• Title/Summary/Keyword: High Line

Search Result 8,107, Processing Time 0.53 seconds

A Study on Characteristics of Coupled Line Employing Periodical Ground Structure on GaAs MMIC (GaAs MMIC상에서 주기적 접지구조를 가지는 결합선로의 절연특성에 관한 연구)

  • Kim, Se-Ho;Kang, Suk-Youb;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.159-165
    • /
    • 2009
  • In this study, using a periodical ground structure(PGS) on GaAs monolithic microwave integrated circuit(MMIC), transmission line with a high isolation characteristic was developed for application to compact signal/bias lines of highly integrated MMIC. And the origin of the high isolation characteristic was theoretically investigated. The high isolation characteristic was originated from a resonance between adjacent microstrip lines employing PGS. With only a spacing of $20{\mu}m$, the coupled microstrip line employing PGS showed an isolation value of -47 dB at 60 GHz. The frequency range for high isolation was easily controlled by changing the PGS structure. Above results indicate that microstrip lines employing PGS are very useful for application to compact signal/bias lines of highly integrated MMIC requiring a high isolation characteristics between lines. In addition, equivalent circuit employing closed-form equation for the coupled line with PGS was also extracted.

Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

An Experimental Study on the Correlation between Span Types and the Contact Force of the Pantograph for High-speed Train (경간형식과 고속열차 판토그라프 접촉력 특성의 상호관계에 대한 시험적 고찰)

  • Kim Young-Guk;Mok Jin-Yong;Lee Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.5
    • /
    • pp.398-404
    • /
    • 2005
  • In this paper, we introduce the on-line test of the current collection characteristics for HSR 350x(Korea High Speed Train project) that have been performed in the Kyoung-bu high-speed line since 2002. Through the analysis of measured data during on-line test, the variation trend of contact force between pantograph and contact wire of catenary according to the span type, the track conditions and driving patterns is reviewed. In order to analyze the variation trend of contact force, we have checked the span type of catenary in KP 24 - 125 out of Kyoung-bu high speed line and obtained the statistical processing result per each span type. This study shows that the track conditions do not affect on the dynamic performance between pantograph and contact wire catenary, and the span type and the driving pattern are important factors in determining the good interaction between them.

Examination on the variation of ride comfort for korean high speed train through on-line test (시운전 시험을 통한 한국형 고속열차의 승차감 변화추세에 관한 연구)

  • Kim, Young-Guk;Mok, Jin-Yong;Kim, Seog-Won;Park, Chan-Kyeong;Kim, Ki-Hwan;Park, Tae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.144-149
    • /
    • 2005
  • In this paper, we introduce the variation of ride characteristics for HSR 350x(Korea High Speed Train project) through on-line test during about 3 years. The concept of term "ride comfort" is equivocal. Generally it is evaluated as the vehicle vibration. The ride comfort for HSR 350x has been assessed by statistical method according to UIC 513R. The testing results show that HSR 350x has no problems from the viewpoint of the comfort ride on the high speed line and conventional line and that 1st and 2nd suspensions play an important role in the ride characteristics for high speed train.

Study on longitudinal variation of subcooling with high elevated liquid line in a modular heat pump system (모듈형 동시냉난방 열펌프의 장배관/고낙차에 따른 액선 과냉도 변화에 대한 연구)

  • Shin, Kwang-Ho;Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang;Park, Sung-Ryung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1255-1260
    • /
    • 2008
  • This study is simulation of high elevated liquid line of a modular heat pump system to observe longitudinal subcooling variation. In a high elevated tube, subcooled refrigerant(R410A) through a condenser changes its states by heat transfer with surrounding air and by pressure drop from elevation. In this study, the liquid line was simulated through correlations of heat transfer and pressure drop for the variation from single-phase into two-phase flow. Pressure drop, heat transfer rate and vapor quality were calculated as key parameters. Two-phase turning heights and variations of the key parameters were confirmed from the simulation. As a result, high elevation of liquid line has great influence on upward flow, which requires additional equipment to compensate the variation.

  • PDF

Noise Characteristics of High Speed Railway(KTX) Running on Conventional Line (고속철도의 기존선 통과시 소음특성에 관한 연구)

  • Cho Jun-Ho;Lee Chan-Woo;Kim Jae-Chul;Choi Sung-Hoon;Han Hwan-Su
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.399-404
    • /
    • 2004
  • When high speed train runs on heavy curvature section of conventional line, squeal noise emitted from the railroad and wheel. This noise is very unpleasant to the near habitant. In this study, the characteristics and the countermeasures of the squeal noise of high speed train running on the conventional line was investigated.

  • PDF

A study of the harmonics evaluation in the test track of Korea High Speed Rail (경부고속철도 시험선구 고조파 예측에 관한 연구)

  • 김길상;오광해;권삼영;이태형
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.241-248
    • /
    • 1998
  • The purpose of this study is to evaluate the harmonics generated from Korea High Speed Rail's trainset and to analyze the effect on the KEPCO power system. This study focuses on the test track of the high speed rail and analyzes 154㎸ transmission line, scott transformer, autotransformer and 27,5㎸ line. The trainset is modeled as a harmonic source attached to the catenary line of the test track. Then, harmonic distortion is calculated. This distortion is compared with the KEPCO's regulations in relation to harmonic.

  • PDF

Response Characteristics of Metal Belt CVT Vehicle with Electronic Controlled Line Pressure (라인압력제어 전자화 CVT 차량의 응답 특성)

  • 송한림;김정철;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.191-202
    • /
    • 1998
  • An electronic-hydraulic controlled line pressure system was suggested based on the mechanical controlled CVT base model. As a high level control strategy, a 3-D optimal line pressure map was obtained considering the driver's desire, driving conditions. Also, PID type low level controller was designed. Using the high level control strategy and the dynamic models of the base model CVT with electronic controlled line pressure system, performance simulations were carried out. It is seen from the simulation results that fuel economy of the electronic controlled strategy keeps the line pressure low, which results in the improved efficiency of the hydraulic system.

  • PDF

Design of a laboratory-scale superconducting DC transmission line (모델급 초전도 직류 송전 선로의 설계)

  • Kim, Sung-Kyu;Dinh, Minh-Chau;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1102-1103
    • /
    • 2015
  • The researchers worldwide have been trying to apply high temperature superconducting wire for power system devices. High voltage direct current (HVDC) transmission system has been used for bulk and long-distance power transmission. The authors designed a laboratory-scale superconducting DC transmission line to investigate its applicability to an HVDC system. The superconducting DC transmission line was simulated in connection to a laboratory-scale HVDC system using PSCAD/EMTDC. The operating characteristics of the superconducting DC transmission line connected to HVDC system and the effects of the superconducting DC transmission line on HVDC system were analyzed and compared with the results of a conventional DC transmission line. The results of operating characteristics for the superconducting DC transmission line were discussed in detail.

  • PDF

Research of High data rate Power-Line Communication with Characteristics Analysis (전력선 채널 특성을 통한 고속 데이터 통신 방법 연구)

  • Kim, D.S.;Seo, J.W.;Kim, D.H.;Choi, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2499-2501
    • /
    • 2001
  • Today many researches are accomplished for power line communication. But It is very dangerous to communicate with devices using power line. Because power line is an candidate to cope with the existing communication channels. So It is need to be measured the properties of power line as communication channels, before successful communication system is possible. In this paper, we re-analysis the characteristics of power line and suggest an implementation technique for the high-data-rate power line communication modem.

  • PDF