Development of high power impulse magnetron sputtering (HiPIMS) techniques

  • Lee, Jyh-Wei
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.3-32
    • /
    • 2016
  • High power impulse magnetron sputtering (HiPIMS) technique has been developed for more than 15 years. It is characterized by its ultra-high peak current and peak power density to obtain unique thin film properties, such as high hardness, good adhesion and tribological performance. However, its low deposition rate makes it hard to be applied in industries. In this work, the development of HiPIMS system and integration of radio frequency (RF) or mid-frequency (MF) power supplies were introduced. Effects of duty cycle and repetition frequency on the microstructure, mechanical property, optical and electrical properties of some binary, ternary and quarternary nitride coatings and oxide thin films were discussed. It can be observed that the deposition rate was effectively increased by the superimposed HiPIMS with RF or MF power. High hardness, good adhesion and sufficient wear resistance can be obtained through a proper adjustment of processing parameters of HiPIMS power system.

  • PDF

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터 (New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권10호
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment)

  • 강창원;최길수;이영상;김창욱;강대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard)

  • 강창원;최길수;이영상;강대수;김재철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

550W급 PDP용 고효율 전원 장치에 관한 연구 (A study on the high efficiency power supply for 550W class PDP)

  • 원기식;안태영;박노성;조인호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.459-462
    • /
    • 2005
  • Recently, the PDP is the most remarkable media for a next generation display device. But the PDP is a high power consumption device. It is to required a high efficiency power supply. We reported the experimental result the high efficiency PDP power supply for 550w class. The proposed converter is quasi-resonant flyback topology, it achieves soft-switching in the single-switch flyback converter. As a result, we realize to very high efficiency power supply for PDP of 95% at 400v dc input and 550Watt output.

  • PDF

한국형 고속전철 차량시스템의 개념설계 (The Conceptual Design of Korea High Speed Train System)

  • 김경택;정경렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.172-180
    • /
    • 1999
  • The major subject of this paper is to develop the concept fur a Korea high speed train system and recommend to train configuration. High speed train configurations are basically concerned traction power(train configurations with concentrated; CPT or distributed Power system: DPT) and train design(single car as compared with articulated bogies). The result of configuration, a advantages and disadvantaged were necessitated by different train configurations; -distributed underfloor power have an increased length for the seats by 15% as compared with the concentrated power trait - articulated trainsets are characterised by less of number of bogies and reduced values of mass, train resistance, noise and vibration. from the result, the optimized train concept combining high seat capacity per train length with low weight and train resistance is 400m long, single -floor train composed of two symmetrically arranged half trainsets. Therefore, at this work recommended distributed train system However, the final decision of Korea high speed train configuration was concentrated power train and articulated bogie system. The configuration of trainset was 20cars included 2 power cars, 4 motorized cars and 14 trailer cars.

  • PDF

고역률 단일 전력단 고주파 공진 AC-DC 컨버터의 특성해석 (A Characteristic Analysis of Single-Power-Stage High Frequency Resonant AC-DC Converter with High Power Factor)

  • 남승식;원재선;황계호;오경섭;박재욱;김동희;오승훈
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.372-380
    • /
    • 2004
  • 본 논문은 기존의 2개의 전력 처리단을 갖는 컨버터를 단일 전력단으로 구성하고, ZVS기법을 이용한 고역률 단일전력단 고주파 공진 AC-DC 컨버터를 제안하고 있다. 입력단에 승압형 역률개선 인덕터를 연결하여 일정 듀티비와 가변 스위칭 주파수로 입력전류를 불연속 모드로 제어함으로써 입력 역률을 개선하는 것이 가능하였다. 종래의 2개 전력 처리단을 가지는 컨버터의 경우 역률 제어용 스위치가 별도로 필요하지만 전력 처리단을 하나로 단일화 시키므로써 컨버터의 구성이 간략화 되어져, 비용의 저감과 신뢰성을 증가시킬 수 있는 등의 장점이 있다. 본 연구는 고역률 단일전력단 AC-DC 컨버터의 동작원리와 무차원화 파라미터를 이용한 특성평가를 범용성 있게 행하여, 특성평가에서 산출한 특성값을 기초로 하여 실험장치를 제작하였으며, 실험치와 이론치를 비교ㆍ검토하여 제안 회로의 특성해석의 정당성을 입증하고 있다.

Correlation between Uni-standing Balance Ability, Jumping Ability, and Anaerobic Lower Extremity Muscle Power of High School Taekwondo Players

  • Jeong, Mo-beom
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권4호
    • /
    • pp.457-462
    • /
    • 2021
  • Objective: This study analyzed the correlation between uni-standing balance ability, jumping ability, and anaerobic lower extremity power of high school Taekwondo players. Design: Cross-sectional study Methods: Two high schools recruited 36 taekwondo players, but 5 were dropped due to personal circumstances and preparations for the tournament, so the number was counted as 31. In order to test uni-standing balance ability, the Romberg test was performed using Biorescue to measure the sway area. In order to test jumping ability, standing long jump and standing highjump were measured. For anaerobic lower extremity muscle power test, the peak power and average power were measured through 30-second pedaling using a Wingate system bicycle. Results: Participants did not show any correlation with other measures in the uni-standing balance ability test (p>0.05). Looking at the correlation in the standing long jump, standing high jump (r=0.892, p<0.05), anaerobic peak power (r=0.698, p<0.05), anaerobic average leg power (r=0.662, p<0.05) showed a positive correlation. Looking at the correlations in the standing high jump, anaerobic peak power (r=0.663, p<0.05), anaerobic average power (r=0.697, p<0.05) showed a positive correlation. Looking at the correlation in the anaerobic peak power, average power (r=0.785, p<0.05) showed a positive correlation. Conclusions: This study shows that balance ability and anaerobic leg strength are independent of each other. The results of this study can be used as basic data for the training plan of high school taekwondo players in the future.

저출력 및 고출력 SOEC 시스템의 경제성 분석 비교 (Economic Analysis and Comparison between Low-Power and High-Power SOEC Systems)

  • 뚜안앵;김영상;이동근;안국영;배용균;이상민
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.707-714
    • /
    • 2022
  • Hydrogen production using solid oxide electrolysis cells (SOEC) is a promising technology because of its efficiency, cleanness, and scalability. Especially, high-power SOEC system has received a lot of attention from researchers. This study compared and analyzed the low-power and high-power SOEC system in term of economic. By using revenue requirement method, levelized cost of hydrogen (LCOH) was calculated for comparison. In addition, the sensitivity analysis was performed to determine the dependence of hydrogen cost on input variables. The results indicated that high-power SOEC system is superior to a low-power SOEC system. In the capital cost, the stack cost is dominant in both systems, but the electricity cost is the most contributed factor to the hydrogen cost. If the high-power SOEC system combines with a nuclear power plant, the hydrogen cost can reach 3.65 $/kg when the electricity cost is 3.28 ¢/kWh and the stack cost is assumed to be 574 $/kW.