• Title/Summary/Keyword: High permeability

Search Result 1,381, Processing Time 0.036 seconds

Optimization for Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.5
    • /
    • pp.548-556
    • /
    • 2016
  • Recently, porous alumina-based ceramics have been extensively applied in the semi-conductor and display industries, because of their high mechanical strength, high chemical resistance, and high thermal resistance. However, the high electrical resistance of alumina-based ceramics has a negative effect in many applications due to the generation of static electricity. The low electrical resistance and high air permeability are key aspects in using porous alumina-based ceramics as vacuum chucks in the semi-conductor industry. In this study, we tailored the pore structure of porous alumina-based ceramics by adjusting the mixing ratio of the starting alumina, which has different particle sizes. And the electrical resistance was controlled by using chemical additives. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimetry, capillary flow porosimetry, a universal testing machine, X-ray diffraction, and a high-resistance meter.

Air Permeability of Softwoods Imported from the Russian Far East (북양(北洋) 침엽수재(針葉樹材)의 공기(空氣) 투과성(透過性))

  • Jee, Woo-Kuen;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.22-31
    • /
    • 1996
  • Air permeabilities for both sapwood and heartwood of the three softwoods(Picea jezoensis, Larix gmelini, Pinus sylvestris), imported from the Russian Far East, in the three different structural directions were measured using steady-state rotameter method. After measuring permeability, the liquid absorption into the longitudinal permeability specimens was measured, and then related with the measured permeability. The longitudinal permeability was overwhelmingly greater than the transverse permeability, with the radial direction showing higher permeability than the tangential direction. There appear to be species differences in permeability of the three softwoods. The mean longitudinal sapwood permeability of P. jezoensis(3.300darcy) and P. sylvestris(3.028darcy) were considerably greater(ca. 25times) than that of L. gmelini(0.134darcy). Also the average longitudinal heartwood permeability of P. jezoensis(0.300darcy) was about 10 times as great as that of P. sylvestris(0.029darcy) and L. gmelini(0.024darcy). The average calculated radius of pit openings in the heartwood was $0.101{\mu}m$ for L. gmelini, $0.152{\mu}m$ for P. sylvestris for and $0.703{\mu}m$ for P. jezoensis. Heartwood permeability increases with the increase in radius of pit pore and the decrease in ring width and in extractive content, even though the correlation between permeability and its affecting factors was dependent on species. However, there was an inverse relationship between specific gravity and permeability, showing poor correlation between them. The correlation between air permeability and liquid retention was fairly high, so it was revealed that prediction of liquid absorption into the wood by using permeability was feasible.

  • PDF

The Permeability Characteristics of the Reactive Soil - Bentonite Landfill Liner (혼합반응 차수재의 투수특성 연구)

  • 이강원;황의석;안기봉;정하익;김학문
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.545-552
    • /
    • 2002
  • The purpose of this paper is to investigate permeability characteristic of soil-bentonite landfill liner and development of desirable liner system. In this study, permeability tests for soil-bentonite, reactive soil-bentonite and apply bentomat and reactive mat are carried out under the low and high water pressure. According to test result, additional amount of bentonite decreases the coefficient of permeability up to the bentonite mixture ratio of 15%. Therefore, the permeability test for landfill liner's indicated that the use of general water would be in more safe side because the liner system show low permeability duet decrease effect of porous by suspended soild(SS). The permeability of leachate for Zeolite mixture ratio 0, 5, 10% with bentonite mixture ratio 15% showed negligible variation in the permeability with general water. Therefore, Zeolite could be used as a successful that is available purification material for the treatment of leachate, without changing the of landfill liners. Also odious smell could be removed by adding smell amount of Zeolite to the leachate. It was revealed that the bentomat and reactive mat installed in soil-bentonite layer effectively improved the permeability as well as purification of the leachate.

  • PDF

Comparison of Gastrointestinal Permeability of Caffeine, Propranolol, Atenolol, Ofloxacin, and Quinidine Measured Using Ussing Chamber System and Caco-2 Cell Monolayer

  • Song, Im-Sook;Choi, Young A;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.34-38
    • /
    • 2017
  • The purpose of this study was to develop a cocktail approach for the measurement of the permeability of marker compounds, caffeine and propranolol (high permeability), ofloxacin (intermediate), atenolol (low), and quinidine (P-glycoprotein substrate), simultaneously. Then we compared the permeability in Caco-2 cells with that in rat intestinal segments. The difference between individual measurement and cocktail approach was less than 20 %, and the permeabilities of these compounds were similar to those previously reported, suggesting that the cocktail transport study and simultaneous drug analysis were successfully developed and validated in this study. Additionally, in the application of this cocktail method, the permeability of five drugs in rat jejunum was similar to that in ileum but different from that in colon, which was measured using the Ussing chamber system. Moreover, permeability in jejunum and ileum was similar to that in Caco-2 cells. In conclusion, the permeability in Caco-2 cells was equivalent to the permeability in rat jejunum and ileum determined with the Ussing system. Therefore, this newly developed cocktail assay and its application to the Ussing system can be a useful tool for robust and rapid screening for site-specific permeability in rat intestine, thus accelerating the prediction of absorption of new chemical entities.

Mix Design for Pervious Recycled Aggregate Concrete

  • Sriravindrarajah, Rasiah;Wang, Neo Derek Huai;Ervin, Lai Jian Wen
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.239-246
    • /
    • 2012
  • Pervious concrete is a tailored-property concrete with high water permeability which allow the passage of water to flow through easily through the existing interconnected large pore structure. This paper reports the results of an experimental investigation into the development of pervious concrete with reduced cement content and recycled concrete aggregate for sustainable permeable pavement construction. High fineness ground granulated blast furnace slag was used to replace up to 70 % cement by weight. The properties of the pervious concrete were evaluated by determining the compressive strength at 7 and 28 days, void content and water permeability under falling head. The compressive strength of pervious concrete increased with a reduction in the maximum aggregate size from 20 to 13 mm. The relationship between 28-day compressive strength and porosity for pervious concrete was adversely affected by the use of recycled concrete aggregate instead of natural aggregate. However, the binder materials type, age, aggregate size and test specimen shape had marginal effect on the strength-porosity relationship. The results also showed that the water permeability of pervious concrete is primarily influenced by the porosity and not affected by the use of recycled concrete aggregate in place of natural aggregate. The empirical inter-relationships developed among porosity, compressive strength and water permeability could be used in the mix design of pervious concrete with either natural or recycled concrete aggregates to meet the specification requirements of compressive strength and water permeability.

Origin of the Initial Permeabiliy of Ni0.8-xZn0.2CoxFe2O4+δ Ferrite (Ni0.8-xZn0.2CoxFe2O4+δ조성 페라이트의 투자율 변화 기구)

  • 안용운;김종령;오영우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • The cause for the variation of the initial permeability according to the Co substitution of Ni-Zn ferrite used in the LC resonance filter for the power line communication is studied. The initial permeability decreases as the quantity of Co diminishes, and the saturation magnetization increases as the quantity increases. Because the sintering density and the microstructure of ferrite show little change, the variation of the initial permeability can't be explained by the density, microstructure nor the saturation magnetization factor. The magnetocrystalline anisotropy increases, similar with the saturation magnetization, as the quantity of Co increases. The increase of magnetocrystalline anisotropy value makes the domain wall energy grow, which leads to the decrease of the initial permeability, because there's linear law between the magnetocrystalline anisotropy and the domain wall energy. The resonance frequency to Co substitution moved to high frequency band, due to the close relationship with domain wall energy, Initial permeability decreaed a little with an increase of Co contents, but resonace frequency moved to high frequency band. as a result of that, when Co was added 0.05 mol, initial permeability and resonace frequency was 75 and 25 MHz respectively.

Effect of Fabric Structural Parameters and Surface Finishing Characteristics to Water Repellency/Proofing/Vapor Permeability of Breathable Fabrics for Sportswear Clothing (직물 구조인자와 표면 가공특성이 스포츠 의류용 투습직물의 발수/방수/투습특성에 미치는 영향)

  • Kim, Hyun Ah
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.112-118
    • /
    • 2020
  • This paper examined the water repellency, water proofing and water vapor permeability of twelve types of woven fabrics for sports wear clothing. Their physical properties were compared and discussed with the fabric structural parameters and surface finishing effect. A water repellent property of 100% was obtained in the coated or laminated water repellent finished fabrics; in addition, cotton/nylon breathable composite fabrics treated with a laminated finishing and with low fabric density showed a 90% water repellency. Water proofing fabric above 6,000 mm H2O hydraulic pressure was achieved by coated or laminated finishing; however, high density fabric or medium-level coated fabrics exhibited 100% water repellent and low water proofing characteristics. Superior water vapor permeability characteristics with good water repellency and proofing properties were achieved at the 2.5 layered low density and with 0.7 - 0.9 cover factor nylon fabrics treated with hydrophilic laminated finishing. The regression analysis for examining the effects of fabric structural parameters and surface finishing such as coating and laminating to the water vapor permeability exhibited a high determination coefficient of fabric structural parameters of 63.5%; in addition,, main factors among fabric structural parameters appeared to be cover factor and fabric thickness per weight. Coating and Laminating factors exhibited determination coefficient of water vapor permeability parameters of 36.5%.

Control of Electromagnetic Properties of High Initial Permeability Mn-Zn Ferrite with the Microstructure Control (미세구조 조절에 의한 고투자율 Mn-Zn Ferrite의 특성제어)

  • 도세욱;류지태;김정희;강태현;허원도
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.50-54
    • /
    • 1998
  • In order to obtain desired electromagnetic propertieι high initial permeability and good frequency dependance of initial p permeability, the adding effects of sevral seeds were experimented in Mn-Zn ferrite system. As adding seed grams, calcined at sintering temperature, abnormal grains were disappeared clearly but the density and the initial permcability of sintered Mn-Zn ferrite body were decreased. On the contrary, in case of adding seed rains which were calcined below the calcination temperatnre of matrix particle, abnormal grains remained but the initial permeability was increas$\xi$d with proper s$\xi$ed content. W With proper seed content, the initial permeability was increased by 10-20% but tbe $\alpha$ltoff frequency was not changed.

  • PDF

Improvement of bond strength and durability of concrete incorporating high volumes of class F fly ash

  • Wu, Chung-Hao;Chen, Chien-Jung;Lin, Yu-Feng;Lin, Shu-Ken
    • Advances in concrete construction
    • /
    • v.12 no.5
    • /
    • pp.367-375
    • /
    • 2021
  • This study experimentally investigated the improvement of bond strength and durability of concrete containing high volume fly ash. Concrete mixtures made with 0%, 25% and 60% replacement of cement with class F fly ash were prepared. Water-binder ratios ranged from 0.28 to 0.72. The compressive, flexural and pullout bond strength, the resistance to chloride-ion penetration, and the water permeability of concrete were measured and presented. Test results indicate that except for the concretes at early ages, the mechanical properties, bond strength, and the durability-related chloride-ion permeability and water permeability of concrete containing high volume (60% cement replacement) fly ash were obviously superior to the concrete without fly ash at later ages of beyond 56 days. The enhanced bond strength for the high volume fly-ash concrete either with or without steel confinement is a significant finding which might be valuable for the structural application.

Effects of processing conditions of sea tangle (Laminaria spp.) alginate film on permeability of ester compounds (에스테르 화합물의 투과율에 영향을 미치는 다시마 Alginate 필름의 가공조건)

  • YOU Byeong-Jin;SHIM Jae-Man
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.2
    • /
    • pp.143-147
    • /
    • 2000
  • The effects of alginate extracting conditions from sea tangle and the effects of film preparation conditions on the physical properties of the alginate film were investigated by measuring ester compounds permeability. The higher concentration of sodium carbonate solution as extracting solvent made the higher ethyl acetate permeability of alginate film, but extracting time showed little efficacy of alginate film permeability. The higher concentration of sorbitol as a plasticizer showed higher ethyl acetate permeability of alginate film, Adding various plasticizers, the ethyl acetate permeability of algiante films was increased in order as follow : sorbitol, glycerol and polyethylene glycol. Ester compounds haying the lower molecular weight showed the higher permeability. And the higher temperature made the ethyl acetate permeability of algiante film to be high.

  • PDF