• Title/Summary/Keyword: Height/diameter ratio

Search Result 529, Processing Time 0.029 seconds

Cone Sex Ratio and Pollen Traits in Pinus densiflora (Pinaceae)

  • Kang, Hyesoon;Yoon, Jumsoon
    • Animal cells and systems
    • /
    • v.4 no.2
    • /
    • pp.131-140
    • /
    • 2000
  • The pattern of variations in cone sex ratio and pollen traits such as pollen number and size was examined for two years in populations of red pines In Korea. We evaluated; (1) the relationship between tree size and cone sex ratio, (2) the relationship between year and cone sex ratio, and (3) the relationship between cone sex ratio and pollen traits. Larger trees in height and circumference at breast height produced more male as well as female cones. However, cone sex ratio was independent of these plant sizes. Across the two populations, both female cone numbers per tree and male cone numbers per new shoot increased 2.2 and 1.2 times, respectively, in 1999 compared to 1998, while the yearly pattern of male cone-bearing shoots per tree differed significantly between populations. Thus, cone sex ratio varied significantly between years in one of the two populations. Pollen traits such as the number of pollen grains and diameter did not vary significantly among populations. Pollen diameter and grain numbers per male cone were significantly negatively correlated with the cone sex ratio in two populations and one population, respectively. Trees which stopped female cone production in the first year and those which produced female cones in both years differed in the cone sex ratio and pollen size in the second year. The long duration of one reproductive episode and the potential of masting in red pines emphasize the need to conduct long-term studies on the dynamics of cone production, cone sex ratio, and simultaneous changes in pollen traits in red pines.

  • PDF

Processing Study for the Micro Pillar for Piezoelectric Energy Harvest (압전 에너지 하베스트를 위한 마이크로 필라 공정 연구)

  • Yun, Seok-Woo;Lee, Ku-Tak;Lee, Kyoung-Su;Jeong, Soon-Jong;Kim, Min-Soo;Cho, Kyoung-Ho;Koh, Jung-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.601-604
    • /
    • 2010
  • In this study, the piezoelectric energy harvester was investigated employing the pillar structure with the diameter size of 50~500 um. Usually, the aspect ratio between the height and diameter was related with the piezoelectric performance. High aspect ratio was showed the low electric noise and high piezoelectric properties than low aspect ratio. Therefore, we have selected the Su-8 photo-resist and modified lithography process to manufacture the pillar structure with height above the 250 ${\mu}m$. In this presentation, we will report the process and properties of micro pillar structure based on the PMN-PZT (Pb$(Mg_{1/3}Nb_{2/3})O_3$-PbZrTiO$_3$) materials.

Characteristics of Heat Transfer in the Ribbed Rectangular Channel with Variable Heating Condition

  • Kim Won-Cheol;Putra Ary Bachtiar Krishna;Kang Ho-Keun;Ahn Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2007
  • Surface heat transfer of a fully developed turbulent air flow in a $45^{\circ}$ inclined ribbed square duct with two and four heating walls was experimentally investigated, at which the experimental works were performed for Reynolds numbers ranging from 7,600 to 24,900. The pitch-to-rib height ratio, p/e was kept at 8 and rib-height-to-channel hydraulic diameter ratio, $e/D_h$ was kept at 0.0667. The channel length-to-hydraulic diameter ratio, $L/D_h$ was 60. The heat transfer coefficient values were decreased with the increase in the number of heating walls. Results of this investigation could be used in various applications of internal channel turbulent flow involving roughened walls.

Pressure Drop Distributions in Rotating Channels with Turning Region and Angled Ribs (I) - Cross Rib Arrangements - (각도요철 및 곡관부를 가진 회전덕트 내 압력강하 분포 (I) - 엇갈린 요철 배열 -)

  • Kim, Kyung-Min;Park, Suk-Hwan;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.873-881
    • /
    • 2006
  • The present study investigates the pressure drop characteristics in rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter $(D_h)$ of 26.67mm. Rib turbulators are attached crossly in the four different arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of $2mm(e){\times}3mm(w)$ and an attack angle of $70^{\circ}C$. The pitch-to-rib height ratio (pie) is 7.5, and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.075. The results show that the highest pressure drop among each region appears in the turning region for the stationary case, but appears in the upstream region of the second pass for the rotating case. Effects of cross rib arrangements are almost the same in the first pass for the stationary and rotating cases. In the second pass, however, heat transfer and pressure drop are high for the cases with cross NN or PP type ribs in the stationary ducts. In the rotating ducts, they are high for the cases with cross NP or PP type ribs.

Pressure Drop Distributions in Rotating Channels with Turning Region and Angled Ribs (II) - Parallel Rib Arrangements - (각도요철 및 곡관부를 가진 회전덕트 내 압력강하 분포 (II) - 평행한 요철 배열 -)

  • Kim, Kyung-Min;Park, Suk-Hwan;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.882-890
    • /
    • 2006
  • The present study investigates the pressure drop characteristics in rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter $(D_h)$ of 26.67mm. Rib turbulators are attached parallel in the four different arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of $2m(e){\times}3mm(w)$ and an attack angle of $70^{\circ}C$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.075. The results show that the highest pressure drop among each region appears in the turning region for the stationary case, but appears in the upstream region of the second pass for the rotating case. Effects of parallel rib arrangements are almost the same in the first pass for the stationary and rotating cases. In the second pass, however, heat transfer and pressure drop are high for the cases with parallel NN or PP type ribs in the stationary ducts. In the rotating ducts, they are high for the cases with parallel NN or PN type ribs.

Heat Transfer Enhancement in a Divergent Passage with 30° Inclined Ribs (30° 경사 리브가 있는 확대 채널 통로 내의 열전달 증가)

  • Lee, Myung Sung;Ahn, Soo Whan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.401-407
    • /
    • 2017
  • The effect of different rib geometries such as V-shaped continuous (case A), parallel broken (case B), and V-shaped broken (case C) ribs on local heat transfer distributions and pressure drops in a divergent channel with $30^{\circ}$ inclined ribs on one wall or two walls was investigated for Reynolds numbers from 22,000 to 75,000. Top and bottom walls were insulated; two side walls were uniformly heated in the divergent channel. Heated walls were composed of 10 isolated coper sections and length-to-outlet hydraulic diameter ratio of 10. Rib height-to-outlet hydraulic diameter ratio was 0.1, and rib pitch-to-height ratio equaled 10. Results revealed that V-shaped continuous rib (case A) produced approximately 1.4 times higher average Nussselt number than in the parallel broken rib (case B), and V-shaped broken rib (case C) in the channel with two ribbed walls at Re = 54,000.

Utilization of Kenaf Cultivated in Korea(I) - Growth and Anatomical Characteristics of Kenaf Cultivated in Korea - (국내산 Kenaf 이용에 관한 연구(제1보) -국내에서 재배한 kenaf의 생장 및 해부학적 특성-)

  • 이명구;윤승락
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.4
    • /
    • pp.68-74
    • /
    • 2003
  • Kenaf(Hibiscus cannabinus L.) cultivar, Tainung 2, had been grown for 152 days at the experimental farm of Jinju National University, Gajoa-dong, Jinju-si, Kyongnam, Korea. The planting, growth rate, fertilization and structural characteristics as well as the cultivation and growth characteristics of kenaf, and the product usage were investigated. The narrowest diameter at kenaf bottom was 10 mm, the widest 42 mm and the average about 28 mm, and the shortest height 150 cm, the tallest 480 cm and the average about 350 cm. The weight of a core fraction was 68.1% and a bast fraction 31.9%. The weight ratio of core material to bast fiber was 2.31. The weight ratio of dry stem was 73.5% and that of leaves 26.5%. The weight of dry plant produced in 1 $m^2$ was 1,467 g, and about 1,052 g of stem could be used for the commercial purpose, The application of fertilizers resulted in the increase of the growth rate of the diameter at plant bottom and the height. Bast fiber, phloem ray and cortex parenchyma cell were observed in bast, and vessel, wood fiber and ray in core.

Effect of Number of Heating Walls on Heat Transfer in Ribbed Rectangular Channel (거친 사각채널에서 가열 벽면의 수가 열전달에 미치는 효과)

  • Bae Sung Taek;Ahn Soo Whan;Kim Myoung Ho;Lee Dae Hee;Kang Ho Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.514-520
    • /
    • 2005
  • Surface heat transfer of a fully developed turbulent air flow in a $45^{\circ}$ inclined ribbed square duct with two and four heating walls was experimentally investigated, at which the experimental works were peformed for Reynolds numbers ranging from 7,600 to 26,000. The pitch-to-rib height ratio, p/e, was kept at 8 and rib-height-to-channel hydraulic diameter ratio, $e/D_h$ was kept at 0.0667. The channel length-to-hydraulic diameter ratio, $L/D_h$ was 60. The heat transfer coefficient values were decreased with the increase in the number of heat-ing walls. Results of this investigation could be used in various applications of internal channel turbulent flow involving roughened walls.

Flow Around an Elliptic Cylinder Placed Near a Plane Boundary (평판 가까이에 놓인 타원형 실린더 주위 유동에 관한 연구)

  • Kim, Seong-Min;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.8
    • /
    • pp.2637-2649
    • /
    • 1996
  • Flow characteristics and aerodynamic forces acting on an elliptic cylinder placed in a plane boundary layer were investigated experimentally. Four cylinder models with axis ratio(major axis to minor axis, AR=A/B) of 1, 2, 3, and 4 having the same equivalent diameter were used in this experiment. The Reynolds number based on the equivalent diameter $D_e$(=20mm) was 13,000. In the case of circular cylinder, regular vortex shedding occurs for the cylinder gaps larger than G/B=0.3 and is not almost related to the boundary layer thickness. But, for the elliptic cylinders, the vortex shedding frequency is increased with increasing the gap ratio (G/B) and the axis ratio (AR) of elliptic cylinders. The maximum drag coefficient acting on a circular cylinder is mainly affected by the boundary layer thickness. But, the elliptic cylinders(AR$\geq$2), except for the smaller gap G/B<0.2, show a nearly constant drag coefficient which is much smaller than that of a circular cylinder. The base pressure on the flat plate decreases with increasing the axis ratio(AR) of the elliptic cylinder. In the case of a circular cylinder, the base pressure has the minimum value at the gap ratio G/B=0.4, but it occurs at G/D=2 for elliptic cylinders. The mean velocity of the cylinder wake is quickly recovered at a small cylinder height ratio(H/$\delta$), but the turbulent intensity is rapidly recovered at a large cylinder height ratio(H/$\delta$). The effective wake region in the plane boundary layer is shrinkaged with increasing the axis ratio(AR) of elliptic cylinder. And the drag coefficient and streamwise turbulent intensity of the elliptic cylinder with AR=4 are less than half of those for the circular cylinder(AR=1).

Effect of Height on CNT Aggregates Size and Shape in Freeboard Region of a Fluidized Bed (유동층 반응기 프리보드 내 높이에 따른 CNT 응집체 형상 변화)

  • Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.105-110
    • /
    • 2019
  • Effect of height on the size and shape of carbon nanotube (CNT) aggregates in the freeboard region of a bubbling fluidized bed ($0.15m\;i.d.{\times}2.6m\;high$) has been determined. Feret diameter and Heywood diameter of the CNT aggregates in the freeboard region of fluidized bed increased with increasing gas velocity. The average aggregate diameters and CNT particle number in the aggregates decreased with increasing of height in the freeboard. Aspect ratio increased as the location was closer to the surface of the dense phase, but decreased at the highest location. Solidity did not show any significant changes with height. The results showed the aggregates formation process is affected by the height in the freeboard. A correlation was proposed to predict the Heywood diameter of the CNT aggregates.