• 제목/요약/키워드: High performance and Energy consumption

검색결과 535건 처리시간 0.026초

소형 어선용 디젤기관에서의 연료유 성상에 따른 배기배출물 특성에 관한 연구 (An experimental study on characteristics of exhaust emissions with fuel properties changes in a diesel engine for small-sized fishing vessel)

  • 서정주;왕우경;김상암
    • 수산해양기술연구
    • /
    • 제46권4호
    • /
    • pp.487-494
    • /
    • 2010
  • In order to test the applicability of bunker-A in a diesel engine for small-fishing boat, the investigation of the engine performance and the exhaust emission was performed under various conditions of fuel property, intake air pressure and fuel temperature. It was also performed based on IMO NOx Technical code. At high load, the energy consumption rate of bunker-A was lower than that of diesel oil, and the characteristics of exhaust emission of bunker-A were similar to those, and NOx emission rates of both fuels satisfied the IMO NOx emission regulation limits. The energy consumption rate and characteristics of exhaust emission were improved as the intake air pressure was increased, but these were not improved remarkably as the temperature of bunker-A was heated. However, at low load the energy consumption rate, CO emission rate and HC emission rate of bunker-A were higher than those of diesel oil, but NOx emission rates of the fuels were about the same. In addition, at low load the energy consumption rate and CO emission rate of bunker-A were increased as the intake air pressure and the temperature were higher than normal conditions. Accordingly, it is thought that the use of bunker-A in a kind of test engine is possible at high load. On the other hand, it is thought that more research is needed to improve the combustion efficiency under low temperature and low load condition.

MRAM 기반 SSD 파일 시스템의 에너지 효율적 서브페이징 (Energy-Efficient Subpaging for the MRAM-based SSD File System)

  • 이재열;한재일;김영만
    • 한국IT서비스학회지
    • /
    • 제12권4호
    • /
    • pp.369-380
    • /
    • 2013
  • The advent of the state-of-the-art technologies such as cloud computing and big data processing stimulates the provision of various new IT services, which implies that more servers are required to support them. However, the need for more servers will lead to more energy consumption and the efficient use of energy in the computing environment will become more important. The next generation nonvolatile RAM has many desirable features such as byte addressability, low access latency, high density and low energy consumption. There are many approaches to adopt them especially in the area of the file system involving storage devices, but their focus lies on the improvement of system performance, not on energy reduction. This paper suggests a novel approach for energy reduction in which the MRAM-based SSD is utilized as a storage device instead of the hard disk and a downsized page is adopted instead of the 4KB page that is the size of a page in the ordinary file system. The simulation results show that energy efficiency of a new approach is very effective in case of accessing the small number of bytes and is improved up to 128 times better than that of NAND Flash memory.

실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가 (Annual Energy Performance Evaluation of Zero Energy House Using Metering Data)

  • 임희원;윤종호;신우철
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Comparative Study on a Single Energy Recovery Circuits for Plasma Display Panels (PDPs)

  • Yi, Kang-Hyun;Choi, Seong-Wook;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2007
  • Comparative study on a low cost sustaining driver with single and dual path energy recovery circuits for plasma display panels (PDPs) is shown in this paper. The cost of PDPs has been still high and about half of the cost has been occupied by driving circuit. A simple sustaining driver is proposed to reduce the cost and size of driving circuit. The proposed driver has small number of devices and reactive components and there are two methods for charging and discharging PDPs such as single and dual path energy recovery circuits. A comparative research on two-types of energy recovery path is practiced to evaluate performance. As a result, the dual energy recovery path circuit has low power consumption, low surge current and high performance. To verify those results, experiment will be shown with 42-inch HD panel.

  • PDF

밸브 타이밍 지각과 과급에 의한 흡기관 분사식 수소기관의 고성능 실현 (The Realization of High Performance in a Hydrogen-Fueled Engine with External Mixture by Retarding Valve Timing and Super Charging)

  • 이광주;허상훈;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.464-470
    • /
    • 2009
  • In order to analysis the possibility of high expansion and performance without backfire in a hydrogenfueled engine using external mixture injection, combustion characteristics and performance enhancement were analyzed in terms of retarding valve timing and increasing the boosting pressure. As the results, it was found that thermal efficiency increased by retarding intake valve timing with the same level of supplied energy is over 6.6% by the effect of high expansion including effect of combustion enhancement due to supercharging. It was also shown that the achievement of high power (equal to that of a gasoline engine), low brake specific fuel consumption and low emission (NOx of less than 16 ppm) without backfire in a hydrogen-fueled engine is possible around a boosting pressure of 1.5 bar, intake valve opening time of TDC and $\Phi$=0.35 in fuel-air equivalence ratio.

JPEG 인코더를 위한 고성능 병렬 프로세서 하드웨어 설계 및 검증 (Design and Verification of High-Performance Parallel Processor Hardware for JPEG Encoder)

  • 김용민;김종면
    • 대한임베디드공학회논문지
    • /
    • 제6권2호
    • /
    • pp.100-107
    • /
    • 2011
  • As the use of mobile multimedia devices is increasing in the recent year, the needs for high-performance multimedia processors are increasing. In this regard, we propose a SIMD (Single Instruction Multiple Data) based parallel processor that supports high-performance multimedia applications with low energy consumption. The proposed parallel processor consists of 16 processing elements(PEs) and operates on a 3-stage pipelining. Experimental results for the JPEG encoding algorithm indicate that the proposed parallel processor outperforms conventional parallel processors in terms of performance and energy efficiency. In addition, the proposed parallel processor architecture was developed and verified with verilog HDL and a FPGA prototype system.

Energy Modeling of a Supertall Building Using Simulated 600 m Weather File Data

  • Irani, Ali;Leung, Luke;Sedino, Marzia
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.101-106
    • /
    • 2019
  • Assessing the energy performance of supertall buildings often does not consider variations in energy consumption due to the change of environmental conditions such as temperature, pressure, and wind speed associated with differing elevations. Some modelers account for these changing conditions by using a conventional temperature lapse rate, but not many studies confirm to the appropriateness of applying it to tall buildings. This paper presents and discusses simulated annual energy consumption results from a 600 m tall skyscraper floor plate located in Dubai, UAE, assessed using ground level weather data, a conventional temperature lapse rate of $6.5^{\circ}C/km$, and more accurate simulated 600 m weather data. A typical office floorplate, with ASHRAE 90.1-2010 standards and systems applied, was evaluated using the EnergyPlus engine through the OpenStudio graphical user interface. The results presented in this paper indicate that by using ground level weather data, energy consumption at the top of the building can be overestimated by upwards of 4%. Furthermore, by only using a lapse rate, heating energy is overestimated by up to 96% due to local weather phenomenon such as temperature inversion, which can only be conveyed using simulated weather data. In addition, sizing and energy consumption of fans, which are dependent both on wind and atmospheric pressure, are not accurately captured using a temperature lapse rate. These results show that that it is important, with the ever increasing construction of supertall buildings, to be able to account for variations in climatic conditions along the height of the building. Adequately modeling these conditions using simulated weather data will help designers and engineers correctly size mechanical systems, potentially decreasing overall building energy consumption, and ensuring that these systems are able to provide the necessary indoor conditions to maintain occupant comfort levels.

고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구 (Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

DRAM&PCM 하이브리드 메모리 시스템을 위한 능동적 페이지 교체 정책 (Active Page Replacement Policy for DRAM & PCM Hybrid Memory System)

  • 정보성;이정훈
    • 대한임베디드공학회논문지
    • /
    • 제13권5호
    • /
    • pp.261-268
    • /
    • 2018
  • Phase Change Memory(PCM) with low power consumption and high integration attracts attention as a next generation nonvolatile memory replacing DRAM. However, there is a problem that PCM has long latency and high energy consumption due to the writing operation. The PCM & DRAM hybrid memory structure is a fruitful structure that can overcome the disadvantages of such PCM. However, the page replacement algorithm is important, because these structures use two memory of different characteristics. The purpose of this document is to effectively manage pages that can be referenced in memory, taking into account the characteristics of DRAM and PCM. In order to manage these pages, this paper proposes an page replacement algorithm based on frequently accessed and recently paged. According to our simulation, the proposed algorithm for the DRAM&PCM hybrid can reduce the energy-delay product by around 10%, compared with Clock-DWF and CLOCK-HM.

isMAC: An Adaptive and Energy-Efficient MAC Protocol Based on Multi-Channel Communication for Wireless Body Area Networks

  • Kirbas, Ismail;Karahan, Alper;Sevin, Abdullah;Bayilmis, Cuneyt
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권8호
    • /
    • pp.1805-1824
    • /
    • 2013
  • Recently, the use of wireless body area networks (WBAN) has been increasing rapidly in medical healthcare applications. WBANs consist of smart nodes that can be used to sense and transmit vital data such as heart rate, temperature and ECG from a human body to a medical centre. WBANs depend on limited resources such as energy and bandwidth. In order to utilise these resources efficiently, a very well organized medium access control (MAC) protocol must be considered. In this paper, a new, adaptive and energy-efficient MAC protocol, entitled isMAC, is proposed for WBANs. The proposed MAC is based on multi-channel communication and aims to prolong the network lifetime by effectively employing (i) a collision prevention mechanism, (ii) a coordinator node (WCN) selection algorithm and (iii) a transmission power adjustment approach. The isMAC protocol has been developed and modelled, by using OPNET Modeler simulation software. It is based on a networking scenario that requires especially high data rates such as ECG, for performance evaluation purposes. Packet delay, network throughput and energy consumption have been chosen as performance metrics. The comparison between the simulation results of isMAC and classical IEEE 802.15.4 (ZigBee) protocol shows that isMAC significantly outperforms IEEE 802.15.4 in terms of packet delay, throughput and energy consumption.