Browse > Article

Repeatability of New Phoria Test Using Color Chart and Color Filter  

Lee, Sun Haeng (Department of Ophthalmic Optics, Gimhae College University)
Park, Sun-Young (Vision Institute of Song and Associates)
Kim, Sang-Yoeb (Department of Optometry, Kangwon National University)
Lee, Dong-Yeol (Department of Ophthalmic Optics, Daegu Science University)
Kim, Kun-Kyu (Department of Optometry, Sunlin University)
Son, Jeong-Sik (Department of Visual Optics, Kyungwoon University)
Lee, Jae Yoon (College of Engineering, Kangwon National University)
Cho, Hyun Gug (Department of Optometry, Kangwon National University)
Publication Information
Journal of Korean Ophthalmic Optics Society / v.15, no.3, 2010 , pp. 269-274 More about this Journal
Abstract
Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.
Keywords
Red-Blue Phoria Chart; Phoria Test; Repeatability;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Casillas E. and Rosenfield M., "Comparison of subjective heterophoria testing with a phoropter and trial frame", Optom. Vis. Sci., 86(4):237-241(2006).
2 Rainey B. B., Schroeder T. L., Goss D. A., and Grosvenor T. P., "Inter-examiner repeatability of heterophoria tests", Optom. Vis. Sci., 75(10):719-726(1998).   DOI   ScienceOn
3 윤동호, 이상욱, 최억, "안과학", 일조각, 서울, pp.200-227(1990).
4 이규병, 전순우, 이현주, 이선행, 박원빈, 마기중, 박수봉 "여러가지 사위 측정법의 비교 분석", 대한시과학회지, 9(1):115-125(2007).
5 Wong E. P. F., Fricke T. R., and Dinardo C., "Interexaminer repeatability of a new, modified prentice card compared with established phoria tests", Optom. Vis. Sci., 79(6):370-375(2002).   DOI   ScienceOn
6 Griffin J. R. and Grisham J. D., "Binocular Anomalies: Diagnosis and Vision Therapy", 4th Ed., Butterworth-Heinemann, Boston, pp. 78-85(1995).
7 Scobee R. G. and Green E. L., "Test for heterophoria: reliability of tests, comparisons between tests, and effect of changing testing conditions", Transactions of the American Academy of Ophthalmology & Otolaryngology, 51: 179-197(1947).
8 Bland J. M. and Altman D. G., "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 8:307-310(1986).
9 Elliott D. B., "Clinical procedures in primary eye care", 3rd ed., Butterworth-Heinemann, Philadelphia, pp. 169-174(2007).
10 Schroeder T. L., Rainey B. B., Goss D. A., and Grosvenor T. P., "Reliability of and comparisons among methods of measuring dissociated phoria", Optom. Vis. Sci., 73:389-397(1996).   DOI   ScienceOn
11 Hirsch M. J. and Bing L. B., "The effect of testing method on values obtained for phoria at forty centimeters", Am. J. Optom. Arch. Am. Acad. Optom., 25:407-416(1948).   DOI
12 Krger R. H. and Binder S., "Use of paper selectively absorbing long wavelengths to reduce the impact of educational near work on human refractive development", Br. J. Ophthalmol., 84:890-893(2000).   DOI   ScienceOn