• 제목/요약/키워드: High sensitive

검색결과 3,126건 처리시간 0.038초

Highly Stretchable and Sensitive Strain Sensors Fabricated by Coating Nylon Textile with Single Walled Carbon Nanotubes

  • Park, Da-Seul;kim, Yoonyoung;Jeong, Soo-Hwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.363.2-363.2
    • /
    • 2016
  • Stretchable strain sensors are becoming essential in diverse future applications, such as human motion detection, soft robotics, and various biomedical devices. One of the well-known approaches for fabricating stretchable strain sensors is to embed conductive nanomaterials such as metal nanowires/nanoparticles, graphene, conducting polymer and carbon nanotubes (CNTs) within an elastomeric substrate. Among various conducting nanomaterials, CNTs have been considered as important and promising candidate materials for stretchable strain sensors owing to their high electrical conductivity and excellent mechanical properties. In the past decades, CNT-based strain sensors with high stretchability or sensitivity have been developed. However, CNT-based strain sensors which show both high stretchability and sensitivity have not been reported. Herein, highly stretchable and sensitive strain sensors were fabricated by integrating single-walled carbon nanotubes (SWNTs) and nylon textiles via vacuum-assisted spray-layer-by-layer process. Our strain sensors had high sensitivity with 100 % tensile strain (gauge factor ~ 100). Cyclic tests confirmed that our strain sensors showed very robust and reliable characteristic. Moreover, our SWNTs-based strain sensors were easily and successfully integrated on human finger and knee to detect bending and walking motion. Our approach presented here might be route to preparing highly stretchable and sensitive strain sensors with providing new opportunity to realize practical wearable devices.

  • PDF

UHF 대역 RFID 시스템용 고감도 광대역 태그 안테나의 설계 (Design of High Sensitive Broadband Tag Antenna for RFID System in UHF Band)

  • 박건도;민경식
    • 한국항해항만학회지
    • /
    • 제33권1호
    • /
    • pp.51-56
    • /
    • 2009
  • 본 논문은 UHF 대역 RFID 시스템용 고감도 광대역 태그 안테나의 설계에 대하여 기술한다. 제안된 태그 안테나의 크기는 $60\;mm\;{\times}\;10\;mm\;{\times}\;1\;mm$이다. 공진 주파수는 910 MHz 이고, - 10 dB이하 대역폭은 약 900 MHz이다. 측정된 반사손실과 지향성 패턴은 계산결과 잘 일치하는 것으로 확인되었다. 칩을 가진 제안한 태그 안테나의 인식거리는 6.5 m로 관측되었으며, 이 값은 상용 태그 안테나의 인식거리보다 평균 0.5 m이상 멀리 감지된 결과이다.

Methylation-sensitive high-resolution melting analysis of the USP44 promoter can detect early-stage hepatocellular carcinoma in blood samples

  • Si-Cho, Kim;Jiwon, Kim;Da-Won, Kim;Yanghee, Choi;Kyunghyun, Park;Eun Ju, Cho;Su Jong, Yu;Jeongsil, Kim-Ha;Young-Joon, Kim
    • BMB Reports
    • /
    • 제55권11호
    • /
    • pp.553-558
    • /
    • 2022
  • Hepatocellular carcinoma (HCC) is dangerous cancer that often evades early detection because it is asymptomatic and an effective detection method is lacking. For people with chronic liver inflammation who are at high risk of developing HCC, a sensitive detection method for HCC is needed. In a meta-analysis of The Cancer Genome Atlas pan-cancer methylation database, we identified a CpG island in the USP44 promoter that is methylated specifically in HCC. We developed methylation-sensitive high-resolution melting (MS-HRM) analysis to measure the methylation levels of the USP promoter in cell-free DNA isolated from patients. Our MS-HRM assay correctly identified 40% of patients with early-stage HCC, whereas the α-fetoprotein test, which is currently used to detect HCC, correctly identified only 25% of early-stage HCC patients. These results demonstrate that USP44 MS-HRM analysis is suitable for HCC surveillance.

DEVELOPMENT OF POSITION-SENSITIVE PROTON RECOIL TELESCOPE (PSPRT)

  • Miura, Takako;Baba, Mamoru;Kawata, Naoki;Sanami, Toshiya
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.161-165
    • /
    • 2001
  • We have developed a position-sensitive proton recoil telescope (PSPRT) which employs a position-sensitive photomultiplier (PS-PMT) and a scintillator for both a radiator and a proton-detector. This system is expected to achieve high energy resolution under a large solid angle, because it enables to obtain the information not only on the proton energy but also the recoil angle from the position data for both detectors. The response of the PSPRT for 14.1 MeV mono-energetic neutrons was measured, and the PSPRT proved to be operating as expected.

  • PDF

중국 북경 소비자의 샤인머스캣 구매의향 결정요인 및 가격민감도 분석 (A Study on Factors Affecting Purchase Intention and Price Sensitivity Analysis of Korean Shine-muscat for Consumers in Beijing China)

  • 이정명;김승규;최세현
    • 한국유기농업학회지
    • /
    • 제28권2호
    • /
    • pp.155-170
    • /
    • 2020
  • The objective of this study is to analyze factors affecting purchase intention and conduct price sensitivity analysis of Korean Shine-muscat for Chinese consumers. Logit model has been set up to find purchase intention with survey data which was conducted in Beijing China. The results show that the high-income, unmarried consumers are more sensitive to the price of Korean Shine-muscat than low-income, married consumers, but have higher purchase intention. Also, consumers who perceive Korea positively and those who prefer Korean dramas are more sensitive to the price but have higher purchase intention. Consumers with a high monthly purchase frequency of Shine-muscat have higher purchase intention of Korean Shine-muscat, but are more sensitive to the price. The results of this study can be utilized as basic information for promoting the export of Korean Shine- muscat to China.

폭염이 일사망자수에 미치는 영향에 관한 연구 (A Study on the Influence of Extreme Heat on Daily Mortality)

  • 박종길;정우식;김은별
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.523-537
    • /
    • 2008
  • In Korea, the global warming leads to more frequent high temperature region. increasing the need for research into physical damage caused by high temperature. We therefore analyzed the differences of mortality, caused by extreme heat, among gender and age. We also examined the trend of mortality from high temperature-sensitive diseases. Women are more affected by exposure to high temperature than are men; People over 65 years old have higher mortality rate (1.5 times) than under 65. As for high temperature-related diseases, cerebrovascular disease was the number one cause of death, and chronic lower respiratory disease and cardiovascular disease followed.

Wafer-Level Packaged MEMS Resonators with a Highly Vacuum-Sensitive Quality Factor

  • Kang, Seok Jin;Moon, Young Soon;Son, Won Ho;Choi, Sie Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.632-639
    • /
    • 2014
  • Mechanical stress and the vacuum level are the two main factors dominating the quality factor of a resonator operated in the vacuum range 1 mTorr to 10 Torr. This means that if the quality factor of a resonator is very insensitive to the mechanical stress in the vacuum range, it is sensitive to mainly the ambient vacuum level. In this paper, a wafer-level packaged MEMS resonator with a highly vacuum-sensitive quality factor is presented. The proposed device is characterized by a package with out-of-plane symmetry and a suspending structure with only a single anchor. Out-of-plane symmetry helps prevent deformation of the packaged device due to thermal mismatch, and a single-clamped structure facilitates constraint-free displacement. As a result, the proposed device is very insensitive to mechanical stress and is sensitive to mainly the ambient vacuum level. The average quality factors of the devices packaged under pressures of 50, 100, and 200 mTorr were 4987, 3415, and 2127, respectively. The results demonstrated the high controllability of the quality factor by vacuum adjustment. The mechanical robustness of the quality factor was confirmed by comparing the quality factors before and after high-temperature storage. Furthermore, through more than 50 days of monitoring, the stability of the quality factor was also certified.

온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정 (Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence)

  • 정운섭;김성욱;김호영;유정열
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.153-160
    • /
    • 2006
  • A technique for measuring surface temperature field in micro scale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.

Comparative Assessment of Diagnostic Performance of Cytochrome Oxidase Multiplex PCR and 18S rRNA Nested PCR

  • Kumari, Preeti;Sinha, Swati;Gahtori, Renuka;Quadiri, Afshana;Mahale, Paras;Savargaonkar, Deepali;Pande, Veena;Srivastava, Bina;Singh, Himmat;Anvikar, Anupkumar R
    • Parasites, Hosts and Diseases
    • /
    • 제60권4호
    • /
    • pp.295-299
    • /
    • 2022
  • Malaria elimination and control require prompt and accurate diagnosis for treatment plan. Since microscopy and rapid diagnostic test (RDT) are not sensitive particularly for diagnosing low parasitemia, highly sensitive diagnostic tools are required for accurate treatment. Molecular diagnosis of malaria is commonly carried out by nested polymerase chain reaction (PCR) targeting 18S rRNA gene, while this technique involves long turnaround time and multiple steps leading to false positive results. To overcome these drawbacks, we compared highly sensitive cytochrome oxidase gene-based single-step multiplex reaction with 18S rRNA nested PCR. Cytochrome oxidase (cox) genes of P. falciparum (cox-III) and P. vivax (cox-I) were compared with 18S rRNA gene nested PCR and microscopy. Cox gene multiplex PCR was found to be highly specific and sensitive, enhancing the detection limit of mixed infections. Cox gene multiplex PCR showed a sensitivity of 100% and a specificity of 97%. This approach can be used as an alternative diagnostic method as it offers higher diagnostic performance and is amenable to high throughput scaling up for a larger sample size at low cost.

A Dynamic Locality Sensitive Hashing Algorithm for Efficient Security Applications

  • Mohammad Y. Khanafseh;Ola M. Surakhi
    • International Journal of Computer Science & Network Security
    • /
    • 제24권5호
    • /
    • pp.79-88
    • /
    • 2024
  • The information retrieval domain deals with the retrieval of unstructured data such as text documents. Searching documents is a main component of the modern information retrieval system. Locality Sensitive Hashing (LSH) is one of the most popular methods used in searching for documents in a high-dimensional space. The main benefit of LSH is its theoretical guarantee of query accuracy in a multi-dimensional space. More enhancement can be achieved to LSH by adding a bit to its steps. In this paper, a new Dynamic Locality Sensitive Hashing (DLSH) algorithm is proposed as an improved version of the LSH algorithm, which relies on employing the hierarchal selection of LSH parameters (number of bands, number of shingles, and number of permutation lists) based on the similarity achieved by the algorithm to optimize searching accuracy and increasing its score. Using several tampered file structures, the technique was applied, and the performance is evaluated. In some circumstances, the accuracy of matching with DLSH exceeds 95% with the optimal parameter value selected for the number of bands, the number of shingles, and the number of permutations lists of the DLSH algorithm. The result makes DLSH algorithm suitable to be applied in many critical applications that depend on accurate searching such as forensics technology.