• 제목/요약/키워드: High Frequency Operating

검색결과 1,091건 처리시간 0.036초

고주파 인버터의 특성해석 및 출력주파수 추종제어 (The characteristic analyses and output frequency tracking control of a high frequency inverter)

  • 이종무;김영석;조기연
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.597-602
    • /
    • 1987
  • This paper proposes a voltage-fed high frequency resonant inverter having variable voltage variable frequency(VVVF) control function. VVVF control is performed by PWM-TRC method in the boost type chopper and PFM-TRC method in the high frequency resonant inverter. This circuit is suitable for induction heating and melting power supply in industry. The operating characteristics of this inverter are discussed from a theoretical point of view. The results of operating characteristic analyses are given leading to complete designing data.

  • PDF

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계 (Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter)

  • 백승혁;김성민;이재홍;이승환
    • 전력전자학회논문지
    • /
    • 제26권6호
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

유도 가열용에 사용되어지는 새로운 부분공진형 영전압 스위칭 PWM 고주파 인버터 (New Partial Resonant Zero Voltage Switching PWM High Frequency Inverter using Induction Heating)

  • 정영수;문상필;박한석
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.261-266
    • /
    • 2015
  • This paper presents a newly proposed prototype of voltage-fed half-bridge partial resonant zero voltage switching PWM inverter operating at a constant frequency variable power regulation scheme, which is more suitable and acceptable for induction heated(IH) cooking appliances. This application-specific high frequency inverter circuit topology using a new generation specially-designed IGBTs can operate under a principle of a fixed frequency ZVS-PWM strategy. The operating principle of a new partial resonant inverter circuit is described on the basis of its computer-aided simulation analysis, its including steady-state operating characteristics.

스터링 냉동기의 선헝압축기 운전특성에 관한 수치해석적 연구 (Numerical Analysis of Performance of Linear Compressor for the Stilting Cryocooler)

  • 홍용주;박성제;김효봉;염한길;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.58-62
    • /
    • 2002
  • The purpose of this study is to analyze the charging gas effect on the resonance and performance characteristics of the linear compressor for small scale FPFD Stirling refrigerator. To ensure high performance of FPFD type Stirling refrigerator, the operating frequency of the refrigerator should be around the natural frequency of compressor. The gas spring effect which is induced from Pressure change in cylinder due to motion of pistons has significant effect on the natural frequency of the compressor. The numerical results show the linear compressor has high natural frequency when the charging pressure of working fluid is high and the stroke of compressor, current, input power and efficiency of compressor were shown with different operating conditions.

DRAM 패키지의 고주파 잡음 특성 (The Characteristics of operating noises in the FBGA packages at high frequency)

  • 김준일;지용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.487-488
    • /
    • 2006
  • In this paper, we analyzed the FBGA packages operating in high speeds and high frequency rates for DRAM. Using 3D simulations, we could extract s-parameters of packages. We realize that the proposed FBGA package does not operate properly at 3Gbps bacause the FBGA package have delta-I noise($V_{{\Delta}I-peak}$) of 132.0mV and crosstalk of 300mV, which is 25% of the operating clock level.

  • PDF

Advanced Induction Heating Equipment using Dual Mode PWM-PDM Controlled Series Load Resonant Tank High Frequency Inverters

  • Fathy, Khairy;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.246-256
    • /
    • 2007
  • In this paper, a novel type auxiliary active edge resonant snubber assisted zero current soft switching pulse modulation Single-Ended Push Pull (SEPP) series load resonant inverter using IGBT power modules is proposed for cost effective consumer high-frequency induction heating (IH) appliances. Its operating principle in steady state is described by using each switching mode's equivalent operating circuits. The new multi resonant high-frequency inverter with series load resonance and edge resonance can regulate its high frequency output power under a condition of a constant frequency zero current soft switching (ZCS) commutation principle on the basis of the asymmetrical pulse width modulation (PWM) control scheme. Brand-new consumer IH products using the proposed ZCS-PWM series load resonant SEPP high-frequency inverter using IGBTs is evaluated and discussed as compared with conventional high-frequency inverters on the basis of experimental results. In order to extend ZCS operation ranges under a low power setting PWM as well as to improve efficiency, the high frequency pulse density modulation (PDM) strategy is demonstrated for high frequency multi-resonant inverters. Its practical effectiveness is substantially proved from an application point of view.

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

Redundant Multi-Valued Logic을 이용한 고속 및 저전력 CMOS Demultiplexer 설계 (Design of a High Speed and Low Power CMOS Demultiplexer Using Redundant Multi-Valued Logic)

  • 김태상;김정범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.148-151
    • /
    • 2005
  • This paper proposes a high speed interface using redundant multi-valued logic for high speed communication ICs. This circuit is composed of encoding circuit that serial binary data are received and converted into parallel redundant multi-valued data, and decoding circuit that convert redundant multi-valued data to parallel binary data. Because of the multi-valued data conversion, this circuit makes it possible to achieve higher operating speeds than that of a conventional binary logic. Using this logic, a 1:4 demultiplexer (DEMUX, serial-parallel converter) IC was designed using a 0.35${\mu}m$ standard CMOS Process. Proposed demultiplexer is achieved an operating speed of 3Gb/s with a supply voltage of 3.3V and with power consumption of 48mW. Designed circuit is limited by maximum operating frequency of process. Therefore, this circuit is to achieve CMOS communication ICs with an operating speed greater than 3Gb/s in submicron process of high of operating frequency.

  • PDF

Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

  • Chaudhari, Madhuri A.;Suryawanshi, Hiralal M.;Kulwal, Abhishek;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.60-73
    • /
    • 2008
  • In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.