• Title/Summary/Keyword: High sensitivity

Search Result 4,958, Processing Time 0.047 seconds

A comparative study of dose distribution for whole brain with field-in-field technique (전뇌(Whole Brain)치료 시 Field-in-Field Technique 적용에 관한 고찰)

  • Kim Bo Kyoum;Lee Je Hee;Jung Chi Hoon;Pack Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • Purpose : Uniform dose distribution of the target volume is very important in the radiation treatment. We will evaluate the usefulness of Field-in-Field Technique use to get uniform dose distribution of the target volume and try to find Apply possibility out to a whole brain treatment patient of various thickness. Material and method : We compare the dose distribution when we applied Field-in-Field Technique and parallel opposed fields technique. establish the treatment plan to a phantom(acryl 16cm spheral phantom) and do the measurement, assessment use the TLD and Low sensitivity film. Also the assessment did Apply possibility of Field-in-Field Technique to 20 patient object of various thickness. Result : In the case to use the parallel opposed fields at the whole brain treatment $10-12\%$ high dose region appeared but reduce to $3-4\%$ lesses when we used the Field-in-Field technique. We could get similar numerical value the film and TLD measurement result also. The change of the dose distribution appeared to its ${\pm}1{\sim}2\%$ although it applied such Field-in-Field technique to various patient so that we were identical. Conclusion : We can get uniform dose distribution of in the treatment region if we apply the Field-in-Field technique at the whole brain treatment. Also alternate can play the role of the wedge filter and 3D compensator and We are thought by minimizing the obstacle to be happened due to the high dose region when radiation treatment.

  • PDF

Urinary Tract Infection in Febrile Infants with Pyuria (발열과 농뇨가 있는 영아에서 요로감염에 관한 연구)

  • Lee, Sue Young;Cho, Sung Hee;Kim, Sun Mi;Jeong, Dae Chul;Chung, Seung Yeon;Lee, Kyung Yil;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.1
    • /
    • pp.90-100
    • /
    • 2004
  • Objective : Urinary tract infection(UTI) is a frequent serious bacterial infection in young infants. The clinical presentation may be non-specific and variable, depends on factors such as the age and the level of infection. Children with renal involvement may be at risk of permanent renal damage. Experimental studies have shown that renal lesions caused by acute febrile UTI may be prevented or diminished by early diagnosis and treatment. Therefore, it is important to find a method that can permit early diagnosis and identification of patients who are at risk for progressive renal damage. We designed this study to identify related factors in culture positive UTI infants, and also to identify related factors in culture negative UTI infants, who are febrile with pyuria, by using renal imaging and functional studies including renal sonography, DMSA scan and VCUG. Methods : Retrospectively analyzed the medical records of 136 febrile infants with pyuria over 2 years(from January 2001 to February 2003). Urine culture was done in all cases, and regardless of urine culture findings, renal imaging study was done if symptomatic UTI suspected. Results : Total 57 organisms were isolated in 53 patients. E. coli was the most common organism(86%), followed by E. faecalis, M. morganii, Proteus species, P. aeruginosa, S. aureus and E. fergusonii. Most of the isolates had high sensitivity on cephalosporins or amikacin and had low sensitivities on aminopenicillins. Abnormal acute phase DMSA scan or VCUG findings were seen in both urine culture positive and negative group without statistical differences(P>0.05). In febrile infants with pyuria, fever over 48 hours, older age and high CRP related to abnormal acute phase DMSA scan findings regardless urine culture results. Conclusion : 1st or 3rd generation cephalosporins with amikacin could be the first choice of treatment for UTI. Febrile infants with positive urine culture dose mean urinary tract infection but not acute pyelonephritis which directly relates to cortical damage which could be confirmed by acute phase DMSA scan. Even cases with negative urine culture findings, acute pyelonephritis should be concerned in febrile infants with pyuria who are older than 3 months of age, has fever over 48 hours or high CRP level. And in such cases, acute phase DMSA scan and VCUG should be evaluated for early treatment and long term prognosis.

  • PDF

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

Regulation of Gb3 Expression on Dendritic Cells (수지상세포에 있어서 베로독소 수용체의 발현조절)

  • Lim, Suk-Hwan;Kim, Gi-Young;Kim, Hyung-Chun;Kim, Young-Hee;Son, Yong-Hae;Oh, Yang-Hyo;Park, Yeong-Min
    • Journal of Life Science
    • /
    • v.17 no.4 s.84
    • /
    • pp.482-492
    • /
    • 2007
  • Infection with Shiga-like toxin (SLT)-producing Escherichia coli causes a spectrum of illnesses with high morbidity and mortality. Host mediators play an important role in the pathogenesis of SLT-I toxicity. We here investigated the effect of SLT-I on tumor necrosis $factor-{\alpha}\;(TNF-{\alpha})$ production, effect of $TNF-{\alpha}$ on glycolipid globotriaosyleramide (Gb3) expression, and relationship between Gb3 level and differential susceptibility of cells to SLT-I. In this study, we observed that detectable levels of $TNF-{\alpha}$ are produced 6 hrs after induction and continued to increase during 48 hrs by SLT-I. It was also found that Vero cells and dendritic cells expressed high levels of Gb3, 83% and 68%, respectively, and that macrophages had a low level of Gb3 (29%) and showed refractory to cytotoxicity against SLT-I. Vero cells and dendritic cells expressing high levels of Gb3 were highly susceptible to SLT-I. furthermore, macrophages showed a resistance to SLT-I cytotoxicity, despite the fact that Gb3 expression was enhanced. These results suggest that the expression of Gb3 is necessary, but not sufficient to confer sensitivity of macrophages to SLT-I and further underpin the important role of SLT-I and its receptor, Gb3, in the pathogenesis of E. coli O157 infection.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

Diffuse Infiltrative Lung Disease : Comparison of Diagnostic Accuracies of High-Resolution CT and Radiography (미만성 침윤성 폐질환의 진단: HRCT와 단순흉부X선사진의 비교)

  • Kim, Kyeong-Ah;Kang, Eun-Young;Oh, Yu-Whan;Kim, Jeung-Sook;Park, Jai-Soung;Lee, Kyung-Soo;Kang, Kyung-Ho;Chung, Kyoo-Byung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.388-402
    • /
    • 1996
  • Background : To compare the diagnostic accuracies of High-resolution CT(HRCI) and chest radiography in the diagnosis of diffuse infiltrative lung disease(DILD). Methods : This study included ninety-nine patients with a diagnosis of acute or chronic DILD, representing 20 different diseases. Twelve normal subjects were included as control. The disease state was confirmed either pathologically or clinically. Radiographs and CT scans were evaluated separately by three independent observers without knowledge of clinical and pathologic results. The observers listed three most likely diagnoses and recorded degree of confidence. Results : The sensitivity of HRCT in the detection of DILD was 98.9% compared to 97.9% of chest radiography. Overall, a correct first-choice diagnosis was made in 48% using chest radiographs and in 60% using HRCT images. The correct diagnosis was among the top-three choices in 64% when chest radiographs were used, and in 75% when HRCT images were reviewed. Overally a confident diagnosis was reached more often with HRCT(55%) than with chest radiography(26%). The correct first-choice diagnosis increased remarkably when the HRCT was used in usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis and lymphangitic carcinomatosis. Conclusion : HRCT is confirmed to be superior to conventional radiography in the detection and accurate diagnosis of DILD. HRCT is especially valuable in the diagnosis of usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis, and lymphangitic carcinomatosis.

  • PDF

A Study on the DC Resistivity Method to Image the Underground Structure Beneath River or Lake Bottom (하저 지반특성 규명을 위한 수상 전기비저항 탐사에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Choi Seong-Jun;Lee Seoung Kon;Son Jeong-Sul;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.223-235
    • /
    • 2002
  • Since weak Bones or geological lineaments are likely to be eroded, there may develop weak Bones beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. DC resistivity method, however, has seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of a case history, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing them at the water bottom, because the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the DC resistivity method can provide fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio (S/N ratio) data as well as the high resolving power. Some of the modified electrode arrays can provide the data having reasonably high S/N ratio and need not to install remote electrode(s), and thus, they may be suitable to the resistivity survey at the water-covered area.

Characterization of HtrA2-deficient Mouse Embryonic Fibroblast Cells Based on Morphology and Analysis of their Sensitivity in Response to Cell Death Stimuli. (HtrA2 유전자가 결손된 mouse embryonic fibroblast 세포주의 형태학적 특징 및 세포사멸 자극에 대한 감수성 조사)

  • Lee, Sang-Kyu;Nam, Min-Kyung;Kim, Goo-Young;Rhim, Hyang-Shuk
    • Journal of Life Science
    • /
    • v.18 no.4
    • /
    • pp.522-529
    • /
    • 2008
  • High-temperature requirement A2(HtrA2) has been known as a human homologue of bacterial HtrA that has a molecular chaperone function. HtrA2 is mitochondrial serine protease that plays a significant role in regulating the apoptosis; however, the physiological function of HtrA2 still remains elusive. To establish experimental system for the investigation of new insights into the function of HtrA2 in mammalian cells, we first obtained $HtrA2^{+/+}$ and $HtrA2^{-/-}$ MEF cells lines and identified those cells based on the expression pattern and subcellular localization of HtrA2, using immunoblot and biochemical assays. Additionally, we observed that the morphological characteristics of $HtrA2^{-/-}$ MEF cells are different form those of $HtrA2^{+/+}$ MEF cells, showing a rounded shape instead of a typical fibroblast-like shape. Growth rate of $HtrA2^{-/-}$ MEF cells was also 1.4-fold higher than that of $HtrA2^{+/+}$ MEF cells at 36 hours. Furthermore, we verified both MEF cell lines induced caspsase-dependent cell death in response to apoptotic stimuli such as heat shock, staurosporine, and rotenone. The relationship between HtrA2 and heat shock-induced cell death is the first demonstration of the research field of HtrA2. Our study suggests that those MEF cell lines are suitable reagents to further investigate the molecular mechanism by which HtrA2 regulates the balance between cell death and survival.

A New Malting Barley Variety, "Daho" with High Yielding and BaYMV Resistance (맥주보리 호위축병저항성 및 다수성 "다호")

  • Hyun, Jong-Nae;Kim, Mi-Jung;Kim, Yang-Kil;Lee, Mi-Ja;Choi, Jae-Sung;Kim, Hyun-Tae;Han, Sang-Ik;Ko, Jong-Min;Lim, Sea-Gyu;Park, Jong-Chul;Kim, Jung-Gon;Suh, Sae-Jung;Kim, Dae-Ho;Kang, Sung-Ju;Kim, Sung-Taeg
    • Korean Journal of Breeding Science
    • /
    • v.41 no.3
    • /
    • pp.333-337
    • /
    • 2009
  • A new malting barley variety, "Daho", was developed from the cross between "Milyang85 and Suwon335" at the Department of Rice and Winter Cereal Crop (DRWCC) NICS, in 2007. An elite line, YMB2064-B-8-2-4-1-1, was selected in 2004 and designated as "Milyang134". It showed good agronomic performance in the regional adaptation yield trials (RYT) from 2005 to 2007 and was released with the name of "Daho", having high yielding and BaYMV resistance. The average heading and maturing dates of "Daho" were April 19 and May 27, which were 2 days later and 1 day earlier than those of "Jinyang", leading variety, at the regional adaptation yield trials (RYT), respectively. "Daho" had longer culm length (84 cm), more spikes per $m^2$ (915) and higher 1,000 grain weight (39.2 g) than those of "Jinyang" in paddy field condition. "Daho" was showed resistance to BaYMV at the regions of Naju, Jinju, and Milyang but moderately resistance at Iksan. However, the response of "Daho" to other environmental stresses was similar to "Jinyang". The yields of "Daho" at upland and paddy fields were about 5.20 MT/ha, 4.81 MT/ha, respectively, which is about 38%, 25% higher than those of "Jinyang" in the regional adaptation yield trials (RYT), respectively. It has higher grain assortment, germination capacity, water sensitivity and Kolback index but lower malt extract, diastatic power and filtration speed than those of "Jinyang".