• Title/Summary/Keyword: High resolution computed tomography

Search Result 163, Processing Time 0.023 seconds

The prevalence of radix molaris in the mandibular first molars of a Saudi subpopulation based on cone-beam computed tomography

  • AL-Alawi, Hassan;Al-Nazhan, Saad;Al-Maflehi, Nassr;Aldosimani, Mazen A.;Zahid, Mohammed Nabil;Shihabi, Ghadeer N.
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.1
    • /
    • pp.1.1-1.9
    • /
    • 2020
  • Objectives: The purpose of this study was to determine the incidence of radix molaris (RM) (entomolaris and paramolaris) in the mandibular first permanent molars of a sample Saudi Arabian subpopulation using cone-beam computed tomography (CBCT). Materials and Methods: A total of 884 CBCT images of 427 male and 457 female Saudi citizens (age 16 to 70 years) were collected from the radiology department archives of 4 dental centers. A total of 450 CBCT images of 741 mature mandibular first molars that met the inclusion criteria were reviewed. The images were viewed at high resolution by 3 examiners and were analyzed with Planmeca Romexis software (version 5.2). Results: Thirty-three (4.5%) mandibular first permanent molars had RM, mostly on the distal side. The incidence of radix entomolaris (EM) was 4.3%, while that of radix paramolaris was 0.3%. The RM roots had one canal and occurred more unilaterally. No significant difference in root configuration was found between males and females (p > 0.05). Types I and III EM root canal configurations were most common, while type B was the only RP configuration observed. Conclusions: The incidence of RM in the mandibular first molars of this Saudi subpopulation was 4.5%. Identification of the supernumerary root can avoid missing the canal associated with the root during root canal treatment.

Optimization of Exposure Parameters in Brain Computed Tomography (두부 전산화단층촬영에서 노출 파라미터의 최적화)

  • Ko, Seong-Jin;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.355-362
    • /
    • 2010
  • This study determines a range of CT parameter values in Brain CT which are minimizing patient absorption dose without compromising the image quality and optimal exposure condition. We measured dose and image noise using conventional CT parameters in Brain CT. In additon, we evaluated dose, SNR and PSNR of head phantom images while changing kVp and rotation time. In this study, effectiveness of dose that was achieved from dose reproducible experiments in conventional head CT condition is determined by changing kVp and rotation time. Dose and PSNR is related to low dose-high resolution condition. In conclusion, we suggest that using proposed conditions is effective for imaging to compare with conditions proposed by the manufacturer.

Update in Diagnosis of Idiopathic Pulmonary Fibrosis and Interstitial Lung Abnormality (특발폐섬유증 진단의 최신 지견과 간질성폐이상)

  • Bo Da Nam;Jung Hwa Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.770-790
    • /
    • 2021
  • Idiopathic pulmonary fibrosis (IPF), based on the 2018 international clinical practice guidelines, can be diagnosed with a usual interstitial pneumonia (UIP) pattern on high-resolution computed tomography (HRCT) and compatible clinical findings. Given that imaging is pivotal for IPF evaluation and diagnosis, more emphasis should be placed on the integration of clinical, radiological, and pathologic findings for multidisciplinary diagnosis. Interstitial lung abnormality (ILA), on the other hand, has a purely radiological definition based on the incidental identification of CT abnormalities. Taken together, differentiation between ILA and clinically significant interstitial lung disease (ILD) must be based on proper clinical evaluation. With this review, the recent updates in IPF diagnosis and the radiologic considerations for ILA can be well understood, which can be helpful for the proper diagnosis and management of patients with diffuse interstitial pulmonary fibrosis.

The Correlation between the Radiological Changes and the Level of Transforming Growth Factor-β1 in Patients with Pulmonary Tuberculosis (폐결핵의 영상학적 진행과 Transforming Growth Factor-β1 농도와의 관련성)

  • Cho, Yongseon;Lee, Yang Deok;Cho, Wook;Na, Dong Jib;Han, Min Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.3
    • /
    • pp.297-303
    • /
    • 2006
  • Background : Pulmonary tuberculosis is frequently accompanied with complications such as bronchiectasis, cavities, fibrosis and a deterioration of the lung function. However, there is little information available on the pathogenesis of these complications in pulmonary tuberculosis. Among the many factors involving in tissue remodeling, transforming growth factor-${\beta}1$ ($TGF-{\beta}1$) is a potent stimulus of the extracellular matrix fomation and a mediator of potential relevance for airway wall remodeling. Therefore, this study examined the relationship between the radiological changes and the $TGF-{\beta}1$ level in patients with pulmonary tuberculosis. Methods : Serum and bronchoalveolar lavage fluid (BALF) were collected from total of 35 patients before treating them for active pulmonary tuberculosis, and the $TGF-{\beta}1$ levels were measured using an enzyme-linked immunosorbent assay (ELISA). The BALF levels were recalculated as the epithelial lining fluid (ELF) levels using the albumin method. pulmonary function test (PFT) and high resolution computed tomography (HRCT) were performed before and after treatment. Results : There was a strong correlation between the serum $TGF-{\beta}1$ level and the presence of cavities (r=0.404, p=0.006), even though the BAL $TGF-{\beta}1$ level showed a weak correlation with complications. In addition, there was no correlation between the $TGF-{\beta}1$ levels before treatment and the changes in the PFT and HRCT during treatment. Conclusion : There is a correlation between the serum $TGF-{\beta}1$ level and cavity formation in pulmonary tuberculosis before treatment. However, further study will be needed to confirm this.

Diagnostic Meaning of High Resolution Computed Tomography Compared with Chest Radiography for Screening of Welder's lung (용접공진폐증 집단검진을 위한 단순 흉부방사선 촬영과 고해상 흉부전산화 단층촬영의 진단적 의의)

  • Kang, J.H.;Chun, J.H.;Gu, H.W.;Ko, K.S.;Yu, B.C.;Sohn, H.S.;Lee, J.T.;Lee, C.U.;Kim, K.I.;Choi, S.J.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.853-861
    • /
    • 1996
  • Pneumoconiosis is one of the major problem in the field of occupational health at Korea. Therefore, the efficient diagnosis of pneumoconiosis is a hot issue on the occupational health program. The author executed this study to estimate the diagnostic value of high resolution computed tomography(HRCT) compared with chest radiography for screening of welder's lung. HRCT was introduced very recently for the diagnosis of pneumoconiosis, however, the diagnostic value for screening of welder's lung - principally nonfibrogenic and reversible - has not been evaluated. The subjects were fifty cases of welder's lung or suspected cases who had been collected between 1989 and 1994 from one shipyard and continuously followed-up on the basis of in-plant periodic health check program. We applied both chest radiography and HRCT on the same subjects from May 1 to 30, 1996. The images were evaluated by two careered radiologists independently. The findings of chest radiography were classified into four category by ILO classification, and the findings of HRCT according to the criteria of Bergin et al. The concordance between two radiologists expressed with Kendall's tau-b was 0.72 by chest radiography and 0.44 by HRCT- that is, interobserver variation of HRCT was bigger than that of chest radiography. The concordance between the two different methods was highly variable as 0.44 by radiologist A and 0.06 by radiologist B - that is, interobserver variation was very big. However, HRCT looked more detectable for the minor parenchymal change. These findings suggested that it is not appropriate to use HRCT routinely for screening of welder's lung due to lack of diagnostic criteria, and feasibility, acceptability and economic aspects. Nevertheless, HRCT might be recommendable in the case of equivocal parenchymal features on the chest radiography, unexplained respiratory symptoms, and/or lung function abnormalities suggestive of interstitial fibrosis.

  • PDF

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

A Case of Pulmonary Alveolar Proteinosis with Spontaneous Resolution (자연 소실된 폐포단백증 1예)

  • Nam, Seung Bum;Park, Kwang Young;Lee, Ho Jin;Jung, Jae Wook;Choi, Yoon Hee;Kim, Hyo Seok;Kim, Cheol Hyeon;Lee, Jae Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.3
    • /
    • pp.294-298
    • /
    • 2007
  • Pulmonary alveolar proteinosis is a rare disorder that is characterized by the abundant accumulation of surfactant-derived material within the alveolar spaces and distal bronchioles. Although the findings of homogenous ground-glass opacities overlaid by thickened septa, which form a "crazy paving" pattern on high-resolution computed tomography, can assist in making a diagnosis, a lung biopsy is usually required. This disorder has a variable clinical course, from spontaneous resolution to respiratory failure and death. While a whole lung lavage has been the standard treatment since the early 1960s, GM-CSF therapy has been attempted based on the recently suggested pathogenetic mechanism. We report a case of pulmonary alveolar proteinosis that resolved spontaneously after an open lung biopsy.

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

Automated Lung Segmentation on Chest Computed Tomography Images with Extensive Lung Parenchymal Abnormalities Using a Deep Neural Network

  • Seung-Jin Yoo;Soon Ho Yoon;Jong Hyuk Lee;Ki Hwan Kim;Hyoung In Choi;Sang Joon Park;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.476-488
    • /
    • 2021
  • Objective: We aimed to develop a deep neural network for segmenting lung parenchyma with extensive pathological conditions on non-contrast chest computed tomography (CT) images. Materials and Methods: Thin-section non-contrast chest CT images from 203 patients (115 males, 88 females; age range, 31-89 years) between January 2017 and May 2017 were included in the study, of which 150 cases had extensive lung parenchymal disease involving more than 40% of the parenchymal area. Parenchymal diseases included interstitial lung disease (ILD), emphysema, nontuberculous mycobacterial lung disease, tuberculous destroyed lung, pneumonia, lung cancer, and other diseases. Five experienced radiologists manually drew the margin of the lungs, slice by slice, on CT images. The dataset used to develop the network consisted of 157 cases for training, 20 cases for development, and 26 cases for internal validation. Two-dimensional (2D) U-Net and three-dimensional (3D) U-Net models were used for the task. The network was trained to segment the lung parenchyma as a whole and segment the right and left lung separately. The University Hospitals of Geneva ILD dataset, which contained high-resolution CT images of ILD, was used for external validation. Results: The Dice similarity coefficients for internal validation were 99.6 ± 0.3% (2D U-Net whole lung model), 99.5 ± 0.3% (2D U-Net separate lung model), 99.4 ± 0.5% (3D U-Net whole lung model), and 99.4 ± 0.5% (3D U-Net separate lung model). The Dice similarity coefficients for the external validation dataset were 98.4 ± 1.0% (2D U-Net whole lung model) and 98.4 ± 1.0% (2D U-Net separate lung model). In 31 cases, where the extent of ILD was larger than 75% of the lung parenchymal area, the Dice similarity coefficients were 97.9 ± 1.3% (2D U-Net whole lung model) and 98.0 ± 1.2% (2D U-Net separate lung model). Conclusion: The deep neural network achieved excellent performance in automatically delineating the boundaries of lung parenchyma with extensive pathological conditions on non-contrast chest CT images.

Assessment of Coronary Stenosis Using Coronary CT Angiography in Patients with High Calcium Scores: Current Limitations and Future Perspectives (높은 칼슘 점수를 가진 환자에서 관상동맥 CT 조영술을 이용한 협착 평가의 한계와 전망)

  • Doo Kyoung Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.270-296
    • /
    • 2024
  • Coronary CT angiography (CCTA) is recognized for its role as a gatekeeper for invasive coronary angiography in patients suspected of coronary artery disease because it can detect significant coronary stenosis with high accuracy. However, heavy plaque in the coronary artery makes it difficult to visualize the lumen, which can lead to errors in the interpretation of the CCTA results. This is primarily due to the limited spatial resolution of CT scanners, resulting in blooming artifacts caused by calcium. However, coronary stenosis with high calcium scores often requires evaluation using CCTA. Technological methods to overcome these limitations include the introduction of high-resolution CT scanners, the development of reconstruction techniques, and the subtraction technique. Methods to improve reading ability, such as the setting of appropriate window width and height, and evaluation of the position of calcified plaque and residual visibility of the lumen in cross-sectional images, are also recommended.