• Title/Summary/Keyword: High permeability

Search Result 1,386, Processing Time 0.033 seconds

Development of Assay Methods for Enterotoxin of Escherichia coli Employing the Hybridoma Technology (잡종세포종기법을 이용한 대장균의 장독소 측정법 개발)

  • Kim, Moon-Kyo;Cho, Myung-Je;Park, Kyung-Hee;Lee, Woo-Kon;Kim, Yoon-Won;Choi, Myung-Sik;Park, Joong-Soo;Cha, Chang-Yong;Chang, Woo-Hyun;Chung, Hong-Keun
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.1
    • /
    • pp.151-161
    • /
    • 1986
  • In order to develop sensitive and sepcific assay methods for E. coli heat labile enterotoxin(LT) hybridoma cell lines secreting LT specific monoclonal antibody were obtained. LT was purified from cell lysate of E. coli O15H11. The steps included disruption of bacteria by French pressure, DEAE Sephacel ion exchange chromatography, Sephadex G200 gel filtration, and second DEAE Sephacel ion exchange chromatography, successively. Spleen cells from Balb/c mice immunized with the purified LT and $HGPRT^{(-)}$ plasmacytomas, $P3{\times}63Ag8.V653$ were mixed and fused by 50% (w/v) PEG. Hybrid cells were grown in 308 wells out of 360 wells, and 13 wells out of them secreted antibodies reacting to LT. Among these hybridoma cell 1G8-1D1 cell line was selected since it had produced high-titered monoclonal antibody continuously. By using culture supernatant and ascites from 1G8-1D1 cells the monoclonal antibody was characterized, and an assay system for detecting enterotoxigenic E. coli was established by double sandwich enzyme-linked immunosorbent assay (ELISA). The following results were obtained. 1. Antibody titers of culture supernatant and ascites from 1G8-1D1 hybridoma cells were 512, and 102, 400, respectively by GM1-ELISA and its immunoglobulin class was IgM. 2. The maximum absorption ratio of 1G8-1D1 cell culture supernatant to LT was 90% at $300\;{\mu}g/ml$ of LT concentration. LT concentration shown at 50% absorption ratio was $103.45{\mu}g$ and the absorption ratio was decreased with tile reduction of LT concentration. This result suggests that monoclonal antibody from 1G8-1D1 hybridoma cell bound with LT specifically. 3. The reactivities of 1G8-1D1 cell culture supernatant to LT and V. cholerae enterotoxin(CT) were 0.886 and 0.142(O.D. at 492nm) measured by the GM1-ELISA, indicating 1G8-1D1 monoclonal antibody reacted specifically with LT but not with CT. 4. The addition of 0.1ml of ascites to 0.6mg and 0.12mg of LT decreased the vascular permeability factor to 41% and 44% respectively, but it did not completely neutralize LT. 5. By double sandwich ELISA using monoclonal antibody, as little as 75ng of the purified LT per ml could be detected. 6. The results by assay of detecting LT in culture supernatants of 14 wild strains E. coli isolated from diarrhea patients by the double sandwich ELISA were almost the same level as those by reverse passive latex agglutination.

  • PDF

Studies on the Effect of the Thickness of Lining on Water Holding Capacity and Lield in Rice Patty with High Permeability (누수유에 있어서 밑다짐 두께의 차이가 보수력 및 수호량에 미치는 영향)

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1598-1603
    • /
    • 1969
  • A field expeperiment has been conducted in order to explore possibilities of efficient and economical irrigation methods for the rice cultivation through which irrigation water may be saved and rice paddies may keep water for longer period of time, resulting in an increased yield of rice. Some of the major findings from the experimentation are summarized in the following. 1. There is slightly significant difference among experimental plots in the weight of rice straw. 2. The 9cm-lined plot proves to be the best in terms of the thickness. In this connection, however, it seems to by 3cm. 3. The wheat straw-lined plot is found superior in yield. However, this may be resulted in by the application of more fertilizer, and how long the plot could be durable may be problematic. Since every two or three years the straw-lining work has to be done, more labour may be required of the plot. 4. It would be inappropriate to expect any meaningful experimental results for the first year, since surface soil and deep soil are mixed up in the course of work. There is not observed any meaningful difference in the number of ears per stalk and in the number of grains per ear. However, in the lined plots, the number of tillers is slightly increased. 5. Irrigation has been applied by means of ordinary method after lining. When irrigation is applied at the interval of five to six days, irrigation water is saved by 44.9 per cent in the case of 9cm-lined plot, 39.7 per cent in the case of 6 cm-lined plot, and 36.3 percent in the case of 3 cm-lined plot. 6. An increased yields arenoted in the wheat straw-lined plot by 23.8 per cent, in the 9 cm-lined plot by 20.1 per cent, in the 3 cm-lined plot by 12 per cent. and in the case of vinyl-lined plot by 12.5 per cent. 7. The rate of maturity of grains is proved better, and the husking rate also found better(75%), that is, the quality of rice grains is improved.

  • PDF

Classification of Hydrologic Soil Groups of Soil Originated from Limestone by Assessing the Rates of Infiltration and Percolation (석회암 유래 토양의 침투 및 투수속도 평가에 따른 수문유형 분류)

  • Hur, Seung-Oh;Jung, Kang-Ho;Sonn, Yeon-Kyu;Ha, Sang-Keun;Kim, Jeong-Gyu;Kim, Nam-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2009
  • Soils originated from limestone, located at the southern part of Kangwon province and Jecheon, Danyang of Chungbuk province are mainly composed of fine texture, and have different properties from soils originated from granite and granite gneiss, especially for water movement. This study was conducted for classification of hydrologic soil group (HSG) of soils originated from limestone by measuring the infiltration rate of surface soils and percolation rate of sub soils. Soils used for the experiment were 6 soils in total : Gwarim, Mosan, Jangseong, Maji, Anmi and Pyongan series. Infiltration and percolation rate were measured by a disc tension infiltrometer and a Guelph permeameter, respectively. Particle size distribution and organic matter content of the soils were analyzed. HSG, which was made by USDA NRCS(National Resources Conservation Service) for hydrology, of Gwarim series with O horizon of accumulated organic matter was classified as type A which show the properties of low runoff potential, rapid infiltration and percolation rate. HSG of Mosan series, which has high gravel content and very rapid permeability, was classified as type B/D because of the impermaeble base rock layer under 50cm from surface. HSG of Jangseong series with shallow soil depth was classified as type C/D owing to the impermaeble base rock layer under 50cm from surface. HSG of Maji series was type B, and HSG of Anmi series used as paddy land was type D because of slow infiltration and percolation rate caused by the disturbance of surface soil by puddling. HSG of Pyeongan series having a sudden change of layer in soil texture was type D because of the slow percolation rate caused a the layer.

The effect of air quality and humidity on aged characteristics of beeswax-treated paper during artificial aging (인공열화 시 공기질 및 습도가 밀랍지의 열화에 미치는 영향)

  • Yang, Eun Jeong;Choi, Kyoung Hwa;Kang, Yeong Seok;Cho, Jung hye;Jeong, Hye Young
    • 보존과학연구
    • /
    • s.33
    • /
    • pp.45-55
    • /
    • 2012
  • A beeswax-treated paper has no air permeability but has the water repellency compared with a general Hanji. Because of these properties, the differences of the aging factors and mechanisms between the outer partition of beeswax-treated paper that is affected by the surrounding conservation environment and the inner partition of it that is not affected are bigger than general books. In this research, we analyzed and compared the aging characteristics through the accelerated aging of the beeswax-treated paper by some air and humidity conditions. The results of the physical and optical analysis after the artificial aging, it was shown that the oxygen accelerates the aging of the beeswax-treated paper and the condition with the humidity 50% RH is more stable than the condition with the humidity 0% RH. The results of the CG/MS analysis that was conducted to figure out the decomposition charateristics of the beeswax according to the air quality and the humidity, a low molecular weight compound that the number of carbon is C9-C20 including a fatty acid such as a palmitic acid was increased as the aging was progressed. However, under the same environment, a compound that the number of carbon is C21-C36 including a hydrocarbon and a aliphatic alcohol and a high molecular weight compound that the number of carbon is more than C34 including a wax ester were decreased. A rate of change according to the air quality and the humidity was similar to the beeswax-treated papers.

  • PDF

Studies on Wet Paddy Field Underdrainage Improvement in the Gum-Ho Area (I) (금호지구 저습답의 암거배수효과에 관한 연구(I))

  • 김조웅;김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.4
    • /
    • pp.82-95
    • /
    • 1980
  • This paper complies the results of the studies so far made on the subsoil improvement of subsurface drainage systems for wet paddy fields (those were located in the Gum-Ho area in Kyung Buk province) which had poor permeability and a high water table. In general, a drainage problem is an excess of water on the ground surface which can effect the productivity and bearing capacity of the soil. With drain pipe systems, (According to their depths and spacing) it may be possible to correct that problem. The experimentation consisted of three test plots, two of which included drain pipe systems with varing depths and width spacing of the pipes. The third plot (C) was an ordinary plot being exempt of a drain pipe system. In detail, the depth of plot A was 80 cm, and the width spacings began at 2. Om and increased by 2. Om up to 10. 0m. The depth of plot B was 60cm and the width spacing was the same as plot A. These tests were performed to research specific details; such as crop yeild, bearing capacity of the soil, the amount of underdrainage, surface cracks, root distribution, the water table level, the consumptive water depth and the soil moisture content. The test period lasted three years, from 1977 thru 1979. The results obtained were as follows: 1. During the test period, the weather conditions for the area tested were in accordance with the annual average for that area. Furthermore the precipitation factor during the spring cultivation season, the intermediate drainage period and the harvest drainage period was of optimum conditions for controling surface cracks, because of less precipitation than evaporation. 2. The difference in the level of the ground water table in plots A and B was hardly noticable, but the difference in the test plots and the ord. plot was greatly noticable. The test plots (A, B) were 30 to 40cm lower than the ordinary plot. On the whole, the ground water table of the ord. plot always stayed at a level of 15-20cm beneath the surface of the soil, the ground water table of the test plot A showed The difference in the depth of the pipe lower than the test plot B, while the test plots showed a remarkable descending effect. 3. The soil temperature in plot A was slightly core than in plot B with a difference of 0. 47$^{\circ}$C, but plot A was 1. 6$^{\circ}$C higher than the ord. plot during the flooding period, but after drainage the temperature difference climed to 2. 0$^{\circ}$C. 4. During the 3rd test year, the values of the cracks were recorded with the values of 59cm in plot A, 42cm in plot B and 15cm in the ordinary plot. Plots A and B had increased 2.5 times the value of the first year while the ordinary plot had remained the same. 5. The root weight of the rice was measured at a value of 77.2 gr. for plot A, 73.5 gr. for plot B and 65.3 gr. for the ord. plot. Therefore, the root growths in plots A and B were much more energetic than in the ord. plot. 6. The consumptive water depth measured during the 3rd year resulted in the values of 26. 0mm per day for plot A, and 24.9 mm per day for plot B, respectively. Therefore, both plot A and plot B maintained the optimum consumptive water depths, but the ordinary plot only obtained the value of 12.3 mm per day, which clearly showed less than the optimum consumptive water depth which is 20 to 30 mm/day. 7. The soil moisture content is in direct relationship to the ground water level. During drainage, test plot A decreased in its ground water level much more rapidly than the other two plots. Therefore, plot A had a much less soil moisture content. But this decreased water level could be directly effected by the weather conditions. 8. The relationship between the bearing capacity and the soil moisture content were directly inversely proportional. It can be assumed that the occurence of soil creaks is limited by the soil moisture content. Therefore, the greater the progress of the surface creaks resulted in a greater bearing capacity. So, tast plot A with a greater amount of surface cracks than the other test plots resulted in a greater bearing capacity. But, the bearing capacity at the harvest season could be effected by the drainage during the intermediate drainage period and by the weather conditions. 9. Comparing the production of the test plots to the ord. plot; there was an increased value of 840kg for plot A, 755kg for plot B and 695kg for the ord. plot in the rough rice. Therefore, plot A had an increase of 20% over the ordinary plot. The possibility of producing double crops was investigated. The effects on barley production in the test plots showed a value of 367kg per 10 acres, which substantiated the possibility of double crops because that value showed an increased value over the average yearly yield for those uplands. 10. So as a result, it can be recommended that by including a drain pipe system with the optimum conditions of an (80cm centimeter) depth and a (l0m) spacing will have a definite positive effect on the over all production capacity and quality of wetpaddy fields.

  • PDF

Dysfunction of Autonomic Nervous System in Patients with Chronic Obstructive Pulmonary Diseases (만성 폐쇄성 폐질환 환자의 자율신경 장애)

  • Shin, Kyeong-Cheol;Lee, Kwan-Ho;Park, Hye-Jung;Shin, Chang-Jin;Lee, Choong-Ki;Chung, Jin-Hong;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.317-326
    • /
    • 1999
  • Background: Neural control of airway function is through parasympathetic, sympathetic and non-adrenergic, non-cholinergic mechanisms. The autonomic nervous system controls the airway smooth muscle tone, mucociliary system, permeability and blood flow in the bronchial circulation and release of mediators from the mast cells and other inflammatory cells. The cardiovascular and respiratory autonomic efferent fibers have a common central origin, so altered cardiovascular autonomic reflexes could reflect the altered respiratory autonomic status. Therefore, we performed this study to assess the autonomic abnormality and determine the correlating factors of severity of autonomic neuropathy in patients with chronic obstructive pulmonary disease(COPD) using easily reproducible cardiovascular autonomic reflex function test. Method: The study included 20 patients with COPD and 20 healthy persons obtained on Health Promotion Center in Yeungnam university hospital. All the patients had history and clinical features of COPD as defined by the American Thoracic Society. Any patients with myocardial ischemia, cardiac arrythmia, hypertension, central or peripheral nervous system disease, diabetes mellitus, or any other diseases known to produce autonomic neuropathy, has excluded. The autonomic nervous system function tests included three tests evaluating the parasympathetic system and two tests evaluating the sympathetic system. And also all subjects were subjected to pulmonary function test and arterial blood gas analysis. Results: Autonomic dysfunction was more commonly associated with patients with COPD than healthy person The parasympathetic dysfunction was frequent in patient with COPD, but sympathetic dysfunction seemed preserved. The severity of parasympathetic dysfunction in patients with COPD was correlated with the degree of duration of disease, smoking, reductions in the value of $FEV_1$ and FVC, and arterial hypoxemia but no such correlation existed for age, type of COPD, $FEV_1$/FVC, or $PaCO_s$. Conclusion: There is high frequency of parasympathetic dysfunction associated with COPD and the parasympathetic abnormality in COPD is increased in proportion to severity of airway disease. In COPD, parasympathetic dysfunction probably does not the cause of disease, but it may be an effect of disease progression.

  • PDF

The Effect of Chemical Composition and Sintering Temperature on The Improvement of Physical Properties of Mn-Zn Ferrites (Mn-Zn ferrite의 성분 및 소결 온도에 따른 물리적 특성의 향상 연구)

  • 고재귀
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.4
    • /
    • pp.269-274
    • /
    • 1995
  • The basic composition of Mn-Zn ferrite was $Mn_{0.631}Zn_{0.316}Fe_{2.053}O_{4}$(specimen A), $Mn_{0.584}Zn_{0.312}Fe_{2.104}O_{4}$(specimen B) and $Mn_{0.538}Zn_{0.308}Fe_{2.154}O_{4}$(specimen C) with additional 0.1 mol % $CaCo_{3}$ and 0.04 mol % $V_{2}O_{5}$. For high per¬meability and acceleration of grain growth, $CaCo_{3}$ and $V_{2}O_{5}$. was added. The mixture of the law materials was calcinated at $950^{\circ}C$ for 3 hours and then milled. The compacts of toroidal type were sintered at different temperature($1250^{\circ}C$, $1300^{\circ}C$, $1350^{\circ}C$) for 2 hours in $N_2$ atmosphere. The effects of the various raw material composition and sintered temperature on the physical properties of Mn-Zn ferrite have been investigated. They turned out to be spinel structure by X-ray diffraction and the size of grain from SEM was from $18\;\mu\textrm{m}\;to\;23\;\mu\textrm{m}$. As the sintering temperature was increased from $1250^{\circ}C$ to $1350^{\circ}C$, the initial permeability and magnetic induction has increased and the both of Q factor and coercive force has decreased. The coercive force and curie temperature were almost the same at each specimen Their values were about 0.45 Oe and $200^{\circ}C$. The frequency of specimen will used in the range from 200 kHz to 2 MHz. The basic composition of $Mn_{0.584}Zn_{0.312}Fe_{2.104}O_{4}$(specimen B) sintered at $1300^{\circ}C$ shows the best results at magnetic induction (Br & Bm).

  • PDF

Extraction of Carotenoid from Phaffia rhodozyma by Combining Permeabilizing Methods and Pulsed Electric Fields Treatments (투과성 증진 방법과 펄스전기장의 병합처리에 의한 Phaffia rhodozyma로부터의 Carotenoid 추출)

  • Kim, Nam-Hoon;Shin, Jung-Kue;Lee, Seok-Hoon;Cho, Hyung-Yong;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1529-1535
    • /
    • 1999
  • This study was done for the extraction of carotenoid from Phaffia rhodozyma in combination with PEF and other methods. PEF treatment conditions were $30{\sim}80\;kV/cm,\;100{\sim}1000\;Hz\;and\;100{\sim}1000\;{\mu}s$. In order to increase permeability of yeast cell wall, various methods such as freezing-thawing, mechanical treatment, solvents, permeabilizing agents, and yeast cell wall lytic enzyme were used before PEF treatment. The combination of PEF $(50\;kV/cm,\;300\;Hz,\;1000\;{\mu}s)$ and conventional methods such as solvent and freezing-thawing pre-treatment had no effects on the extraction of carotenoid pigments. The extent of extracted carotenoid by the PEF $treatment(50\;kV/cm,\;300\;Hz,\;1000\;{\mu}s)$ combined with yeast cell wall lytic enzyme and mechanical pre-treatment increased 52% and 69.8% more than the sum of that by each treatment, respectively. Permeabilizing agents, especially Tween 20 and capric acid, enhanced the extraction efficiency of carotenoid pigments from P. rhodozyma cells. These results indicated the feasibility for the continuous extracting carotenoid pigments from P. rhodozyma by PEF combined with other permeabilizing methods.

  • PDF

A Case study and Analysis on the Up-Lift Pressure Treatment Evaluation of Underground Installations for their Efficient Adoption (사례분석을 통한 효율적 상향수압(Up-Lift Pressure) 처리공법 적용방안에 관한연구 - ◯◯ 상업지역 현장사례 중심으로 -)

  • Ko, Ok-Yeol;Kwon, Oh-Chul;Shim, Jae-Kwang;Park, Tae-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.119-129
    • /
    • 2009
  • Building construction trends have been changed dramatically in terms of size and mass. With the need to maximize land usage, there has been an increase in the construction of high-rise buildings. This affects not only the entire construction duration and cost, but also subsequent construction activities, such as work to increase underground facilities and in reclamation land area construction. These types of site conditions require soft ground reinforcement and the proper uplift water pressure treatment. In general, two kinds of methods have been used for uplift water pressure treatment systems. However, there have been some problems arising as the result of a lack of research and analysis on underground construction techniques, and a reliance on experiments over actual survey and analysis of site conditions. This paper focused on the problems of conventional selection procedure, by analyzing drawings and proposing a kind of modeling for a reasonable procedure. The results were applied to OO project as a sample construction case to be verified in this research. The initial plan in the case project was the Rock Anchor System. However, as there were terrible miscalculations of basic site conditions that had an extraordinary influence on the underground water level, such as the site's proximity to the Han-river, it was necessary to change the plan to include apermanent drainage system. This achieved a direct construction cost reduction \ 406,702,000 and a maximum sayings of 4% of operational cost, based on the 50-year building Life Cycle Cost.

Study on Production Performance of Shale Gas Reservoir using Production Data Analysis (생산자료 분석기법을 이용한 셰일가스정 생산거동 연구)

  • Lee, Sun-Min;Jung, Ji-Hun;Sin, Chang-Hoon;Kwon, Sun-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.58-69
    • /
    • 2013
  • This paper presents production data analysis for two production wells located in the shale gas field, Canada, with the proper analysis method according to each production performance characteristics. In the case A production well, the analysis was performed by applying both time and superposition time because the production history has high variation. Firstly, the flow regimes were classified with a log-log plot, and as a result, only the transient flow was appeared. Then the area of simulated reservoir volume (SRV) analyzed based on flowing material balance plot was calculated to 180 acres of time, and 240 acres of superposition time. And the original gas in place (OGIP) also was estimated to 15, 20 Bscf, respectively. However, as the area of SRV was not analyzed with the boundary dominated flow data, it was regarded as the minimum one. Therefore, the production forecasting was conducted according to variation of b exponent and the area of SRV. As a result, estimated ultimate recovery (EUR) increased 1.2 and 1.4 times respectively depending on b exponent, which was 0.5 and 1. In addition, as the area of SRV increased from 240 to 360 acres, EUR increased 1.3 times. In the case B production well, the formation compressibility and permeability depending on the overburden were applied to the analysis of the overpressured reservoir. In comparison of the case that applied geomechanical factors and the case that did not, the area of SRV was increased 1.4 times, OGIP was increased 1.5 times respectively. As a result of analysis, the prediction of future productivity including OGIP and EUR may be quite different depending on the analysis method. Thus, it was found that proper analysis methods, such as pseudo-time, superposition time, geomechanical factors, need to be applied depending on the production data to gain accurate results.