• Title/Summary/Keyword: High current measuring

Search Result 479, Processing Time 0.023 seconds

Development of Wireless Smart Sensing Framework for Structural Health Monitoring of High-speed Railway Bridges (고속 철도 교량의 구조 건전성 모니터링을 위한 스마트 무선 센서 프레임워크 개발)

  • Kim, Eunju;Park, Jong-Woong;Sim, Sung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.1-9
    • /
    • 2016
  • Railroad bridges account for 25% of the entire high-speed rail network. Railway bridges are subject to gradual structural degradation or fatigue accumulation due to consistent and repeating excitation by fast moving trains. Wireless sensing technology has opened up a new avenue for bridge health monitoring owing to its low-cost, high fidelity, and multiple sensing capability. On the other hand, measuring the transient response during train passage is quite challenging that the current wireless sensor system cannot be applied due to the intrinsic time delay of the sensor network. Therefore, this paper presents a framework for monitoring such transient responses with wireless sensing systems using 1) real-time excessive vibration monitoring through ultra-low-power MEMS accelerometers, and 2) post-event time synchronization scheme. The ultra-low power accelerometer continuously monitors the vibration and trigger network when excessive vibrations are detected. The entire network of wireless smart sensors starts sensing through triggering and the post-event time synchronization is conducted to compensate for the time error on the measured responses. The results of this study highlight the potential of detecting the impact load and triggering the entire network, as well as the effectiveness of the post-event time synchronized scheme for compensating for the time error. A numerical and experimental study was carried out to validate the proposed sensing hardware and time synchronization method.

A Study on the RDF Manufacturing of Coffee grounds by using Pilot scale Oil-drying Equipment (Pilot scale 유중건조 장비를 이용한 커피찌꺼기의 고형연료화 연구)

  • Kwon, Ik-Beom;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.443-450
    • /
    • 2019
  • We studied to find the optimal manufacturing conditions of coffee grounds sludge RDF with oil drying method. We expanded the lab scale to pilot scale to compare the efficiency of the oil-drying equipment and The selection of the ratio of coffee grounds and oil, the setting temperature, and the temperature change and water content with time were measured. In order to analyze the characteristics of the research results, characteristics of solid fuels produced(Coffee grounds of oil-dried) by calorimeter, TGA, combustion equipment, and combustion gas measuring instrument were analyzed. As a result, the ratio of oil to coffee grounds was 4: 1, and when the setting temperature was set to $300^{\circ}C$, the water content reached 10wt.% or less within 20 minutes. ln addition, it showed high calorific value of 6,273kcal/kg. However, coffee grounds had a similar composition to wood and showed high luminance and produced a lot of CO in combustion gas. As a result, it is considered to be unsuitable for thermoelectric power plant and camping fuel, but the initial ignition speed is high and the heat generation is high, so it is considered that it can replace the fuels for current use.

Evaluation of Antenna Pattern Measurement of HF Radar using Drone (드론을 활용한 고주파 레이다의 안테나 패턴 측정(APM) 가능성 검토)

  • Dawoon Jung;Jae Yeob Kim;Kyu-Min Song
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.109-120
    • /
    • 2023
  • The High-Frequency Radar (HFR) is an equipment designed to measure real-time surface ocean currents in broad maritime areas.It emits radio waves at a specific frequency (HF) towards the sea surface and analyzes the backscattered waves to measure surface current vectors (Crombie, 1955; Barrick, 1972).The Seasonde HF Radar from Codar, utilized in this study, determines the speed and location of radial currents by analyzing the Bragg peak intensity of transmitted and received waves from an omnidirectional antenna and employing the Multiple Signal Classification (MUSIC) algorithm. The generated currents are initially considered ideal patterns without taking into account the characteristics of the observed electromagnetic wave propagation environment. To correct this, Antenna Pattern Measurement (APM) is performed, measuring the strength of signals at various positions received by the antenna and calculating the corrected measured vector to radial currents.The APM principle involves modifying the position and phase information of the currents based on the measured signal strength at each location. Typically, experiments are conducted by installing an antenna on a ship (Kim et al., 2022). However, using a ship introduces various environmental constraints, such as weather conditions and maritime situations. To reduce dependence on maritime conditions and enhance economic efficiency, this study explores the possibility of using unmanned aerial vehicles (drones) for APM. The research conducted APM experiments using a high-frequency radar installed at Dangsa Lighthouse in Dangsa-ri, Wando County, Jeollanam-do. The study compared and analyzed the results of APM experiments using ships and drones, utilizing the calculated radial currents and surface current fields obtained from each experiment.

University Enrollment Policy in the Capital Region and Its Impact on Population Dispersal (수도권 대학정원정책의 수동권 인구분산교과에 관한 연구)

  • 임창호;구자훈;안근원
    • Journal of the Korean Regional Science Association
    • /
    • v.9 no.1
    • /
    • pp.45-63
    • /
    • 1993
  • University enrollment has long been regarded as one of the major factors inducing population concentration in Seoul and the Capital Region of Korea. Consequently, since early 1980's increases in enrollment and new establishments of extention universities beyond the boundary of Seoul, has been promoted, while university enrollment quota in Seoul has been strictly controlled. The degree of actual population dispersal, however, resulting from such a university enrollment policy has not been empirically tested. This paper aims at: First, identifying the trend of population growth and evolution process of the university enrollment policy in the Capital Region; Second, comparing the degree of influence of university enrollment on population concetration factors; Third, measuring actual effect of the enrollment control on population dispersal out of Seoul and the Capital Region. Major findings are as follows: First, only a week correlation between population and university enrollment growth trends was found; Second, the relative degree of influence on population concentration in the Capital Region, were order, in the order of magnitude, the physical amenity factor, the socio-cultural amenity factor, the employment climate factor and the educational factor. Third, and most improtant, based on the comparison of spatial distribution of graduated high schools and current residence of the selected university students, the gap between the two distributions was revealed and the inter-regional student population movement was estimated. The result shows that in Seoul's case about one-half of and in Kyunggi Province's case about one-fifth of university enrollment size, contributes to population concentration into Seoul. Fourth, as to the universities outside of the Capital Region, little effect in the case of universities located within the commuting distance, and a little effect on population dispersal in the case of universities located beyond commuting distance, were found. In sum, it seems clear that university enrollment policy in the Capital Region, especially in Inchon/Kyunggi Province has not been effective on student population dispersal out of Seoul and the Capital Region. Therefore, it is strongly recommended that university enrollment policy be throughly re-examined from its goal to the implementation means.

  • PDF

Design of a Low-Power LDPC Decoder by Reducing Decoding Iterations (반복 복호 횟수 감소를 통한 저전력 LDPC 복호기 설계)

  • Lee, Jun-Ho;Park, Chang-Soo;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.9C
    • /
    • pp.801-809
    • /
    • 2007
  • LDPC Low Density Parity Check) code, which is an error correcting code determined to be applied to the 4th generation mobile communication systems, requires a heavy computational complexity due to iterative decodings to achieve a high BER performance. This paper proposes an algorithm to reduce the number of decoding iterations to increase performance of the decoder in decoding latency and power consumption. Measuring changes between the current decoded LLR values and previous ones, the proposed algorithm predicts directions of the value changes. Based on the prediction, the algorithm inverts the sign bits of the LLR values to speed up convergence, which means parity check equation is satisfied. Simulation results show that the number of iterations has been reduced by about 33% without BER performance degradation in the proposed decoder, and the power consumption has also been decreased in proportional to the amount of the reduced decoding iterations.

Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP (다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석)

  • Ji, Ju-Yeon;Park, Seung-Yong;Lee, Gwang-Woo;Park, Gyeong-Min;Hwang, Soon-Hong;Kim, Dong-Ho;Lee, Young-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

A Unit Touch Gesture Model of Performance Time Prediction for Mobile Devices

  • Kim, Damee;Myung, Rohae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.277-291
    • /
    • 2016
  • Objective: The aim of this study is to propose a unit touch gesture model, which would be useful to predict the performance time on mobile devices. Background: When estimating usability based on Model-based Evaluation (MBE) in interfaces, the GOMS model measured 'operators' to predict the execution time in the desktop environment. Therefore, this study used the concept of operator in GOMS for touch gestures. Since the touch gestures are comprised of possible unit touch gestures, these unit touch gestures can predict to performance time with unit touch gestures on mobile devices. Method: In order to extract unit touch gestures, manual movements of subjects were recorded in the 120 fps with pixel coordinates. Touch gestures are classified with 'out of range', 'registration', 'continuation' and 'termination' of gesture. Results: As a results, six unit touch gestures were extracted, which are hold down (H), Release (R), Slip (S), Curved-stroke (Cs), Path-stroke (Ps) and Out of range (Or). The movement time predicted by the unit touch gesture model is not significantly different from the participants' execution time. The measured six unit touch gestures can predict movement time of undefined touch gestures like user-defined gestures. Conclusion: In conclusion, touch gestures could be subdivided into six unit touch gestures. Six unit touch gestures can explain almost all the current touch gestures including user-defined gestures. So, this model provided in this study has a high predictive power. The model presented in the study could be utilized to predict the performance time of touch gestures. Application: The unit touch gestures could be simply added up to predict the performance time without measuring the performance time of a new gesture.

A Study on the Damage by Burning Characteristics of Insulating Materials of RCD (누전차단기 절연재료의 소손 특성에 관한 연구)

  • Lee, Chun-Ha;Kim, Shi-Kuk;Ok, Kyung-Jae;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • In this study, we study the damage by burning characteristics of insulating material of RCD (Residual Current Device) used in Korea. The insulating materials of RCD manufactured by three manufacturers are used as the sample. We compare and analyze the thermal decomposition characteristics, combustion characteristics and tracking characteristics of samples. The TGA and Mass Loss Calorimeter meeting the requirements for the ISO5660 (Fire tests-Reaction to Fire, part 1) are used for analyzing the thermal decomposition characteristics and combustion characteristics respectively. In addition, the tracking characteristics are analyzed according to standard of KSC IEC 60112 known as the test used for measuring the resistance tracking and comparison tracking indexes. The study results show that the resistance tracking property of insulating material provided by A Company is highest. Also, the test results show that the resistance tracking property of insulating material provided by B Company is lowest. However, the thermal stability of insulating material provided by this company is excellent at high temperature of above $350^{\circ}C$. In addition, the test results show that the thermal stability of insulating material provided by C Company is highest at temperature of below $400^{\circ}C$.

Development and Validation of the Ego Strength Scale for Children (아동 자아강도 척도의 개발 및 타당화)

  • Kim, Se Young;Park, Boo Jin
    • Human Ecology Research
    • /
    • v.51 no.5
    • /
    • pp.537-549
    • /
    • 2013
  • The purpose of this study was to develop an objective Ego Strength Scale for Children useful in research and clinical fields for measuring the ego strength of 3rd-6th grade children and to test its validity and reliability. For these purposes, we conducted a two-stage study. First, the scale was developed through data collection, composition of components and questions, a preliminary survey, and a main survey. The main survey was conducted with 1,185 3rd-6th grade children in Seoul and Gyeonggi province, and analyzed through exploratory factor analysis and reliability analysis. Second, the scale we developed was validated through confirmatory factor analysis and convergent-discriminant validity analysis for testing validity related to internal structure. The secondary survey was conducted with 5,494 3rd-6th grade children in Seoul and the province of Gyeonggi, Chungcheong, Gangwon, Jeolla, Gyeongsang, and Jeju. The study concluded the following: First, the scale was designed to measure 4 factors: competence, initiative, elasticity, and sociability using 26 questions. Second, the Ego Strength Scale for Children was found to be highly valid through validity tests. In addition, it showed high reliability in an internal consistency test and split-half reliability test. As this study developed and validated the Ego Strength Scale for Children in the current situation in which there are few objective instruments to measure children's ego strength, it is meaningful in that it laid the basis for broader future research on ego strength.

Mapping the Polarization of the Radio-Loud Lyman Alpha Nebula B3 J2330+3927

  • Yang, Yujin;You, Chang;Zabludoff, Ann;Smith, Paul;Jannuzi, Buell;Prescott, Moire
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.28.3-29
    • /
    • 2015
  • $Ly{\alpha}$ nebulae, or "$Ly{\alpha}$ blobs", are extended (~100 kpc), bright (L[$Ly{\alpha}$] ~ 1044 erg/s) clouds of $Ly{\alpha}$-emitting gas. The origin of the $Ly{\alpha}$ emission remains unknown, but recent theoretical work suggests that measuring the polarization could discriminate among powering mechanisms. we will discuss current status of $Ly{\alpha}$ polarization observations at high-redshift and our on-going survey program. We will present the first narrow-band, imaging polarimetry of a $Ly{\alpha}$ blob, B3 J2330+3927 at z=3.09, with an embedded, radio-loud AGN (C. You et al. in prep.). The AGN lies near the blob's $Ly{\alpha}$ emission peak and its radio lobes align roughly with the blob's semi-major axis. With the SPOL polarimeter on the MMT telescope, we map the polarization in a grid of circular apertures of radius 0.6" (4.4 kpc), detecting a significant (>$2{\sigma}$) polarization fraction P% in 10 apertures and achieving strong upper-limits (as low as 2%) elsewhere. The degree of the polarization map increases from P% ~ 5% at ~5 kpc from the blob center to ~20% at the outer part (~30 kpc). The detections are distributed asymmetrically, roughly along the blob's major axis. The polarization angles (${\Theta}$) are mostly perpendicular to this axis. These results are consistent with the picture that $Ly{\alpha}$ photons produced at the AGN (or the host galaxy) are resonantly scattered away from the center. Higher polarization fraction on the radio jet suggests that the gas is more optically thin along the jet than the off-axis region.

  • PDF