• 제목/요약/키워드: Heating period

검색결과 539건 처리시간 0.029초

애주(艾炷)의 형태별(形態別) 연소(燃燒) 특성(特性)에 대한 연구(?究) - 연소온도(燃燒溫度)의 유형(類型)을 중심(中心)으로 - (An Experimental Study on the Characteristics of Moxa Combustion in the Moxa Cone size - On the Pattern of Combustion temperature -)

  • 박영배;강성길;김창환;고형균;오환섭;허웅
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.370-378
    • /
    • 1995
  • In order to consider the clinical efficacy of moxa combustion, understand the quality and quantity of heat stimulation and get the basic data for the development of electric moxibustion apparatus, the pattern of combustion temperature was measured by size of moxa(small, medium, large and maximum size). The results were as follows. 1. The pattern of combustion temperature by moxa burning was classified into input period, consisting of preheating and heating periods, and output period, consisting of heat retaining and cooling periods, in all experimental groups. But it was difficult to observe the preheating period in small sized moxa. 2. It was inclined that the more moxa size was large, the more the heating and heat retaining periods were long and the maximum temperature was high. The characteristics of moxa combustion is primarily by the rate of combustion temperature, gradient temperature and duration of combustion, and their correlation among these factors and their clinical effects in practice.

  • PDF

회암사지 온돌의 조성시기에 관한 연구 (Rethinking the Construction Period of the Ondol Heating System at Hoeamsa Monastery Site)

  • 임준구;김영재
    • 건축역사연구
    • /
    • 제31권1호
    • /
    • pp.19-28
    • /
    • 2022
  • The construction period of the ondol (Korean floor heating system) at Hoeamsa Temple Site is known as Joseon. The main reason is that a large number of remains in the Joseon era were excavated from the ondol floor with an all-around ondol method. This article partially accepts the theory of the creation of Ondol at Hoeamsa Temple Site during the Joseon Dynasty and suggests a new argument that some Ondol remains were built during the Goryeo Dynasty. The grounds for them are as follows. First, through the building sites consistent with the arrangement of the Cheonbosan Hoeamsa Sujogi (天寶山檜巖寺修造記, Record of Repair and Construction of Hoeamsa at Cheonbosan Mountain), it is highly likely that the ondol remains as a basic floor was maintained during the reconstruction period in Goryeo. Second, the all-around ondol method of the Monastery Site has already been widely used since the Goryeo Dynasty. Third, some ondol remains consist of "Mingaejari" and "Dunbeonggaejari," which were the methods of the gaejari (which dug deeper and stayed in the smoke) in the pre-Joseon Dynasty. Based on the above evidence, this study argues that the building sites such as Dongbangjangji, Seobangjangji, Ipsilyoji, Sijaeyoji, Susewaryoji, Seogiyoji, Seoseungdangji, Jijangryoji, and Hyanghwaryoji were constructed during the late Goryeo Dynasty.

남극 세종기지에서 복사 속 및 복사 가열률의 연직 분포 (The Vertical Distribution of Radiative Flux and Heating Rate at King Sejong Station in West Antarctica)

  • 이규태;이방용;이원학;지준범;이민경
    • Ocean and Polar Research
    • /
    • 제27권1호
    • /
    • pp.87-95
    • /
    • 2005
  • The vertical profiles of radiative flux and heating rate at King Sejong Station in West Antarctica were calculated with radiative transfe model by Chou and Suarez (1999) and Chou et al (2001). To run this model, the profiles of temperature, mixing ratios of water vapor and ozone at King Sejng Station were derived from ECMWF Reanalysis data. The surface temperature and albedo were also derived from NCEP/NCAR Reanalysis and CERES data. The radiative flux strongly depends on the cloud optical path length that was calculated using the measured W-h data and model by Chou and Lee(1996). Durins the period of $2000{\sim}2001$ (12 and 18 UTC), the correlation coefficient between calculated and measured downward solar fluxes at surface was 0.90 and the coefficient for downward longwave flux was 0.61. The calculated net heating rates of surface layer decreased during the same period, the trend of which was in accordance with the decrease of measured temperature.

알칼리 정제(精製)와 에스테르화에 의한 미강유의 열안정성(熱安定性)의 비교(比較) (Comparison of Thermal Stability of Alkali Refined and Esterified Rice Bran Oils)

  • 김현구;신동화;신효선
    • 한국식품과학회지
    • /
    • 제17권3호
    • /
    • pp.180-185
    • /
    • 1985
  • 알칼리 처리와 글리세린으로 에스테르화 반응을 시킨 탈산공정에 의하여 정제한 각 미강유의 열안정성을 비교하였다. 가열중 산 값의 변화는 알칼리정제 미강유에서는 가열시간에 따라서 증가하였으나, 글리세린처리 미강유의 일부는 완만한 증가추세를, 또 일부는 가열시간이 경과함에 따라서 산 값이 감소하였다. 과산화물 값의 변화는 가열중 증가와 감소의 반복추세를 나타냈으며 알칼리 정제 미강유와 글리세린처리 미강유의 과산화물 값이 13.3 mgq/kg하였다. TBA값의 변화는 가열 10시간까지 급격하게 증가하고 그후 완만한 감소추세를 나타낸다. 가열중 글리세린처리 미강유는 착색현상이 심하였다. 알칼리정제 미강유와 글리세린 미강유의 90시간 가열 후 TG의 감소율은 $150^{\circ}C$에서는 처리방법에 따라 큰 차이가 없었으나, $150^{\circ}C$에서는 글리세린처리미강유가 알칼리정제 미강유보다 TC의 감소율이 약 2${\sim}$7% 높았다. AOM 시험에서 알칼리 정제미강유는 글리세린처리미강유보다 약 2배의 산화 안정성이 있었다.

  • PDF

18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색 (A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society)

  • 정정남
    • 건축역사연구
    • /
    • 제27권3호
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

식용유(食用油)(해바라기)의 저장후건(貯藏候件)에 따른 지질성분(脂質成分)의 변화(變化) (Changes in the Lipid Components of Edible Oil (Sunflower Seed Oil) under Storage Conditions)

  • 황주호;윤형식
    • 한국식품영양과학회지
    • /
    • 제10권1호
    • /
    • pp.17-25
    • /
    • 1981
  • 국내산(國內産) 해바라기 종자유(種子油)를 사용(使用)하여 가열산화(加熱酸化)에 의(依)한 변화(變化)를 검토(檢討)하기 위하여 지방산조성(脂肪酸組成) 및 중성지질성분(中性脂質成分)의 변화(變化)와 특성(特性)을 측정(測定)한 결과(結果)는 다음과 같다. 종자유(種子油) 중에는 중성지질(中性脂質), 당지질(糖脂質) 및 인지질(燐脂質)의 함량(含量)은 각각(各各) 94.1%, 3.2% 및 2.7%였다. 지방산조성(脂肪酸組成)은 채유직후(採油直後) oleic acid가 59.84%로 가장 많고 linoleic acid는 29.48%로 그 다음으로 많으며 palmitic 및 stearic acid가 각각(各各) 6.21% 및 4.50%였다. 이는 외국(外國)에서 생산(生産)되는 종자유(種子油)와 비교(比較)하면 linoleic acid가 $20{\sim}30%$ 낮은 반면(反面)에 oleic acid는 $20{\sim}30%$정도 높았다. 처리후(處理後) linoleic acid 함량(含量)은 $100^{\circ}C$, $180^{\circ}C$에서 각각(各各) 1.48%, 5.32% 감소(減少)되었으나, oleic, palmitic 및 stearic acid는 상대적(相對的)으로 증가(增加)하였다. 또한 중성지질(中性脂質) 성분(成分)은 triglyceride, diglyceride 및 free fatty acid등(等)의 함량순(含量順)으로 6개(個)의 성분(成分)을 확인 하였고 처리후(處理後)에 있어서는 triglyceride는 감소(減少)한 반면(反面)에 diglyceride 및 monoglyceride는 증차증가(漸次增加)하였다. 또한 free fatty acid는 $100^{\circ}C$에서 점차(漸次) 증가(增加)하였으나 $180^{\circ}C$ 16시간(時間) 이후(以後)에는 약간의 감소(減少)를 보였다. 옥도가(沃度價)는 처리후(處理後) 감소(減少)하였으며, 과산화물가(過酸化物價)는 $100^{\circ}C$에서 점차(漸次) 계속 증가(增加)하였으나. $180^{\circ}C$에서는 16시간(時間) 까지는 증가(增加)하였으나 그이후(以後) 감소현상(減少現象)을 나타내었다.

  • PDF

기후 온난화의 영향에 의한 건물의 냉.난방에너지 수요량 예측 (The Demand Expectation of Heating & Cooling Energy in Buildings According to Climate Warming)

  • 김지혜;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.119-125
    • /
    • 2006
  • The impacts of climate changes on building energy demand were investigated by means of the degree-days method. Future trends for the 21st century was assessed based on climate change scenarios with 7 global climate models(GCMs). We constructed hourly weather data from monthly temperatures by Trnsys 16. A procedure to estimate heating degree-days (HDD) and cooling degree-days (CDD) from monthly temperature data was developed and applied to three scenarios for Inchon. In the period 1995-2080, HDD would fall by up to 70%. A significant increase in cooling energy demand was found to occur between 1995-2004(70% based on CDD). During 1995-2080, CDD would Increase by up to 120%. Our analysis shows widely varying shifts in future energy demand depending on season. Heating costs in winter will significantly decrease whereas more expensive electrical cooling energy will be needed.

6 kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제2보 모델링 및 시뮬레이션) (Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 2 : Modelling and Simulation))

  • 최봉수;김진홍;강용태;홍희기
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.556-565
    • /
    • 2004
  • We have experimented an actual solar water heating system acquiring real data for one year period. On the basis of the operation data, it is necessary to predict the system performance such as collector efficiency and solar fraction, and to analyze the economical efficiency for system optimal design. To estimate the performance of actual systems through simulation, valid modelling for components consisting of the system should be accompanied. The present study is focused on the modelling for load patterns and operating control conditions. We proposed two load models: concentration model which gathers real loads as a meaningful group and distribution model which disperses real loads with time. If grouping of the load distribution is suitable, the predicted values by the concentration model approaches to those by the distribution model close to actual load pattern apparently. As a result, both of them are in good agreement with those by experiment.

바닥 난방을 사용하는 주택내 거실 온열 환경의 실태조사 -서울과 동경의 사례조사 - (A Research on the Indoor Thermal Environment in Livingroom with Radiant Floor Heating System - Casestudy in Korea and Japan -)

  • 전정윤
    • 한국주거학회논문집
    • /
    • 제16권1호
    • /
    • pp.11-16
    • /
    • 2005
  • The purpose of this study is to find out the present thermal environment of the Korean livingroom in comparison with the Japan's. Thermal environment of the livingroom with radiant floor heating system in Korea and Japan is analysed. The surveys and measurements are took place in two detached houses and two apartments in Seoul, Korea and two apartments in Tokyo, Japan for a 48-hour period at the beginning of March, 2003. The result of this study shows that the thermal environment of the livingroom in Korean houses, especially in the apartments is warmer and stabler than the Japan's. However, despite of its high temperature, Koreans have a tendency to rise their room temperature creating excess.

마이크로히터에서 반주기 정현곡선의 열부하에 의한 비정상 열전달 연구 (NUMERICAL STUDY OF UNSTEADY HEAT TRANSFER ON MICRO HEATER UNDER HALF-CYCLE SINUSOIDAL HEAT LOAD)

  • 김명준;이희준
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2014
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under a sinusoidal heat load was conducted. It was found that the time constant is not affected by the maximum heating magnitude of the sinusoidal heat load. However, the time constant increases with low duration of the sinusoidal heating period and low Reynolds number. Moreover, there is a threshold where a heater temperature do not reach to time constant at low thermal diffusivity, low flow rate, and low pulse duration of the sinusoidal heating. The time constant should be considered for transient convective heat transfer under transient sinusoidal heat load in a micro heat sink.