• Title/Summary/Keyword: High Line

Search Result 8,123, Processing Time 0.038 seconds

Graphical Modeling for Operational Scheme of Current Differential Relay for Transmission Line Protection (송전선 보호용 차동전류 계전기의 동작원리에 대한 그래픽 표현)

  • Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1407-1409
    • /
    • 1999
  • Distance relay is being used for transmission line protection. Recently, current differential relay is used with high reliability in power system. This kind of relay is reported that it has a reliable detection ability, even so high impedance faults take place in transmission line. Therefore it is expected to use and expand widely in many utilities. Tripping of the relay is decided according to the difference between differential and restraint current. However the tripping criterion can be changed by the manufacturers. This paper presents an operational scheme of current differential relay for transmission line protection with graphical model. It is developed for educational purpose for students interesting in power system and protection engineer in utility. MATLAB is used to establish the models.

  • PDF

Development of Floating Power Supply for Current Measurement System of High Voltage Power Line

  • Oota, Ichirou;Hattori, Hiroaki;Nishiyama, Eiji;Matsuda, Toyonori;Kawano, Mitsunori;Kuwanami, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.88.5-88
    • /
    • 2002
  • A new floating power supply for the current measurement system of a high voltage power line is developed. It is confirmed that, the current measurement system can stably transfer the signal of the power line current about 50 - 300 A by using the proposed power supply. The excellent characteristics are obtained by the steady-state and transient experiments of the proposed circuit. $\textbullet$ The right figure shows the external view of the trial measurement system for 6.6 kV. In order to see the inside, 120 degrees of the insulator is cut. The toroidal coil for the power supply and the Rogowskii coil for the current sensor are both divided into two and fixed on the power line as...$\textbullet$ The proposed circuit can supply +5V and -5V voltages without using a solar cell and/or a battery.

  • PDF

Characteristics of the Voltages between the Communication Lines and Ground Induced by the Adjacent Artificial High-Voltage or Current ELF Source

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong;Eun, Chang-Soo;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.4
    • /
    • pp.175-181
    • /
    • 2009
  • The measurements were performed to verify experimentally that the voltage arising on a telecommunication line by a power line is due to the induction phenomena because there has been an opinion that the arising voltage on a telecommunication line is not by induction, but by other causality. The voltage appeared on the telecommunication line by way of an electric field or magnetic field generated by the source apparatus that had been artificially made to provide intentional constant high-voltage or current in ELF, that is, 60 Hz as an emulated commercial power.

Investigation on Grain Image Visulalization and Color Sorting Technique (색채선별기 곡물 이미지 가시화 및 선별기법에 관한 연구)

  • Lee, Choon-Young;Yan, Lei;Lee, Sang-Ryong;Par, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.2
    • /
    • pp.20-27
    • /
    • 2008
  • The color sorting technique utilizing the image processing method is very applicable tool to analyze motion of a free-falling object in many agricultural and industrial research fields. In the present study, we have developed an image processing system and algorithm to sort good quality rice grains effectively from the bad ones. The system employs a high speed rate line-scan CCD camera with 2K-pixels and worked with a high speed DSP and FPGA in-line. It can accumulate acquired line-scan image data and visualize each grain image clearly. As a result, we can easily calculate the number of pixels occupied by grain(=grain size), gray level and its correct position by visualizing grain images rapidly.

SPECTRAL BEHAVIORS OF Hβ LINE OF CH CYGNI IN A QUIESCENT PHASE

  • YOO KYE HWA;KIM KANG MIN;LEE BYUNG CHUL;YOON TAE SEOG;LEE JUNG AE
    • Publications of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.21-25
    • /
    • 2004
  • We analyzed the high resolution H,6 line spectra of CH Cygni obtained at the Bohyunsan Astronomical Observatory (BOAO) on April 2004. The temporal changes in the $H\beta$ line profiles are reported. We obtained the equivalent widths of the Gaussian components. Using this we estimated the length of the gaseous nebula which emits the $H\beta$ line and the mass loss rate from the star.

Statistical Moment Analysis of the Strong DLA Profiles

  • Chang, Seok-Jun;Bach, Kiehunn;Lee, Hee-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.35.3-35.3
    • /
    • 2018
  • Incorporating the fully quantum mechanical computation of scattering cross-section and statistical moment analysis of absorption profiles, we investigate the Lyman line asymmetry of extremely high column density systems. Recent high redshift observations detected strong damped Lyman alpha systems (DLAs) whose column density is larger than N_HI ~ [10]^21.3 cm^(-2). Absorption profiles of these DLAs are characterized by the broad and asymmetric damping wing. For accurate description of radiation damping, the second-order time-dependent perturbation theory is adopted. To quantitatively address line asymmetry, we define a distribution function for each Lyman line, and compute statistical moments (mean, standard deviation, skewness and kurtosis) regarding column densities N_HI > [10]^18 cm^(-2). In this work, we present statistical properties of the intrinsic line profiles, and compare them with the Lorentzian cases.

  • PDF

Twisted Differential Line Structure on High-Speed Printed Circuit Boards to Enhance Immunity to Crosstalk and External Noise

  • Kam, Dong-Gun;Kim, Joung-Ho
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Differential signaling has become a popular choice for high-speed interconnection schemes on Printed Circuit Boards (PCBs), offering superior immunity to external noise. However, conventional differential transmission lines on PCBs have problems, such as crosstalk and radiated emission. To overcome these, we propose a Twisted Differential Line (TDL) structure on a multi-layer PCB. Its improved immunity to crosstalk noise and the reduced radiated emission has been successfully demonstrated by measurement. The proposed structure is proven to transmit 3 Gbps digital signals with a clear eye-pattern. Furthermore, it is subject to much less crosstalk noise and achieves a 13 dB suppression of radiated emission. Index Terms - Twisted Differential Line, Differential Signaling, Crosstalk, Radiated Emission, Transmission Line, Twisted Pair

A Study on the Auto-Reclose Dead lime Control using Neural Network based On-line Transient Stability Assessment (신경회로망을 이용한 On-line 과도안정도 평가에 의한 자동재폐로 무전압 시간제어 연구)

  • Kim, Il-Dong;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.131-136
    • /
    • 1995
  • This paper presents a functional ability improvement of auto-reclosing relay in the power transmission line protection. When the high speed auto-reclosing is successful, Auto-reclosing is practically valuable to improve the transient stability limit of a power system, but it is fail due to surviving fault, both electrical and mechanical stresses can result on the transformers and turbine-generator. It is true that the longer dead time of the reclosing relay gives the higher rate of successful reclosing, On the other hand, the power system does not always need high speed reclosing because of enough stability margin. This paper proposed "stability margin based dead time reclosing" in order to decrease not only the rate of unsuccessful reclosing, but the possibility of the harmful stress also. On-line transient stability assessment using artificial neural network, for implementing the proposed scheme, has studied and tested with resonable results.

  • PDF

Implementation of Control System for Remote Load using Power line Communication (전력선 통신을 이용한 원격 부하제어 시스템의 구축)

  • Kim Ho;Lee Won-Sun;Jeon Hee-Jong;Park Jong-chan
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.685-688
    • /
    • 2002
  • This paper deals with new scheme of remote load control management system with communication from RCU to controller using power line Power line communication is useful for economical data link but various problems and limitations are caused in using power lines for communications channel. A power line is not so good in the commercial electrical power, and its load noise and high frequency noise are so much. To decrease these noise, we used the FSK(Frequency Shift Keying) modulation method. The experimental results show that the proposed system in this paper is compatible with the conventional system with low cost and the feasibility is very high for new or remodeling plant.

  • PDF

Electromagnetic Behavior of High -$T_c$ Superconductors underthequenchstate -

  • 정동철;최효상;황종선;윤기웅;한병성
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.183-187
    • /
    • 2002
  • In this paper we analyzed the electromagnetic behavior of high $-T_{c}$ superconductor under the quench state using finite element method. Poisson equation was used in finite element analysis as a governing equation and was solved using algebra equation using Gallerkin method. We first investigate d the electromagnetic behavior of U-type superconductor. Finally we applied our analysis techniques to 5.5 kVA meander-line superconducting fault current limiters (SFCL) which are currently developed by many power-system researcher in the world. Meshes of 14,600 elements were used in analysis of this SFCL. Analysis results show that the distribution of current density was concentrated to inner curvature in meander-line type-superconductors and maximum current density 14.61 $A/\m^2$ and also maximum Joule heat was 6,420 W/㎥. We concluded that this meander line-type SFCL was not pertinet fur uniform electromagnetic field distribution.n.

  • PDF