• 제목/요약/키워드: High efficiency operation

검색결과 1,907건 처리시간 0.029초

레이디얼 피스톤 펌프의 효율 특성 연구 (A Characteristic Study of Efficiency in Radial Piston Pump)

  • 장윤석;천세민;임윤철
    • Tribology and Lubricants
    • /
    • 제16권4호
    • /
    • pp.259-265
    • /
    • 2000
  • Pump which is the fundamental device in the hydraulic system affects on overall system performance to a great deal. Such problems as leakage and solid friction loss become important in field applications, especially for the case of operation under high pressure and at high speed. So the research on this kind of subjects is necessary to improve the performance of hydraulic devices. A high pressure radial piston pump is analyzed here, which has a stationary cylinder block. It pumps hydraulic fluid by letting camring push a piston in a cylinder. Fluid leaks between the piston and cylinder so that it deteriorates the pump efficiency. Furthermore, the piston happens to touch the cylinder wall to increase the friction loss and wear. In this research, by means of FDA, volumetric, mechanical and overall efficiencies are observed by varying several design parameters and operation conditions. Design values or their trends are presented to improve these effciencies.

부분공진기법에 의한 고효율 인버터 시스템 (High Efficiency Inverter System by Partial Resonant Method)

  • 김영철;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.39-43
    • /
    • 1998
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The switching devices in a proposed circuits are operated with soft switching by the partial resonant method, that is, PRS2MPC (Partial Resonant Soft Switching Mode Power Converter). The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

A High Efficiency and High Power Chopper Circuit QRAS using Soft Switching under Test Evaluation at 8kW

  • Tsuruta Yukinori;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This paper is a record of the study on a high efficiency and high power chopper based on the new soft switching method QRAS (Quasi~resonant Regenerating Active Snubber) designed for a Fuel Cell Electric Vehicle (FCEV). This power chopper is basically proposed for 25kHz soft switching. To confirm the practicality and effectiveness of the converter, the fabrication of a prototype-model using IGBTs was completed. Additionally, a 8kW rating test, a light load test, a current discontinuous mode test and a stable operation resonance test was completed. The circuit geometry, the basic operation, and the 8kW one-tenth-prototype test results are reported with a $97.5\%$ efficiency measurement.

고열을 이용한 잔류 오존($O_3$) 처리에 관한 연구 (The study on the treatment of the remaining Ozone($O_3$) by the high heater)

  • 김재우
    • 환경위생공학
    • /
    • 제16권2호
    • /
    • pp.9-16
    • /
    • 2001
  • If a pollutant invade at liguid and gas, it will be use ozone in order to remove or sterilize. Ozone excessively supply in order to receive satisfactory efficiency. If excessive ozone leave like that, second-problem will be occur. This study used high heater in order to treat occurred ozone. ; the results were as follow : 1. As initial ozone os supplied with $1.789{\;}g/m^3$ : For the 40, 50, 60, 70(V) of electric potential $O_3$ removal efficiency was treated 34.41, 73.78, 98.60, 98.97%(time of operation ; after 5min.). 2. As initial ozone is supplied with $3.645{\;}g/m^3$ : For the 40, 50, 60, 70(V) of electric potential, $O_3$ removal efficiency was treated 1.78, 69.27, 99.18, 98.68%(time of operation ; after 5min.). 3. As initial ozone is supplied with $4.759{\;}g/m^3$ : For the 50, 60, 70(V) of electric potential, $O_3$ removal efficiency was treated 61.29, 99.29, 99.18%(Time of operation ; after 5min.). 4. Used electric power is 15.38, 24.00, 35.29, 46.15(w/hr) at the 40, 50, 60, 70(V) of the electric potential. 5. Regarding electric power and $O_3$ removal efficiency, Used electric pote-ntial economized at 60(V).

  • PDF

Design of Parasitic Inductance Reduction in GaN Cascode FET for High-Efficiency Operation

  • Chang, Woojin;Park, Young-Rak;Mun, Jae Kyoung;Ko, Sang Choon
    • ETRI Journal
    • /
    • 제38권1호
    • /
    • pp.133-140
    • /
    • 2016
  • This paper presents a method of parasitic inductance reduction for high-speed switching and high-efficiency operation of a cascode structure with a low-voltage enhancement-mode silicon (Si) metal-oxide-semiconductor field-effect transistor (MOSFET) and a high-voltage depletion-mode gallium nitride (GaN) fielde-ffect transistor (FET). The method is proposed to add a bonding wire interconnected between the source electrode of the Si MOSFET and the gate electrode of the GaN FET in a conventional cascode structure package to reduce the most critical inductance, which provides the major switching loss for a high switching speed and high efficiency. From the measured results of the proposed and conventional GaN cascode FETs, the rising and falling times of the proposed GaN cascode FET were up to 3.4% and 8.0% faster than those of the conventional GaN cascode FET, respectively, under measurement conditions of 30 V and 5 A. During the rising and falling times, the energy losses of the proposed GaN cascode FET were up to 0.3% and 6.7% lower than those of the conventional GaN cascode FET, respectively.

A SiC MOSFET Based High Efficiency Interleaved Boost Converter for More Electric Aircraft

  • Zaman, Haider;Zheng, Xiancheng;Yang, Mengxin;Ali, Husan;Wu, Xiaohua
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.23-33
    • /
    • 2018
  • Silicon Carbide (SiC) MOSFET belongs to the family of wide-band gap devices with inherit property of low switching and conduction losses. The stable operation of SiC MOSFET at higher operating temperatures has invoked the interest of researchers in terms of its application to high power density (HPD) power converters. This paper presents a performance study of SiC MOSFET based two-phase interleaved boost converter (IBC) for regulation of avionics bus voltage in more electric aircraft (MEA). A 450W HPD, IBC has been developed for study, which delivers 28V output voltage when supplied by 24V battery. A gate driver design for SiC MOSFET is presented which ensures the operation of converter at 250kHz switching frequency, reduces the miller current and gate signal ringing. The peak current mode control (PCMC) has been employed for load voltage regulation. The efficiency of SiC MOSFET based IBC converter is compared against Si counterpart. Experimentally obtained efficiency results are presented to show that SiC MOSFET is the device of choice under a heavy load and high switching frequency operation.

Design of 32 bit Parallel Processor Core for High Energy Efficiency using Instruction-Levels Dynamic Voltage Scaling Technique

  • Yang, Yil-Suk;Roh, Tae-Moon;Yeo, Soon-Il;Kwon, Woo-H.;Kim, Jong-Dae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2009
  • This paper describes design of high energy efficiency 32 bit parallel processor core using instruction-levels data gating and dynamic voltage scaling (DVS) techniques. We present instruction-levels data gating technique. We can control activation and switching activity of the function units in the proposed data technique. We present instruction-levels DVS technique without using DC-DC converter and voltage scheduler controlled by the operation system. We can control powers of the function units in the proposed DVS technique. The proposed instruction-levels DVS technique has the simple architecture than complicated DVS which is DC-DC converter and voltage scheduler controlled by the operation system and a hardware implementation is very easy. But, the energy efficiency of the proposed instruction-levels DVS technique having dual-power supply is similar to the complicated DVS which is DC-DC converter and voltage scheduler controlled by the operation system. We simulate the circuit simulation for running test program using Spectra. We selected reduced power supply to 0.667 times of the supplied power supply. The energy efficiency of the proposed 32 bit parallel processor core using instruction-levels data gating and DVS techniques can improve about 88.4% than that of the 32 bit parallel processor core without using those. The designed high energy efficiency 32 bit parallel processor core can utilize as the coprocessor processing massive data at high speed.

파이프형 원심펌프의 성능특성에 관한 실험적 연구 (Performance Characteristic of a Pipe Type Centrifugal Pump)

  • 유현주;강신형
    • 한국유체기계학회 논문집
    • /
    • 제15권5호
    • /
    • pp.32-36
    • /
    • 2012
  • The positive displacement pump and the regenerative pump are widely used in the range of low specific speed, $n_s{\leq}100$[rpm, m3/min, m]. The positive displacement pump is not suitable for miniaturization and operation in high rotational speed. The regenerative pump has a problem with large leakage flow and low efficiency. While the centrifugal pump has advantages of high efficiency, miniaturization and high rotational speed, efficiency drops sharply with decrease in specific speed. Therefore the purpose of this study is to design a new type of centrifugal pump that has advantages of centrifugal pumps in operation in low specific speed. The name of this new type of pump was called 'Pipe type centrifugal pump', since the flow path through the impeller is simple circular pipe. Due to the simple shape of impeller, the manufacturing process is simple and cost is low. There is strong jet flow at the outlet of the impeller. This jet induces flow path loss, meridional dynamic pressure loss and mixing loss. Large disk friction makes the efficiency be limitted in the range of low specific speed. Even though the loss and the low efficiency, 'Pipe type centrifugal pump' represents stable performance, affordable pressure ratio and efficiency better than that of other low specific speed pumps.

철도전철화 효과 계량지표 개발에 관한 연구 (A study on development of measuring index about railway electrification effectiveness)

  • 김재희;박용걸;양근율;정호성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1575-1580
    • /
    • 2006
  • High speed and large transfer capability of railroad has been an important issue in Korean since KTX opening at 2004. Improvement projects for railway electrification are progressed in the conventional line as well as high speed line because various operation plan is performed such as interaction between high speed line and conventional line and operation of tilting train etc. Especially, railway electrification has many advantages which are cost effective and eco-friendly. But it also has some problems such as construction costs and accidents due to electrification. Therefore this paper developed measuring index of electrification railway benefit. By comparing between diesel and electrical locomotive, the operations of before and after the electrification and measurements quantitative index such as energy efficiency, enlargement of transfer capability, environmental pollution and maintenance and efficiency of operation is presented. In the future, Overall benefit and cost of railway electrification will be analyzed.

  • PDF

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.