• 제목/요약/키워드: High Voltage Generator

검색결과 573건 처리시간 0.026초

고집적 메모리의 yield 개선을 위한 전기적 구제회로 (An Electrical Repair Circuit for Yield Increment of High Density Memory)

  • 김필중;김종빈
    • 한국전기전자재료학회논문지
    • /
    • 제13권4호
    • /
    • pp.273-279
    • /
    • 2000
  • Electrical repair method which has replaced laser repair method can replace defective cell by redundancy’s in the redundancy scheme of conventional high density memory. This electrical repair circuit consists of the antifuse program/read/latch circuits, a clock generator a negative voltage generator a power-up pulse circuit a special address mux and etc. The measured program voltage of made antifuses was 7.2~7.5V and the resistance of programmed antifuses was below 500 Ω. The period of clock generator was about 30 ns. The output voltage of a negative voltage generator was about 4.3 V and the current capacity was maximum 825 $mutextrm{A}$. An antifuse was programmed using by the electric potential difference between supply-voltage (3.3 V) and output voltage generator. The output pulse width of a power-up pulse circuit was 30 ns ~ 1$mutextrm{s}$ with the variation of power-up time. The programmed antifuse resistance required below 44 ㏀ from the simulation of antifuse program/read/latch circuit. Therefore the electrical repair circuit behaved safely and the yield of high densitymemory will be increased by using the circuit.

  • PDF

고전압 펄스 발생 장치의 회로에 관한 이론적 연구 (Theoretical Study of the Circuits for Device of the High Voltage Pulse Generator)

  • 김영주
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.99-108
    • /
    • 2013
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed using Miller's theorem and network theory(ABCD Matrix) and simulated in frequency and time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 1.8kV. Output pulse voltage increases as $L_m$ increases in low voltage circuit. In high voltage circuit, outer capacitors are related to frequency band pass characteristics.

트랜스포머를 이용한 고전압 펄스 발생 장치의 설계와 측정평가에 관한 연구 (Study for the Design and Measurement of the High Voltage Pulse Generator Using Transformers)

  • 김영주
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.82-86
    • /
    • 2012
  • High-capacity high-voltage pulse generator that can be used for environmental clean-up was developed using transformers. High-voltage pulse is consists of the primary wave and the harmonic wave which are increased as a series circuit using transformers to make pulses. Each transformer has a band-pass characteristics. The output voltage of the pulse width 50[%] was decided. The output voltage of high-voltage pulse generator device was measured as 1.4[kV] (Peak-to-Peak).

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

리액터 탭 설정값에 따른 유도발전기의 돌입전류와 전압강하 분석 (Analysis for the Inrush Current and Voltage Drop of Induction Generator by the Reactor Tap Change)

  • 김종겸
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1202-1206
    • /
    • 2015
  • The induction generator has many advantages compared to the synchronous generator in terms of cost and maintenance. So squirrel cage induction generator has been recently supplied in small hydroelectric power station. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the supply of the induction generator, it is very important to find the method of reducing inrush current and voltage drop.

고전압 펄스 발생 장치의 관한 부하의 변화를 고려한 펄스회로의 이론적 연구 (Theoretical Study of Pulse Circuits with the Load Variation for Device of the High Voltage Pulse Generator)

  • 김영주;방상석;이채한;김상현
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.106-112
    • /
    • 2016
  • The high-voltage pulse generator consists of transformers of fundamental wave and harmonic waves, and shunt capacitors. The pulse has the fundamental wave and the harmonic waves that have been as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed by using transformer equivalent circuits with the effect of load and simulated in time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 2.0kV. In high voltage circuit, capacitors are related to frequency band pass characteristics. Also, it is shown that the voltage of output pulse increases according to the growth of load.

Stand-Alone Pico-Hydro Generation System using a High-Efficiency IPM Synchronous Generator

  • Kurihara, Kazumi;Kubota, Tomotsugu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.121-125
    • /
    • 2014
  • This paper presents a successful stand-alone pico-hydro generation system using a high-efficiency interior permanent-magnet (IPM) synchronous generator. A 1-kW 4-pole V-type IPM generator with low voltage regulation is used for laboratory test in stand-alone hydro energy conversion system. It has been found from experimental results that the constant output voltage is supplied stably by the proposed system under wide speed range.

승압형 컨버터의 직렬 배열에 의한 펄스전압 발생회로 (Pulse Generator Using Series-Connected Boost Converter)

  • 백주원;유동욱;김태진;류명효;조기연;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권4호
    • /
    • pp.170-176
    • /
    • 2003
  • This paper introduces an improved pulse generator using power semiconductors and L-C circuit. The proposed circuit consists of the series connected boost converter structure. In the presented circuits, high voltage pulse is generated by series-connection of capacitors and IGBTs. The charging of capacitors and voltage balance of IGBTs are obtained automatically. To verify the proposed circuit, 1.8㎸, 40A pulse generator is manufactured and tested.

터보 제너레이터의 시동 알고리즘 및 시동기 개발 (Development of the Starting Algorithm and Starter for Turbo Generator)

  • 노민식;박승엽
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.17-24
    • /
    • 2004
  • 터보 제너레이터의 시동기는 터보 샤프트 발전 시스템 시동기의 구성인 기어박스, DC 전동기, 저 전압 축전지를 대신하여 고속 발전기, 인버터 그리고 승압기로 구성된다. 터보 제너레이터는 시동 시 고속 회전이 요구되어 고속발전기는 수십 $\mu$Η의 낮은 누설 인덕턴스를 가지며, 인버터는 높은 전압의 DC link 전압이 필요하다. 본 연구에서는 시동기 구현을 위해 축전지 전압을 높은 전압으로 승압하는 대 용량 승압기를 개발하였다. 그리고 낮은 누설 인덕턴스를 갖는 전동기 권선에 높은 주파수의 전류 제어를 위해 정밀 고속 연산을 수행하는 인버터 드라이버의 설계와 안정된 점화를 위한 터보 제너레이터의 시동 알고리즘을 제안하였다. 또한 개발한 시동기로 터보 제너레이터의 시동을 수행하여 성능을 확인하였다.

전력용반도체 소자를 이용한 새로운 고전압 펄스발생회로 (High Voltage Pulse Generator using Power Semiconductor Switches)

  • 이영운
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.30-33
    • /
    • 2000
  • Using power semiconductor switches such as IGBTs diodes and L-C circuits novel repetitive impulse voltage generator is developed. In the presented circuits high voltage pulse is generated by series-connection of capacitors and IGBTs. The charging of capacitors and voltage balance of IGBTs is done automatically. To verify the proposed circuit 20kV, 300A pulse generator is manufactured and tested.

  • PDF