• Title/Summary/Keyword: Heterophoria test

Search Result 15, Processing Time 0.03 seconds

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Investigation of the horizontal heterophoria measurement at distance by various testing method (사위검사 방법의 차이에 따른 원거리 수평사위 검사값 비교)

  • Sim, Hyun-Seog;Lee, Seang-Wook;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • To investigate the subjective refractive error with Von Graefe test. Maddox Rod test and polarizing lens test of Horizontal Heterophoria Measurement at distance on normal 109 subjects aged from 18 to 30 years old. The results were as follows: 1. Using Von Graefe Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 65% for exophoria and 20% for esophoria at distance. 2. Using Maddox Rod Horizontal Heterophoria Measurement, they were measured 14% for orthophoria, 57% for exophoria and 29% for esophoria at distance. 3. Using polarizing lens test of Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 72% for exophoria and 13% for esophoria at distance. 4. Each test average were $1.32{\Delta}BI$ for Von Graefe test, $0.88{\Delta}BI$ for Maddox Rod test and $1.76{\Delta}BI$ for polarizing lens test. 5. Patient's preference distribution were 44% for Von Graefe test, 28% for Maddox Rod test and 28% for polarizing lens test.

  • PDF

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

The Examination of Refractive Correction and Heterophoria and Monocular Pupillary Distance on Myopic Elementary School Children Wearing Glasses in Gwangju City (광주지역 근시안경 착용 초등학생의 굴절상태와 사위 및 단안PD에 대한 조사)

  • Hwang, Kwang-Ha;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: This study was designed to investigate the condition of refractive correction and heterophoria and monocular pupillary distance on myopic elementary school children wearing glasses in Gwangju city. Methods: Subjective refraction and objective refraction were examined after investigating heterophoria and monocular pupillary distance on 145 (290eye) elementary school children wearing myopia-corrected glasses. Results: 1. Anisometropia > 2.00 D was present in 4 children (3%). 2. 9 anisometropia (47%) were present in 19 undercorrected visual acuity boy wearers. and 16 anisometropia (64%) were present in 25 undercorrected visual acuity girl wearers. 3. Among the 67 myopic glasses boy wearers, the distance between optical centers was coincided with the pupillary distance in 30% (Oculus Uterque), and discrepant in 70% (Oculus Uterque). Among the 78 myopic glasses girl wearers, the distance between optical centers was coincided with the pupillary distance in 23% (Oculus Uterque), and discrepant in 77% (Oculus Uterque). The mean optical center distance was longer than the pupillary distance on both boy and girl wearers 4. The result of measured heterophoria revealed 14% for orthophoria, 63% for exophoria, 23% for esophoria at far distance and 10% for orthophoria, 76% for exophoria, 14% for esophoria at near distance. Conclusions: Correct refractive test and monocular pupillary distance must be examined because incorrect refractive test and pupillary distance induce asthenopia and heterophoria.

  • PDF

The Study on the Property of The Heterophoria and Fusional Reserve in Adults in Jeon-buk Area (전북지역 성인의 사위와 융합여력 특성에 관한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun Mi;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.661-666
    • /
    • 2013
  • The aim of this study was to evaluate the property of heterophoria and fusional reserve in Adults in Jeon-buk Area. We examined the corrected visual acuity, corrected refractive error, heterophoria and fusional reserve of 116 healthy myopes aged from 20 to 44 old who had no strabismus no ocular and phyisical diseases. Using Von Graefe test of horizontal heterophoria Measurement, we measured orthophoria(26.7%), exophoria(52.5%) and esophoria(20.7%) for at near distance. The subjects who had exophoria of 0-6${\Delta}$ in the range of normal state was 38.8%, while the subjects who had exophoria in the range of abnormal state was 61.2%. Reducing fusional reserve was associated with increasing phoria. We found a relationship between asthenopia and fusional reserve of heterophoria and considered that fusional reserve must be examined when we preserve for a patient with heterophoria. Furthermore, Gradient method AC/A ratio was found 4.03 and its relationship to refractive error could not be determined.

Time-dependent Changes of Ocular Functions after Alcohol Ingestion (알코올 섭취 후 시간경과에 따른 시 기능의 변화)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Lee, Sun Haeng;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.133-138
    • /
    • 2009
  • Purpose: This study was designed to investigate the changes of vision and ocular functions induced by increase of blood alcohol level. Methods: Blood alcohol level, vision, refractive errors, near point convergence, heterophoria, and relative convergence were measured at 1 h, 4 h, and 24 h after acute alcohol ingestion of 0.7 g per kg body weight. Results: At 1 h after alcohol ingestion, myopization and ocular functions which measured near point convergence, positive and negative convergences, and degree of heterophoria remarkedly worked a changes accompanied with the maximum value of blood alcohol level. But at 24 h after that, all of ocular functions were recovered to degree of 90~99% compared with non-alcoholic normal conditions. Conclusions: As the increase of blood alcohol level is able to induce the significant changes of visual acuity and ocular functions, opticians have to understand thoroughly the patient's conditions by alcohol ingestion before refractive test and ocular examinations.

  • PDF

The Analysis on Trend of Articles about Strabismus in Journal of Korean Medicine (국내 한의학 학술지에 게재된 사시 관련 논문들의 경향성 분석)

  • Kim, Young-Bin;Kwon, Kang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.34 no.1
    • /
    • pp.13-28
    • /
    • 2021
  • Objectives : Strabismus is a disease that can be observed and treated directly from the outside. Therefore, it is very important in Korean medicine ophthalmology in accessibility to treatment. This study is designed to investigate the trends of strabismus-related studies published in Journal of Korean medicine. Methods : 5 Internet databases were selected to search for the study subject. The following 9 keywords were used; Strabismus, Heterophoria, Binocular vision, Visual acuity, Diplopia, Paralytic, Cover test, Oculomotor nerve paralysis, Abducens nerve paralysis. Through this process, a total of 45 studies were found and analyzed into 5 categories ; publication year, publication journal, number of author, type of article, analyzation of case report. Results : There were 2 review articles, 1 original article and 42 case reports. 5 studies(11.1%) were published in 2004 year. Journal of Korean Oriental Medical Ophthalmology & Otolaryngology & Dermatology were the most common with 40%. The authors were often 2 and 3 (each 22.2%). In the case report study, the treatment period was most often 1-30 days (35.7%). Conclusions : 42 studies were on paralytic strabismus and 1 study was on paralytic and non-paralytic strabismus. These results represent that the studies are concentrated in case reports about paralytic strabismus, but this seems to be an area to be improved in future research.

Screening Strabismus of Elementary School (초등학생의 사시에 관한 연구)

  • Kim, Chang Sik;Lee, Hak Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.73-76
    • /
    • 1999
  • Screening of strabismus was followed in 1306 healthy elementary school students from 8 to 13 years old. The cover-uncover test with M1N GLASSES was used to screen strabismus for all of students and then we examined abnormal students by the prism cover test. Finally 16 students were strabismus. So the cover-uncover test with MIN GLASSES was a good method to screen strabismus because of easy and simple testing. The number of strabismus was 16 patients who consisted in from 10 to 13 years old, and girls(2.4%) was 3 times more than boys(0.9%). The type of 16 strabismus was only heterophoria which consisted in 8 patients of exophoria, 7 patients of esophoria and 1 patient of hyperphoria. So the rate of exophoria and esophoria was almost same. 3 patients was ametropic amblyopia by testing visual acuity, and all of patients were normal color vision by color testing.

  • PDF

Repeatability of New Phoria Test Using Color Chart and Color Filter (색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도)

  • Lee, Sun Haeng;Park, Sun-Young;Kim, Sang-Yoeb;Lee, Dong-Yeol;Kim, Kun-Kyu;Son, Jeong-Sik;Lee, Jae Yoon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.