• 제목/요약/키워드: High efficiency operation

검색결과 1,911건 처리시간 0.033초

고성능 절연형 벅-부스트 컨버터의 특성 해석에 관한 연구 (A Study on the Characteristic analyses of High Performance Buck-Boost Converter added Electric Isolation)

  • 곽동걸;정도영;이봉섭;김춘삼;심재선;양기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.142-144
    • /
    • 2008
  • This paper is studied on the characteristic analyses of a high performance buck-boost converter added electric isolation by using a soft switching method. To be achieved of a high performance system, the proposed buck-boost converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a Partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with the system development of high efficiency. The soft switching operation and system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

Corrosion behavior of refractory metals in liquid lead at 1000 ℃ for 1000 h

  • Xiao, Zunqi;Liu, Jing;Jiang, Zhizhong;Luo, Lin
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.1954-1961
    • /
    • 2022
  • Lead-based fast reactor (LFR) has become one of the most promising reactors for Generation IV nuclear systems. A developing trend of LFR is high efficiency, along with operation temperatures up to 800 ℃ or even higher. One of key issues in the high-efficiency LFR is corrosion of cladding materials with lead at high temperatures. In this study, corrosion behavior of some refractory metals (Nb, Nb521, and Mo-0.5La) was investigated in static lead at 1000 ℃ for 1000 h. The results showed that Nb and Nb521 exhibited an intense dissolution corrosion with obvious lead penetration after corrosion, and lead penetration extended along the grain boundaries of the specimens. Furthermore, Nb521 showed a better corrosion resistance than that of Nb as a result of the elements of W and Mo included in Nb521. Mo-0.5La showed much better corrosion resistance than that of Nb and Nb521, and no lead penetration could be observed. However, an etched morphology appeared on the surface of Mo-0.5La, indicating the occurrence of corrosion to a certain degree. The results indicate that Mo-0.5La is compatible with lead up to 1000 ℃. While Nb and Nb alloys might be not compatible with lead for high-efficiency LFR at such high temperatures.

가변 주파수 Sono-Fenton 산화를 이용한 Spent-GAC 재생기술 (Spent-GAC Regeneration Using Variable Frequency Sono-Fenton Oxidation)

  • 주수빈;이상민;김형준;심인태;김희진
    • 대한토목학회논문집
    • /
    • 제43권4호
    • /
    • pp.449-458
    • /
    • 2023
  • 용존 유기물을 흡착 제거하는 기술로서, 흡착능이 우수한 입상활성탄을 우선적으로 적용할 수 있지만, 흡착탑의 운전기간에 따라 GAC의 흡착능이 현저히 저하되어 파과되는 한계가 있으며 파과된 활성탄인 spent-GAC는 교체나 재생이 불가피하다. 활성탄 교체는 비용의 경제성 때문에 기피되며 상업적으로 열재생법을 사용하고 있으나, 800℃ 이상의 고온 조건으로 인한 높은 에너지 비용과 활성탄의 질량 손실이 발생하는 단점이 있다. 본 연구에서는 CSOs내의 용존 유기물 처리에 사용된 spent-GAC의 재생효율을 제고하기 위해, Fenton 산화법과 초음파 산화를 융합한 다중산화기술인 Sono-Fenton 방법을 적용하였고, 산화제 주입농도와 초음파 주파수별 spent-GAC의 재생효율을 조사하였다. 적용된 Sono-Fenton 처리에서 Fe2+ 10 mmol/L, H2O2 농도 1,000 mmol/L, 120분 초음파 주사시간, 초음파 주파수 40 kHz 재생처리 조건에서 68.5%의 가장 높은 재생효율을 얻을 수 있었고, 750 kHz에서도 유사한 효율을 얻을 수 있었으며, 다른 주파수의 초음파는 재생효율이 불량했고 주파수의 크기와 GAC 재생효율은 선형 관계를 나타내지 않았다. 실 하수를 희석하여 제조한 CSOs로 GAC 흡착탑을 연속운전 한 경우, 재생없이 700시간 내외의 운전이 가능했고 1회의 Sono-Fenton 처리를 적용한 결과, 총 1,000시간의 GAC 흡착 운전 기간 동안 40~70%의 CODcr 제거 효율이 확보하였다.

점성이 높은 유체를 사용하는 펌프의 성능해석 (Pump Performance Analyses with High Viscous Fluids)

  • 김동주;노형운;서상호
    • 한국유체기계학회 논문집
    • /
    • 제7권2호
    • /
    • pp.21-26
    • /
    • 2004
  • In this study the effects of fluid viscosity on the pump performances for a conventional centrifugal pump were experimentally investigated. The study aimed to compare the pump characteristics between water and viscosity fluids. In order to measure the flow rate and pressure, v-notch welt and bourdon pressure gauges were used for the codes of KS B6301 and KS B6302. The working fluids were water, aqueous sugar and glycerin solutions. The results were summarized as follows : The experimental results were summarized as follows : the pump characteristics of the total head, shaft power, and efficiency with high viscosity fluids were different from those of water. When the viscosity of the applied fluid was increased, the total head and efficiency were more decreased than those of water. The decreasing gradients of the total head and the efficiency were larger than water due to the increased disk friction losses at the duty operation point. However, the shut-off head was almost constant regardless the viscosity of applied fluids. Each efficiency curves for the sugar $20w\%$ and glycerin $20w\%$ solutions was decreased up to $15.1\%$ and $34.4\%$ than that of water, respectively.

소프트 스위칭에 의한 절연형 벅-부스트 컨버터에 관한 연구 (A Study on Soft Switching Buck-Boost Converter added Electric Isolation)

  • 곽동걸;정도영;이봉섭;최신형;김상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.922-923
    • /
    • 2008
  • This paper is proposed to a novel DC-DC buck-boost converter added electric isolation by using a soft switching method. To be achieved of high efficiency system, the proposed converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

GaN MOSFET을 이용한 고밀도, 고효율 48V 버스용 3-출력 Buck Converter 설계 (A High Efficiency, High Power-Density GaN-based Triple-Output 48V Buck Converter Design)

  • 이상민;이승환
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a 70 W buck converter using GaN metal-oxide-semiconductor field-effect transistor (MOSFET) is developed. This converter exhibits over 97 % efficiency, high power density, and 48 V-to-12 V/1.2 V/1 V (triple output). Three gate drivers and six GaN MOSFETs are placed in a 1 ㎠ area to enhance power density and heat dissipation capacity. The theoretical switching and conduction losses of the GaN MOSFETs are calculated. Inductances, capacitances, and resistances for the output filters of the three buck converters are determined to achieve the desired current, voltage ripples, and efficiency. An equivalent circuit model for the thermal analysis of the proposed triple-output buck converter is presented. The junction temperatures of the GaN MOSFETs are estimated using the thermal model. Circuit operation and temperature analysis are evaluated using a circuit simulation tool and the finite element analysis results. An experimental test bed is built to evaluate the proposed design. The estimated switch and heat sink temperatures coincide well with the measured results. The designed buck converter has 130 W/in3 power density and 97.6 % efficiency.

우수한 공통 모드 노이즈 특성을 가진 브릿지 다이오드가 없는 고효율 PFC 컨버터 (High Efficiency Bridgeless Power Factor Correction Converter With Improved Common Mode Noise Characteristics)

  • 장효서;이주영;김문영;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.85-91
    • /
    • 2022
  • This study proposes a high efficiency bridgeless Power Factor Correction (PFC) converter with improved common mode noise characteristics. Conventional PFC has limitations due to low efficiency and enlarged heat sink from considerable conduction loss of bridge diode. By applying a Common Mode (CM) coupled inductor, the proposed bridgeless PFC converter generates less conduction loss as only a small magnetizing current of the CM coupled inductor flows through the input diode, thereby reducing or removing heat sink. The input diode is alternately conducted every half cycle of 60 Hz AC input voltage while a negative node of AC input voltage is always connected to the ground, thus improving common mode noise characteristics. With the aim to improve switching loss and reverse recovery of output diode, the proposed circuit employs Critical Conduction Mode (CrM) operation and it features a simple Zero Current Detection (ZCD) circuit for the CrM. In addition, the input current sensing is possible with the shunt resistor instead of the expensive current sensor. Experimental results through 480 W prototype are presented to verify the validity of the proposed circuit.

부지연 회로를 내장한 200MHz 고속 16M SDRAM (A 200MHz high speed 16M SDRAM with negative delay circuit)

  • 김창선;장성진;김태훈;이재구;박진석;정웅식;전영현
    • 전자공학회논문지C
    • /
    • 제34C권4호
    • /
    • pp.16-25
    • /
    • 1997
  • This paper shows a SDRAM opeating in 200MHz clock cycle which it use data interleave and pipelining for high speed operation. We proposed NdC (Negative DEaly circuit) to improve clock to access time(tAC) characteristics, also we proposed low power WL(wordline)driver circit and high efficiency VPP charge-pump circit. Our all circuits has been fabricated using 0.4um CMOS process, and the measured maximum speed is 200Mbytes/s in LvTTL interface.

  • PDF

스프트 스위칭 보조 스위치를 가지는 ZVT-PWM 부스트 컨버터 (A High Performance ZVT-PWM Boost Rectifier with Soft Switched Auxiliary Switch)

  • 김윤호;김윤복;정재웅
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.265-268
    • /
    • 1998
  • This paper presents a soft-switching average current control PWM high power factor boost converter. Conventional boost ZVT-PWM converter has a disadvantage of hard-switching for auxiliary switch at turn-off. A soft switched auxiliary switch is proposed to achieve a high performance ZVT-PWM boost rectifier. The simulation and experimental results show that soft switching operation can be maintained for wide line and load range, which in turn improves the converter performance in terms of efficiency, switching noise and circuit reliability.

  • PDF

시뮬레이터를 이용한 정지형 개폐기 여자돌입전류 분석 (The Analysis of the Inrush Current of Main Transformer Using the Simulator)

  • 신효범;한문섭;장동욱;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2005-2010
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper analyzed inrush current of main transformer that installed on the train while passing through the neutral section using the simulator.

  • PDF