then those of the conventional hand work. In addition to that, the system can apply for various optical collimators and filters.

  • PDF