• Title/Summary/Keyword: Hemodialysis system

Search Result 45, Processing Time 0.021 seconds

Improvement of Convection by Pulsatile Blood Pump in High Flux Hemodialysis System (고 유량 혈액 투석 시스템에서 박동류 펌프에 대한 대류 향상에 관한 연구)

  • Choi, D.S.;Um, K.M.;Lee, J.C.;Lee, S.R.;Mun, C.H.;Choi, H.;Min, B.G.;Kim, H.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.376-383
    • /
    • 2008
  • High-flux dialysis treatment removes various toxins via diffusion as well as convection, which is induced by ultrafiltration and backfiltration. In this study, in vitro (Using the distilled water and the bovine's blood) comparison test was performed to determine whether utilization of a high flux dialyzer paired with different pumps would increase the efficiency of convection. At the same blood flow rates, a pulsatile pump and a roller pump were employed to propel the distilled water and bovine whole blood to a high flux dialyzer. Pressures at the dialyzer inlet and outlet in the blood circuit and in the dialysate circuit were measured, respectively. From these data, we calculated the transmembrane pressure and predicted the ultrafiltration and backfiltration rates developed by both pumps. Using the bovine's blood experiment, ultrafiltration and backfiltration rates were 1.6 times higher with the pulsatile pump than with the roller pump. We conclude that utilization of a pulsatile pump in high flux hemodialysis treatments increases ultrafiltration volume, compared with a roller pump under conditions of the same blood flow rate.

Development of AI-based Hemodialysis machine monitoring system (AI 기반의 혈액투석기 모니터링 시스템 개발)

  • Kim, Hong-youn;Kim, Seu-hong;Piao, Hai-lian
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.282-283
    • /
    • 2022
  • 본 논문에서 기존의 혈액투석기는 회전하는 모터를 사용하여 구성하였으나 이러한 모터는 정밀도, 반복정밀도가 50um 이하로 가공물 가공시에 치기공사나 치과의사가 사람에 맞추어 다시 작업을 해야하는 불편함과 시간적, 작업자의 피로도를 높일수 있는데 이러한 모터에 스크류나 밸트를 연결하여 선형적으로 움직일 수 있는 리니어모듈과 리니어모터를 적용하게되면 20um수준의 고정밀의 위치 제어가 가능한 혈액투석기를 만들 수 있었다. 또한 MEMS센서를 이용하여 모터의 상태를 모니터링하고 임계값을 지정하여 이상 신호 발생시 모터를 멈추어 위험상황에 대해서 인공지능기법을 이용하여 정지하거나 관리자에게 알림을 주어 효과적으로 혈액투석기를 운영할 수 있도록 하였다.

A Case of Intoxication of Ingested Formalin (포르말린에 의한 급성 중독 1례)

  • Baek, Seon-Hee;Kim, Kyung-Hwan;Park, Jun-Seok;Shin, Dong-Wun;Roh, Jun-Young;Lee, Kyoung-Mi;Kim, Ah-Jin
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.7 no.1
    • /
    • pp.38-40
    • /
    • 2009
  • Formalin is a water-soluble, colorless, pungent, irritating and highly reactive gas. A 40% solution of formaldehyde in water, also known as formalin, is used as a disinfectant, antiseptic, deodorant, tissue fixative and embalming fluid. Ingestion can lead to immediate deleterious effects on almost all systems of the body including gastrointestinal tract, central nervous system, cardiovsacular system and hepato-renal system, causing gastrointestinal hemorrhage, cardiovsacular collapse, unconsciousness or convulsions, severe metabolic acidosis and acute respiratory distress syndrome. We treated a 39-year-old woman who ingested 300 ml formalin in a suicidal attempt. Despite hemodialysis, death occurred after 23 h.

  • PDF

A Case of Goodpasture's Syndrome with Normal Renal Function (정상 신기능을 보인 Goodpasture 증후군 1예)

  • Kim, Sung Kyoung;Lee, Jin Kook;Joo, Kyeo Rae;Hur, Sung Eun;Kim, Jeong Hoon;Kim, Young Kyoon;Lee, Sook Young;Kim, Seung Joon;Kim, Chi Hong;Song, So Hyang;Park, Sung Hark;Choi, Young Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.1
    • /
    • pp.86-92
    • /
    • 2005
  • Goodpasture's syndrome is a disease that is characterized by hemoptysis, anemia, and glomerulonephritis with renal failure. Goodpasture reported a case of a young man who expired as a result of a pulmonary hemorrhage and glomerulonephritis at the recovery phase after an influenza infection in 1919. In 1958, Stanton et al. described a combined case of these two diseases as Goodpasture's syndrome. Since then, antiglomerular basement membrane antibody(anti-GBM Ab) has been confirmed to play an important role in the mechanism of this syndrome, and it was reported that this syndrome was an autoimmune disease. The triad of alveolar hemorrhage, glomerulonephritis and circulating anti-GBM Ab forms the basis of a diagnosis of Goodpasture's syndrome. When patients are affected by disease, the relief of symptoms can be accomplished by eliminating the anti-GBM Ab from the circulatory system through hemodialysis, plasmapheresis and immunoabsorption. However, the patients usually die from a massive pulmonary hemorrhage when the diagnosis or treatment is delayed. The incidence of Goodpasture's syndrome is common in the western world, but it is extremely rare in Korea with only five cases being reported. In three of these cases, pulmonary hemorrhage and renal failure was the initial manifestation. Therefore, hemodialysis or plasmapheresis were absolutely essential treatments. We report a case of Goodpasture's syndrome in Korea with a normal renal function.

A Case Report of Central Nervous System Disorder Induced Intractable Hiccups Treated with Korean Medicine (중추신경계 질환자에게 이환된 난치성 딸꾹질의 한방치험1례)

  • Moon, Jiseong;Min, Seonwoo;Kim, Yeseul;Park, Jiyoon;Hong, Junghwa;Choi, Dong-jun
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.2
    • /
    • pp.191-200
    • /
    • 2022
  • Intractable hiccups are those which persist for more than one month and can often occur in patients with disorders of the central nervous system, such as stroke, epilepsy, or brain tumor. An 80-year-old male patient undergoing conservative hemodialysis for diabetic nephropathy, recently developed paralysis and dysphagia due to central nervous system complications including stroke and epilepsy. He was admitted to the ◯◯ Oriental Medicine Hospital, and treated with herbal medicine (Gyulpijugyeo-tang, Jeonssiigong-san, and Ijin-tang) and electrical acupuncture for 30 days. No side effects were observed during hospitalization. The frequency and duration of hiccups were measured daily and found to reduce, and the effect persisted during his admission. The patient took no other nervous system drugs. In conclusion, Korean medicine like gyulpijugyeo-tang and acupuncture can be effective for patients with intractable hiccups who cannot use alternative drugs or treatment, because of other complications.

A rare case of childhood-onset systemic lupus erythematosus associated end-stage renal disease with cerebral abscess and hemorrhage

  • Jee Hyun Kim;Jae Il Shin; Ji Hong Kim;Keum Hwa Lee
    • Childhood Kidney Diseases
    • /
    • v.28 no.1
    • /
    • pp.44-50
    • /
    • 2024
  • Systemic lupus erythematosus (SLE) is a chronic autoimmune inflammatory disease that affects multiple organs. More than half of the patients with SLE have kidney involvement, and up to 10% of patients with lupus nephritis develop end-stage renal disease (ESRD). Central nervous system (CNS) involvement in SLE occurs in 21% to 95% of patients. Severe neurological manifestations such as seizures, cerebrovascular disease, meningitis, and cerebrovascular accidents can develop in childhood-onset SLE, but cerebral infections, such as brain abscess and hemorrhage, are seldom reported in lupus nephritis, even in adults. Here, we report a rare case of childhood-onset SLE with ESRD, cerebral abscess, and hemorrhage. A 9-year-old girl diagnosed with lupus nephritis was administered high-dose steroids and immunosuppressant therapy to treat acute kidney injury (AKI) and massive proteinuria. The AKI deteriorated, and after 3 months, she developed ESRD. She received hemodialysis three times a week along with daily peritoneal dialysis to control edema. She developed seizures, and imaging showed a brain abscess. This was complicated by spontaneous cerebral hemorrhage, and she became unstable. She died shortly after the hemorrhage was discovered. In conclusion, CNS complications should always be considered in clinical practice because they increase mortality, especially in those with risk factors for infection.

The Influence of Hemosialysis to the Face Color of Patients in End Stage Renal Disease (말기신부전 환자의 혈액투석 치료가 안면 색에 미치는 영향)

  • Lee, Se-Hwan;Cho, Dong-Uk
    • The KIPS Transactions:PartB
    • /
    • v.17B no.6
    • /
    • pp.437-444
    • /
    • 2010
  • In this paper, we propose a method of analysing the relation between the patient's face color and his(her) kidney disease using image processing technology. This method is based on the ocular inspection which is one of the most famous diagnosis methods used in the oriental medical system. The way of processing and analysing the face image, which is for visualization and objectification of the color difference, is included. The objects are selected from the patients who suffer the kidney disease and use the hemodialyzer. Their facial images and clinical data are collected. From these data, we propose a hypothesis that the color of the patient's face is changed according to the patient's kidney state. At the same time, we present two algorithms of extracting the specific part of face which can identify the state of the patient's kidney and tracing the history of the color's change. This proposed method is evaluated through the practical experiments and their analysis.

A Microfluidic Chip-Based Creatinine Filtration Device (마이크로 플루이딕 칩을 기반으로 한 크레아티닌 여과장치)

  • Lee, Sack;Shin, Dong-Gyu;Nguyen, Thanh Qua;Park, Woo-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.921-925
    • /
    • 2015
  • The number of people suffering from renal disease increases every year. One of the most common treatments (clinical care options) for renal diseases is hemodialysis. However it takes a long time and has a high cost. Therefore, the importance of artificial kidney research has risen. Filtering creatinine from blood is one of the prime renal functions. Thus, we designed a novel two channel microfluidic chip focused on that function. In order to bond the individual polydimethylsiloxane layers, we have developed a housing system using acrylic plastic frame. This method has significant advantages in changing filter membranes. We use anodic aluminum oxide for the filter membrane. We analyzed the difference in the absorbance values for various creatinine concentrations using the Jaffe reaction. For the purpose of acquiring a standard equation to quantify the creatinine concentration, we interpolated the measured data and confirmed the concentration of the filtered solution. Through this experiment, we determined how the filtration efficiency depended on the flow rate and creatinine concentration.

A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design (감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로)

  • Han, Su Ha;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.