• Title/Summary/Keyword: Heating period

Search Result 539, Processing Time 0.03 seconds

An Experimental Study on the Characteristics of Moxa Combustion in the Moxa Cone size - On the Pattern of Combustion temperature - (애주(艾炷)의 형태별(形態別) 연소(燃燒) 특성(特性)에 대한 연구(?究) - 연소온도(燃燒溫度)의 유형(類型)을 중심(中心)으로 -)

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Oh, Hwan-Sup;Huh, Wung
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.370-378
    • /
    • 1995
  • In order to consider the clinical efficacy of moxa combustion, understand the quality and quantity of heat stimulation and get the basic data for the development of electric moxibustion apparatus, the pattern of combustion temperature was measured by size of moxa(small, medium, large and maximum size). The results were as follows. 1. The pattern of combustion temperature by moxa burning was classified into input period, consisting of preheating and heating periods, and output period, consisting of heat retaining and cooling periods, in all experimental groups. But it was difficult to observe the preheating period in small sized moxa. 2. It was inclined that the more moxa size was large, the more the heating and heat retaining periods were long and the maximum temperature was high. The characteristics of moxa combustion is primarily by the rate of combustion temperature, gradient temperature and duration of combustion, and their correlation among these factors and their clinical effects in practice.

  • PDF

Rethinking the Construction Period of the Ondol Heating System at Hoeamsa Monastery Site (회암사지 온돌의 조성시기에 관한 연구)

  • Lim, Jun-Gu;Kim, Young-Jae
    • Journal of architectural history
    • /
    • v.31 no.1
    • /
    • pp.19-28
    • /
    • 2022
  • The construction period of the ondol (Korean floor heating system) at Hoeamsa Temple Site is known as Joseon. The main reason is that a large number of remains in the Joseon era were excavated from the ondol floor with an all-around ondol method. This article partially accepts the theory of the creation of Ondol at Hoeamsa Temple Site during the Joseon Dynasty and suggests a new argument that some Ondol remains were built during the Goryeo Dynasty. The grounds for them are as follows. First, through the building sites consistent with the arrangement of the Cheonbosan Hoeamsa Sujogi (天寶山檜巖寺修造記, Record of Repair and Construction of Hoeamsa at Cheonbosan Mountain), it is highly likely that the ondol remains as a basic floor was maintained during the reconstruction period in Goryeo. Second, the all-around ondol method of the Monastery Site has already been widely used since the Goryeo Dynasty. Third, some ondol remains consist of "Mingaejari" and "Dunbeonggaejari," which were the methods of the gaejari (which dug deeper and stayed in the smoke) in the pre-Joseon Dynasty. Based on the above evidence, this study argues that the building sites such as Dongbangjangji, Seobangjangji, Ipsilyoji, Sijaeyoji, Susewaryoji, Seogiyoji, Seoseungdangji, Jijangryoji, and Hyanghwaryoji were constructed during the late Goryeo Dynasty.

The Vertical Distribution of Radiative Flux and Heating Rate at King Sejong Station in West Antarctica (남극 세종기지에서 복사 속 및 복사 가열률의 연직 분포)

  • Lee, Kyu-Tae;Lee, Bang-Yong;Lee, Won-Hak;Jee, Joon-Bum;Lee, Min-Kyung
    • Ocean and Polar Research
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2005
  • The vertical profiles of radiative flux and heating rate at King Sejong Station in West Antarctica were calculated with radiative transfe model by Chou and Suarez (1999) and Chou et al (2001). To run this model, the profiles of temperature, mixing ratios of water vapor and ozone at King Sejng Station were derived from ECMWF Reanalysis data. The surface temperature and albedo were also derived from NCEP/NCAR Reanalysis and CERES data. The radiative flux strongly depends on the cloud optical path length that was calculated using the measured W-h data and model by Chou and Lee(1996). Durins the period of $2000{\sim}2001$ (12 and 18 UTC), the correlation coefficient between calculated and measured downward solar fluxes at surface was 0.90 and the coefficient for downward longwave flux was 0.61. The calculated net heating rates of surface layer decreased during the same period, the trend of which was in accordance with the decrease of measured temperature.

Comparison of Thermal Stability of Alkali Refined and Esterified Rice Bran Oils (알칼리 정제(精製)와 에스테르화에 의한 미강유의 열안정성(熱安定性)의 비교(比較))

  • Kim, Hyun-Ku;Shin, Dong-Hwa;Shin, Hyo-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.180-185
    • /
    • 1985
  • The alkali refined rice bran oil (ARBO) and the esterified rice bran oil (ERBO) with glycerol were compared for their thermal stabilities at $150^{\circ}C$ and $180^{\circ}C$, respectively. The acid value gradually increased in ARBO during heating period but increased slowly in ERBO-2 and declined gradually in ERBO-1. The peroxide value was somewhat fluctuated during heating period, and the maximum peroxide value in all samples was 13.3 meq/kg. TBA value was sharply increased for the first 10 hr. heating and slowed down thereafter for all samples but ERBO were intensely colored after the heat treatment. The TG ratio of the oils after 90 hr. heating was not different at $150^{\circ}C$ but ERBO was 2-7% higher ratio of TG than ARBO at $180^{\circ}C$. The oxidative stability of ARBO was twice higher than ERBO according to the result of active oxygen test.

  • PDF

A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society (18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색)

  • Chung, Jung-Nam
    • Journal of architectural history
    • /
    • v.27 no.3
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

Changes in the Lipid Components of Edible Oil (Sunflower Seed Oil) under Storage Conditions (식용유(食用油)(해바라기)의 저장후건(貯藏候件)에 따른 지질성분(脂質成分)의 변화(變化))

  • Hwang, Joo-Ho;Yoon, Hyung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.10 no.1
    • /
    • pp.17-25
    • /
    • 1981
  • The purpose of this study was to determine effects of thermal oxidation according to heating time and temperature, using sunflower oil from seed grown in Korea. To investigate these effects, the lipid components, fatty acid compositions, and chemical characteristics of crude oil from sunflower seed were determined. The content of nonpolar and polar in total lipids was 94.1% and 5.9%, respectively. The fatty acid compositions in the total lipids showed 6.21% palmitic, 4.50% stearic, 59.84% oleci and 29.48% linoleic acid. The concent of linoleic acid decreased during heating. However, the concent of oleic, palmitic and stearic acid increased during heating. The components of neutral lipid were found 6 fractions, including triglyceride, diglyceride and free fatty acid. The content of triglyceride decreased but diglyceride and monoglyceride increased during heating. The content of free fatty acid increased during the continuous heating period for 32 hours at $100^{\circ}C$, whereas decreased in 16 hours at $180^{\circ}C$. Iodine value decreased during heating, and peroxide value increased during the continuous heating period for 32 hours at $100^{\circ}C$, whereas decreased in 16 hours at $180^{\circ}C$.

  • PDF

The Demand Expectation of Heating & Cooling Energy in Buildings According to Climate Warming (기후 온난화의 영향에 의한 건물의 냉.난방에너지 수요량 예측)

  • Kim, Ji-Hye;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.119-125
    • /
    • 2006
  • The impacts of climate changes on building energy demand were investigated by means of the degree-days method. Future trends for the 21st century was assessed based on climate change scenarios with 7 global climate models(GCMs). We constructed hourly weather data from monthly temperatures by Trnsys 16. A procedure to estimate heating degree-days (HDD) and cooling degree-days (CDD) from monthly temperature data was developed and applied to three scenarios for Inchon. In the period 1995-2080, HDD would fall by up to 70%. A significant increase in cooling energy demand was found to occur between 1995-2004(70% based on CDD). During 1995-2080, CDD would Increase by up to 120%. Our analysis shows widely varying shifts in future energy demand depending on season. Heating costs in winter will significantly decrease whereas more expensive electrical cooling energy will be needed.

Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 2 : Modelling and Simulation) (6 kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제2보 모델링 및 시뮬레이션))

  • 최봉수;김진홍;강용태;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.556-565
    • /
    • 2004
  • We have experimented an actual solar water heating system acquiring real data for one year period. On the basis of the operation data, it is necessary to predict the system performance such as collector efficiency and solar fraction, and to analyze the economical efficiency for system optimal design. To estimate the performance of actual systems through simulation, valid modelling for components consisting of the system should be accompanied. The present study is focused on the modelling for load patterns and operating control conditions. We proposed two load models: concentration model which gathers real loads as a meaningful group and distribution model which disperses real loads with time. If grouping of the load distribution is suitable, the predicted values by the concentration model approaches to those by the distribution model close to actual load pattern apparently. As a result, both of them are in good agreement with those by experiment.

A Research on the Indoor Thermal Environment in Livingroom with Radiant Floor Heating System - Casestudy in Korea and Japan - (바닥 난방을 사용하는 주택내 거실 온열 환경의 실태조사 -서울과 동경의 사례조사 -)

  • Chun Chung-Yoon;Mitamura Teruaki;Fukai Kazoo
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • The purpose of this study is to find out the present thermal environment of the Korean livingroom in comparison with the Japan's. Thermal environment of the livingroom with radiant floor heating system in Korea and Japan is analysed. The surveys and measurements are took place in two detached houses and two apartments in Seoul, Korea and two apartments in Tokyo, Japan for a 48-hour period at the beginning of March, 2003. The result of this study shows that the thermal environment of the livingroom in Korean houses, especially in the apartments is warmer and stabler than the Japan's. However, despite of its high temperature, Koreans have a tendency to rise their room temperature creating excess.

NUMERICAL STUDY OF UNSTEADY HEAT TRANSFER ON MICRO HEATER UNDER HALF-CYCLE SINUSOIDAL HEAT LOAD (마이크로히터에서 반주기 정현곡선의 열부하에 의한 비정상 열전달 연구)

  • Kim, M.J.;Lee, H.J.
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under a sinusoidal heat load was conducted. It was found that the time constant is not affected by the maximum heating magnitude of the sinusoidal heat load. However, the time constant increases with low duration of the sinusoidal heating period and low Reynolds number. Moreover, there is a threshold where a heater temperature do not reach to time constant at low thermal diffusivity, low flow rate, and low pulse duration of the sinusoidal heating. The time constant should be considered for transient convective heat transfer under transient sinusoidal heat load in a micro heat sink.