• Title/Summary/Keyword: High Dose Rate

Search Result 896, Processing Time 0.04 seconds

Pharmacological Actions of New Woohwangchungsimwon Liquid on Cardiovascular System (신우황청심원액의 심혈관계에 관한 약효연구)

  • 조태순;이선미;김낙두;허인회;안형수;박대규
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.390-401
    • /
    • 1997
  • In order to investigate the pharmacological properties of New Woohwangchungsimwon Liquid (NCL), effects of Woohwangchungsimwon Liquid (CL) and NCL were compared. In isolated rat aorta, NCL and CL showed the relaxation of blood vessels in maximum contractile response to phenylephrine (10$^{-6}$ M) without regard to intact endothelium or denuded rings of the rat aorta. Furthermore, the presences of the inhibitor of NO synthase and guanylate cyclase did not affect the relaxation of NCL and CL. NCL and CL inhibited the vascular contractions induced by acetylcholine, prostaglandin endoperoxide or peroxide in a dose-dependent manner. In conscious spontaneously hypertensive rats (SHRs), NCL and CL significantly decreased heart rate. NCL and CL, at high doses, had a negative inotropic effect that was a decrease of LVDP and (-dp/dt)/(+dp/dt) in the isolated perfused rat hearts, and also decreased the contractile force and heart rate in the isolated rat right atria. In excised guinea-pig papillary muscle, NCL and CL had no effects on parameters of action potential at low doses, whereas inhibited the cardiac contractility at high doses. These results suggested that NCL and CL have weak cardiovascular effects with relaxation of blood vessels and decrease of heart rate, and that this effect is no significant differences between two preparations.

  • PDF

Pharmacological Actions of New Wonbang Woohwangchungsimwon Liquid on Cardiovascular System (신원방우황청심원액의 심혈관계에 관한 약효)

  • 조태순;이선미;김낙두;허인회;안형수;권광일;박석기;심상호;신대희
    • Biomolecules & Therapeutics
    • /
    • v.7 no.1
    • /
    • pp.66-78
    • /
    • 1999
  • In order to investigate the pharmacological properties of New Wonbang Woohwangchungsimwon Liquid (NSCL), effects of Wonbang Woohwangchungsimwon Liquid (SCL) and NSCL were compared. In isolated rat aorta, NSCL and SCL showed the relaxation of blood vessels in maximum contractile response to phenylephrine (10$^{-6}$ M) regardless to intact endothelium or denuded rings of the rat aorta. Furthermore, the presences of the inhibitor of NO synthase and guanylate cyclase did not affect the relaxing effect of NSCL and SCL. NSCL and SCL inhibited the vascular contractions induced by acetylcholine, prostaglandin endoperoxide or peroxide in a dose-dependent manner. In conscious spontaneously hypertensive rats (SHRs), NSCL and SCL significantly decreased heart rate. NSCL and SCL, at high doses, had a negative inotropic effect that was a decrease of left ventricular developed pressure and (-dp/dt)/(+dp/dt) in the isolated perfused rat hearts, and also decreased the contractile force and heart rate in the isolated rat right atria. In excised guinea-pig papillary muscle, NSCL and SCL had no effects on parameters of action potential such as resting membrane potential, action potential amplitude, APD$_{90}$ and V$_{max}$ at low doses, whereas inhibited the cardiac contractility at high doses. These results suggested that NSCL and SCL have weak cardiovascular effects with relaxation of blood vessels and decrease of heart rate, and that this effect is no significant differences between cardiovascular effects of two preparations.s.

  • PDF

Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas (자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교)

  • Chung, Eun-Ji;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.396-404
    • /
    • 2002
  • Purpose : Many papers support a correlation between rectal complications and rectal doses in uterine cervical cancer patients treated with radical radiotherapy. In vivo dosimetry in the rectum following the ICRU report 38 contributes to the quality assurance in HDR brachytherapy, especially in minimizing side effects. This study compares the rectal doses calculated in the radiation treatment planning system to that measured with a silicon diode the in vivo dosimetry system. Methods : Nine patients, with a uterine cervical carcinoma, treated with Iridium-192 high dose rate brachytherapy between June 2001 and Feb. 2002, were retrospectively analysed. Six to eight-fractions of high dose rate (HDR)-intracavitary radiotherapy (ICR) were delivered two times per week, with a total dose of $28\~32\;Gy$ to point A. In 44 applications, to the 9 patients, the measured rectal doses were analyzed and compared with the calculated rectal doses using the radiation treatment planning system. Using graphic approximation methods, in conjunction with localization radiographs, the expected dose values at the detector points of an intrarectal semiconductor dosimeter, were calculated. Results : There were significant differences between the calculated rectal doses, based on the simulation radiographs, and the calculated rectal doses, based on the radiographs in each fraction of the HDR ICR. Also, there were significant differences between the calculated and measured rectal doses based on the in-vivo diode dosimetry system. The rectal reference point on the anteroposterior line drawn through the lower end of the uterine sources, according to ICRU 38 report, received the maximum rectal doses in only 2 out of the nine patients $(22.2\%)$. Conclusion : In HDR ICR planning for conical cancer, optimization of the dose to the rectum by the computer-assisted planning system, using radiographs in simulation, is improper. This study showed that in vivo rectal dosimetry, using a diode detector during the HDR ICR, could have a useful role in quality control for HDR brachytherapy in cervical carcinomas. The importance of individual dosimeters for each HDR ICR is clear. In some departments that do not have the in vivo dosimetry system, the radiation oncologist has to find, from lateral fluoroscopic findings, the location of the rectal marker before each fractionated HDR brachytherapy, which is a necessary and important step of HDR brachytherapy for cervical cancer.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Gamma Radiation Sensitivity and Quantitative Characters in M1 Generation of Heteropappus hispidus (Thunb.) (갯쑥부쟁이(Heteropappus hispidus (Thunb.))의 감마방사선 감수성과 M1 세대 형질변동 특징)

  • Oh, Byung-Kwon;Hong, Kyung-Ae;Song, Sung-Jun;Lee, Sun-Joo;Lee, Young-Il;U., Zang-Kual
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.294-299
    • /
    • 2003
  • The seeds of naturally growing Heteropappus hispidus (Thunb.) were treated by nine different doses (0, 10, 20, 40, 80, 120, 160, 200, 300, 400 Gy) of gamma rays to investigate their germination rate and to quantity the characteristics of their germinated plants as like as leaf appearance and length, the formation rate of anthocyanin color in stem 30 days after germination, the formation rate of rosette leaf and multi-shoot, the flowering and seed-bearing, and shoot length. The germination rate at least up to 120Gy was not greatly affected but was rapidly decreased at over 160Gy. It seemed that lethal dose ($LD_{50}$) of germination was 160Gy. The leaf appearance and growth was also inhibited, but the formation rate of anthocyanin color in the flower stem was enhanced up to 30% with dose. The rosette plants were observed in plants irradiated with higher than 40Gy. Multi-shoots were developed over 80Gy. For a short shoot length and bundle of thin stem, it was considered that they can be selected as the potential pot flower plants, through genetic fixation. In particular, it was suggested that the formation of anthocyanin color in flower stem, rosette and multi-shoot plants induced by the high dose of gamma rays could be utilized as the morphological markers for the mutant selection of Heteropappus hispidus (Thunb.).

Real Time On-line Quality Assurance System for HDR Brachytherapy (고선량률 근접 방사선 치료를 위한 실시간 온-라인 정도 관리(QA) 시스템 개발)

  • Lee Su Jin;Lee Re Na;Yi Byang Yang;Lim Sang Waak;Choi Jin Ho
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.156-160
    • /
    • 2004
  • An essential quality assurance (QA) procedure in high dose rate (HDR) remote after-loading brachytherapy is that of the verification of the Ir-192 HDR source positioning accuracy. A number of methods using mechanical rulers or autoradiograph and video cameras have been reported to check the positional error of the Ir-192 source. In this study, the feasibility of a CMOS (Complementary Metal Oxide Semiconductor) PC camera, with a fluorescent screen, was investigated. The agreement between the planned and measured dwell position was better than 1 mm and dwell times better than 0.4 sec. Our results indicate that the CMOS PC camera system could be used as a QA tool for the on-line determination of the source position and dwell time.

  • PDF

Transcatheter Irradiation of Advanced Extrahepatic Biliary Tract Carcinoma (진행된 담도암의 경관조사)

  • Kim Kyeoung Ae;Kim Sung Kyu;Shin Sei One;Kim Myung Se;Song Sun Kyuo;Kwon Koing Bo
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.173-176
    • /
    • 1987
  • Carcinoma of extrahepatic biliary tract is slow growing tumor but curative resection is rarely successful. Radiation therapy has been introduced for enhancing palliation and possible longterm survival. We treated a case of advanced extrahepatic biliary tract carcinoma with high dose rate remote afterloading system through T-tube as a initial irradiation postoperatively. We hope that this treatment may affect not only ennancing palliation and better quality of life but also in local tumor control.

  • PDF

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

X-Ray Diffraction line profile analysis of defects and precipitates in high displacement damage neutron-irradiated austenitic stainless steels

  • Shreevalli M.;Ran Vijay Kumar;Divakar R.;Ashish K.;Padmaprabu C.;Karthik V.;Archna Sagdeo
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.114-122
    • /
    • 2024
  • Irradiation-induced defects and the precipitates in the wrapper material of the Indian Fast Breeder Test Reactor (FBTR), SS 316 are analyzed using the synchrotron source-based Angle Dispersive X-Ray Diffraction (ADXRD) technique with X-rays of energy 17.185 keV (wavelength ~0.72146 Å). The differences and similarities in the high displacement damage samples as a function of dpa (displacement per atom) and dpa rate in the range of 2.9 × 10-7- 9 × 10-7 dpa/s are studied. Ferrite and M23C6 are commonly observed in the present set of high displacement damage 40-74 dpa SS 316 samples irradiated at temperatures in the range of 400-483 ℃. Also, the dislocation density has increased as a function of the irradiation dose. The X-ray diffraction peak profile parameters quantified such as peak shift and asymmetry show that the irradiation-induced defects are sensitive to the dpa rate-irradiation temperature combinations. The increase in yield strength as a function of displacement damage is also correlated to the dislocation density.