• 제목/요약/키워드: Heavy-impact Noise

검색결과 166건 처리시간 0.027초

표준실험동의 구조별 소음 진동 특성 (Noise and Vibration Characteristics of Construction structures in Standard Laboratory)

  • 정영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.390-393
    • /
    • 2005
  • In this study, examined heavy-weight floor impact sound to rahmen structure(steel reinforced concrete structure) and bearing-wall structure(box frame type structure) that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results of ANSYS modeling of structures was predicted that the nature natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Rahmen structures compares with bearing-wall structure, nature frequency was predicted low. Measurement results of natural frequency and acceleration level for structures at a standard laboratory, tendency department such as ANSYS modeling appeared. Rahmen structures appeared that reduction effect is less in Acceleration level and heavy impact sound transmission level comparing with bearing-wall structure.

  • PDF

슬래브 두께에 따른 표준실험동의 중량충격음 특성 (Heavy-weight Floor Impact Sound Characteristics of Standard Laboratory by Slab Thickness)

  • 정영;송희수;전진용;김진수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.103-108
    • /
    • 2004
  • In this study, examined heavy-weight floor impact sound to structure that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results show that the nature Natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Results of measurements of noise and vibration at a standard laboratory, the slab 210, 240mm structures was construed result such as finite element analysis but the slab 150, 180mm structures is construed that influence in vibration acceleration level because edge condition has condition that contact to ground. Therefore, in modelling process for analysis, is thought that need that condition analyzes examining element influencing about structure that contact to ground.

  • PDF

실 충격원에 대한 바닥마감재 성능 분석 (Performance of floor coverings by impact sound)

  • 정진연;임정빈;이성찬;김경우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석 (An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis)

  • 문대호;박홍근;황재승;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

완충재 유무에 따른 표준중량충격원에 의한 콘크리트 바닥 구조의 소음 및 진동 특성 (Noise and Vibration Characteristics of Concrete Floor Structures Using Resilient Materials Driven by Standard Heavy Impact Source)

  • 송희수;전진용;서상호
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.661-667
    • /
    • 2004
  • The characteristics of noise and vibration by a heavy impact source was studied. The triggering method was used for increasing the reliability and stability to measure the level of sound pressure. sound intensity and vibration acceleration. A simple finite element model and a rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The results show that the resilient materials decrease the natural frequency of the reinforced concrete slab, make a resonance with dominant driving frequency in the low frequency region, and increase the vibration and noise level. A simple finite element model and rigid body models was suggested to calculate the natural frequencies of the floor systems.

제진재가 삽입된 바닥 구조의 진동특성에 대한 실험연구 (Vibration Characteristics of the Floor Structures Inserted with Damping Materials)

  • 전진용;정영
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1036-1043
    • /
    • 2006
  • Damping materials for reducing heavy-weight floor impact noise in reinforced concrete structures were tested in apartment buildings. The effect of damping materials and an impact isolator were compared with an on-site experiment conducted in a high-rise apartment building. The loss factor of damping material analyzed more than 2 times than rubber to $1.5{\sim}2.3$, could know that Damping layer has excellent attenuation performance in side of vibration reduction. The results showed that the resonance frequency increased but vibration acceleration level decreased when the damping materials were used. The heavy-weight impact sound levels of the structure decreased substantially at 63 Hz, whereas the sound levels of the structure with the impact isolator increased.

중량 바닥충격음 예측을 위한 진동 전달률 산정 연구 (Assessment of Vibration Transmissibility for Prediction of Heavy Floor Impact Sound)

  • 김하근;김명준;오양기
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.415-422
    • /
    • 2003
  • In an apartment buildings, the floor Impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation, it is necessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to suggest the supplementary formula(equation) and constant k considering vibration transmissibility in order to predict more precisely heavy floor impact sound by Impedance Method that have been briskly studied in Japan from comparing the measured values with the predicted values. The analyzed results had showed that if the damping material was glass wool or rubber, k=5 was proper and if the damping material was polystyrene foam, k>5 was desirable.

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The Effect of Dynamic Property of Absorbing Sheet on the Amplification of Heavy Weight Floor Impact Noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.651-657
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50 dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6~7 dB compared to the conventional slab system at the optimal stud location.

임팩트 볼에 의한 중량 충격음의 Sound Quality 특성 (Sound quality characteristics of heavy-weight impact sounds generated by impact ball)

  • 유진;이혜미;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.671-674
    • /
    • 2006
  • Heavy-weight impact sounds generated by impact ball were classified according to the frequency characteristics on the equal loudness contours. Sound quality metrics such as Zwicker's loudness, sharpness, roughness of each classified impact sound were also measured. Loudness spectrum has been regarded as an indication of the characteristics difference of each classified impact sound. The adjectives in Korean expressing the sound quality characteristics of floor impact sounds were also investigated by adoptability and similarity tests. The group of the adjectives was used to evaluate the sound quality of floor impact sound by semantic differential test method.

  • PDF

바닥충격음레벨 영향요인 분석 (An Analysis of the Influence Factors of Floor Impact Sound Levels)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.255-260
    • /
    • 2003
  • The regulation for floor impact sound level is expected to be amended to 50㏈(L$\_$i, Fmax, AW/) and below in heavy-weight impact sound and 58㏈(L'$\_$n, AW/) and below in light-weight impact sound in Korea. The purpose of this paper is to analyze the influence factors of floor impact sound levels in apartments. The influence factors were air pressure of bang machine, height of microphones, data acquisition rate, etc. The air pressure range of bang machine were from 2.2 Pa to 2.6 Fa. Five microphones were installed at a height of 0.5m, 0.7m, 0.9m, 1.2m, 1.5m or 1.7m from floor level. The floor impact sound level was varied about 1-3㏈(L$\_$i, Fmax, AW/) in heavy-weight impact sound according to the influence factors.

  • PDF